Kii Fios First Entry CFF74Recalls & reported problems
Applied Medical Resources Corporation · Trocar · Class 2
All models of Kii Fios First Entry (18)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00607915117665), received between Jun 13, 2016 and Jun 13, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 13, 2016Material Fragmentation; Material Fragmentation
APPENDICITIS - "CHARGE NURSE STATED THAT DR. (B)(6) HAD A DIFFICULTY ADVANCING THE 45MM STAPLER THROUGH THE 12MM TROCAR, THEY HEARD A POPPING SOUND THEN THE INSTRUMENT WAS ABLE TO PASS THROUGH THE TROCAR, AFTER THE APPENDIX WAS TAKEN OUT, THEY GAVE PATIENT THE TRACAR AND A SMALL PIECE OF PLASTIC THEY THOUGHT WAS A PART THAT BROKE OFF DURING THE POPPING SOUND, AFTER INSPECTING THE TROCAR, THE SMALL BLACK PLASTIC WAS CONFIRMED AS A PART OF THE TROCAR'S AIR LOCKING SYSTEM AND NO OTHER PARTS ARE MISSING FROM THE TROCAR, SURGEON AND SCRUB TECH ALSO CONFIRMED THE PIECE AND THAT NO OTHER PARTS ARE LEFT INSIDE THE PATIENT." PATIENT STATUS - GOOD CONDITION
Patient problems: No Consequences Or Impact To Patient
MAUDE report 5720868 ↗
Other Laparoscope, General & Plastic Surgery devices
- HIGH DEFINITION LCD MONITOR OEV262HOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,937 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-12EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,886 reports
- HD AUTOCLAVABLE CAMERA HEAD OTV-S7ProH-HD-10EOlympus Medical Systems Corp. · Laparoscope, general & plastic surgery1,086 reports
- Auto Suture OMS-T10BTCovidien LP · Laparoscope, general & plastic surgery1 recall955 reports
- PDB OMS-PDB1000Covidien LP · Laparoscope, general & plastic surgery859 reports
- VISERA 4K UHD CAMERA CONTROL UNIT OLYMPUS OTV-S400Olympus Medical Systems Corp. · Laparoscope, general & plastic surgery777 reports
- Auto Suture OMS-T10SBCovidien LP · Laparoscope, general & plastic surgery1 recall697 reports
- Spacemaker SMBTTRNDXCovidien LP · Laparoscope, general & plastic surgery590 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page