EasyPoint® 82091Recalls & reported problems
Retractable Technologies, Inc. · 25G x 5/8" EasyPoint® Needle · Class 2
All models of EasyPoint (3)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 15
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 00613703820907), received between Jul 17, 2018 and May 1, 2024 — classified as 1 injury, 14 malfunctions.
The most frequently reported specific device problem is “Retraction Problem” (6 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Recalls naming this device
- Feb 5, 2024Class IIOpen, Classified
The needle cannula of a retractable needle may detach from the needle holder in the patient.
Z-1293-2024 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Retraction Problem6
- Break2
- Detachment of Device or Device Component1
- Fail-Safe Did Not Operate1
- Material Separation1
- Mechanical Jam1
- Output Problem1
- Unintended Ejection1
Patient problems
- No Known Impact Or Consequence To Patient8
- Insufficient Information3
- Device Embedded In Tissue or Plaque1
- Foreign Body In Patient1
- Needle Stick/Puncture1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 1, 2024
REGISTERED NURSE (RN) ADMINISTERED SC HEPARIN AS ORDERED. WHEN SHE RETRACTED NEEDLE AFTER ADMINISTRATION, NEEDLE REMAINED IN PATIENT'S ABDOMEN.
Patient problems: Foreign Body In Patient
MAUDE report 19220467 ↗MalfunctionMar 18, 2024
WHILE DRAWING UP HEPARIN THE NEEDLE CAME OUT OF THE RETRACTABLE HUB. THE NEEDLE WAS STUCK IN THE VIAL.
Patient problems: Insufficient Information
MAUDE report 18920631 ↗MalfunctionMar 18, 2024
RN PULLED AN EASYPOINT 25G NEEDLE OUT OF THE SUPPLY CART AND NOTICED THE ORIGINAL NEEDLE INTACT INSIDE THE SAFETY CAP, AS WELL AS AN EXTRA LOOSE NEEDLE INSIDE OF THE PACKAGING.
Patient problems: Insufficient Information
MAUDE report 18920629 ↗MalfunctionJan 24, 2024
RN WENT TO ENGAGE SAFETY MECHANISM OF INTRAMUSCULAR NEEDLE AND THE ENTIRE INTRAMUSCULAR NEEDLE TOP FELL APART INTO MANY PIECES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18571315 ↗InjuryJan 18, 2024Material Separation; Material Separation
INITIAL REPORT OF NEEDLE SEPARATION IN PATIENT WAS SUBMITTED BY VACCINE MANAGER OF USER FACILITY ON NOVEMBER 9, 2023. THE INITIAL INFORMATION WAS REPORTED AS FOLLOWS: NURSE GAVE FLUE VACCINE IN CHILD'S THIGH. WHEN SHE WENT TO RETRACT THE NEEDLE IT WENT INSIDE OF THE PATIENT'S THIGH. THE PATIENT WENT TO HOSPITAL AND HAD TO HAVE IT REMOVED VACCINE MANAGER REPORTED THAT FACILITY DID NOT RETAIN INVOLVED PRODUCT BUT HAD ASSOCIATED PRODUCT. SHIPPING CONTAINERS WERE SENT FOR RETURN OF ASSOCIATED PRODUCT AND RECEIPT WAS CONFIRMED ON NOVEMBER 17, 2023. NOVEMBER 17, 2023 REPORTING VACCINE MANAGER TO FOLLOW UP REGARDING TREATMENT AND OUTCOME OF PATIENT INVOLVED IN THE INCIDENT. ASSOCIATED PRODUCT WAS RECEIVED AND TESTING WAS COMPLETED ON DECEMBER 28, 2023. ALL SAMPLES RETURNED WERE TESTED AND WERE WITHIN SPECIFICATION. VACCINE MANAGER PROVIDED FOLLOW UP INFORMATION ON NOVEMBER 29, 2023 STATING THAT THE PATIENT'S MOTHER RETURNED TO THE HOSPITAL AND THE NEEDLE WAS SURGICALLY REMOVED BY THE HOSPITAL. THE SAME DAY VACCINE MANAGER PROVIDED AN IMAGE OF A DETACHED NEEDLE, AN XRAY OF NEEDLE IN PATIENT'S THIGH AND AN XRAY THAT SHOWS NO NEEDLE. ON DECEMBER 19, 2023 THE VACCINE MANAGER REPORTED THAT NO
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 18539548 ↗MalfunctionApr 7, 2023Break
WHILE ADMINISTERING SUBCUTANEOUS HEPARIN, REGISTERED NURSE ATTEMPTED TO RETRACT THE NEEDLE. THE SAFETY NEEDLE BROKE OFF.
Patient problems: Insufficient Information
MAUDE report 16701379 ↗MalfunctionJul 22, 2022Retraction Problem
RETRACTING NEEDLE DID NOT OPERATE CORRECTLY CAUSING RN TO STICK HERSELF.
Patient problems: Needle Stick/Puncture
MAUDE report 15084187 ↗MalfunctionNov 13, 2019Break; Unintended Ejection
AFTER ADMINISTERING FLU VACCINE, NEEDLE SAFETY DEVICE ACTIVATED BY PRESSING ORANGE BUTTON, NEEDLE SHOT INTO AIR AND BOTH HUB AND NEEDLE MECHANISM BROKE INTO PIECES. PIECES WERE ABLE TO BE RECOVERED AND NO ONE WAS HURT OR HIT BY ANY OF THE PIECES.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9314669 ↗MalfunctionJun 18, 2019Output Problem; Fail-Safe Did Not Operate
PATIENT WAS GIVEN THE SQ HEPARIN INJECTION AND SAFETY NEEDLE WOULD NOT FUNCTION. NURSE TRIED TO ACTIVE THE SAFETY MECHANISM 3 TIMES WITHOUT SUCCESS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8707109 ↗MalfunctionJun 4, 2019Retraction Problem
RN WAS GIVING THE PATIENT HIS EVENING HEPARIN INJECTION SQ IN THE LOWER LEFT QUADRANT OF THE ABDOMEN. ONCE THE HEPARIN WAS INSTILLED, RN WENT TO RETRACT THE NEEDLE UTILIZING THE BUTTON ON THE EASYPOINT 25G X 5/8" NEEDLE AND THE BUTTON DID NOT RETRACT. THE NEEDLE WAS RETRACTED MANUALLY FROM THE PATIENT'S INJECTION SITE. AFTER A SECOND ATTEMPT TO CLICK THE BUTTON ON THE EASYPOINT NEEDLE, THE SPRING FINALLY RELEASED AND THE NEEDLE RETRACTED BACK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8666563 ↗MalfunctionMar 12, 2019Retraction Problem
RN WAS ADMINISTERING SC HEPARIN INJECTION TO PATIENT AND SAFETY NEEDLE DID NOT RETRACT. RN NOTICED ON REMOVING THE HEPARIN SYRINGE THAT NEEDLE WAS NOT RETRACTED. NEITHER RN NOR PATIENT WERE STUCK BY NEEDLE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8412081 ↗MalfunctionMar 4, 2019Retraction Problem
RETRACTABLE NEEDLE DID NOT RETRACT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8385885 ↗MalfunctionJan 30, 2019Detachment of Device or Device Component; Mechanical Jam
THIS REGISTERED NURSE WENT TO ADMINISTER HEPARIN WITH RETRACTABLE NEEDLE ATTACHMENT. WHEN ATTEMPTING TO USE SAFETY LOCK, LOCK FELT JAMMED AND UNABLE TO USE APPROPRIATELY. TOOK NEEDLE OUT OF PATIENT'S ABDOMEN AND ATTEMPT TO SAFETY LOCK AWAY FROM PATIENT. AT THAT POINT NEEDLE AND SPRING FROM SAFETY LOCK FLEW ACROSS ROOM. ALL PARTS FOUND AND COLLECTED AND PRESENTED TO MANAGER IN STERILE CUP.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8288284 ↗MalfunctionOct 22, 2018Retraction Problem
THIS RN ADMINISTERED SUBQ HEPARIN UTILIZING THE "EASY POINT NEEDLE 25GX5/8"" RETRACTABLE. NEEDLE WAS INJECTED AND THE BUTTON WAS PRESSED WHILE NEEDLE WAS STILL INSIDE PATIENT TO RETRACT THE NEEDLE, BUT WHEN THIS RN MOVED HER HAND THE NEEDLE WAS STILL EXPOSED EVEN THOUGH IT "RETRACTED" WHEN THE ORANGE BUTTON WAS PRESSED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7989869 ↗MalfunctionJul 17, 2018Retraction Problem
RN GAVE PATIENT A HEPARIN SHOT USING EASY POINT NEEDLE 25G X 5/8" AND IT DID NOT RETRACT AFTER USE WHEN DEPRESSED. IT DID RETRACT AS RN PLACED IT IN THE SHARPS CONTAINER AND NEEDLE TOUCHED EDGE OF CONTAINER.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7693747 ↗
FDA clearance and classification
Cleared through 510(k) K133635 on Jun 17, 2014 (decision: Substantially Equivalent). Submitted by Retractable Technologies, Inc. as “Easypoint Needle”. The FDA review took 203 days. FDA record ↗
The FDA regulates product code FMI (needle, hypodermic, single lumen) under 21 CFR 880.5570 as a Class II device. 21 CFR 880.5570 ↗
Common questions about the EasyPoint® 82091
Has the EasyPoint® 82091 been recalled?
Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1293-2024 (Class II), began on Feb 5, 2024: The needle cannula of a retractable needle may detach from the needle holder in the patient. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.
What problems have been reported with the EasyPoint® 82091?
The FDA's MAUDE database lists 15 adverse event reports for this device, received between Jul 17, 2018 and May 1, 2024. In those reports, the most common specific device problems are “Retraction Problem” (6), “Break” (2) and “Detachment of Device or Device Component” (1); the most common patient problems are “Device Embedded In Tissue or Plaque” (1), “Foreign Body In Patient” (1) and “Needle Stick/Puncture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the EasyPoint® 82091?
None of the reports are classified as deaths, 1 as an injury and 14 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the EasyPoint® 82091 FDA approved?
It was cleared through 510(k) K133635 on Jun 17, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the EasyPoint® 82091, and is it still sold?
The FDA's device database lists Retractable Technologies, Inc. as the company responsible for it (brand EasyPoint®, model 82091). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Needle, Hypodermic, Single Lumen devices
- BD Nano 2nd Gen 320550Becton Dickinson Pen Limited · Needle, hypodermic, single lumen1,892 reports
- BD SafetyGlide 305916Becton, Dickinson And Company · Needle, hypodermic, single lumen1,768 reports
- BD Nano Ultra-Fine 320122Becton Dickinson Pen Limited · Needle, hypodermic, single lumen566 reports
- N/A 305106Becton, Dickinson And Company · Needle, hypodermic, single lumen1 recall465 reports
- N/A 305110Becton, Dickinson And Company · Needle, hypodermic, single lumen418 reports
- BD Safe-Clip 328235Becton, Dickinson and Company Inc · Needle, hypodermic, single lumen268 reports
- BD Ultra-Fine 320109Becton Dickinson Pen Limited · Needle, hypodermic, single lumen208 reports
- BD AutoShield Duo 329515Becton, Dickinson And Company · Needle, hypodermic, single lumen200 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026 · each recall links to the FDA recall notice
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page