Posey 8060Recalls & reported problems
Tidi Products, LLC · BCS W/ SUPPORT SURFACE · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00618125192250), received between Mar 6, 2025 and Apr 2, 2026 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Mechanical Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Problem3
- Material Puncture/Hole1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 2, 2026Material Puncture/Hole
A PATIENT WAS ABLE TO EXIT THE ENCLOSURE BED BY MANIPULATING THE ZIPPERS FROM THE INSIDE OF THE CANOPY. NO INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24768997 ↗MalfunctionMar 6, 2025Mechanical Problem; Mechanical Problem
S/N (B)(6) HAS ZIPPER DAMAGE, ZIPPER SPLITTING RIGHT SIDE PANEL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21536637 ↗MalfunctionMar 6, 2025Mechanical Problem; Mechanical Problem
S/N (B)(6) HAS ZIPPER DAMAGE, ZIPPER SPLIT ON THE LEFT SIDE PANEL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21536609 ↗MalfunctionMar 6, 2025Mechanical Problem; Mechanical Problem
S/N (B)(6) HAS ZIPPER DAMAGE, ZIPPER SPLIT ON LEFT SIDE PANEL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21536601 ↗
FDA clearance and classification
The FDA regulates product code OYS (patient bed with canopy/restraints) under 21 CFR 880.6760 as a Class I device. 21 CFR 880.6760 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
FDA definition of this device type: Enclosed bed canopy system used as passive restraint.
Common questions about the Posey 8060
Has the Posey 8060 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00618125192250), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Posey 8060?
The FDA's MAUDE database lists 4 adverse event reports for this device, received between Mar 6, 2025 and Apr 2, 2026. In those reports, the most common specific device problems are “Mechanical Problem” (3) and “Material Puncture/Hole” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Posey 8060?
None of the reports are classified as deaths, 0 as injuries and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Posey 8060 FDA approved?
Devices of this type (product code OYS) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Tidi Products, LLC.
Who makes the Posey 8060, and is it still sold?
The FDA's device database lists Tidi Products, LLC as the company responsible for it (brand Posey, model 8060). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Patient Bed With Canopy/Restraints devices
- Cubby Beds CUB2Sensory Medical, Inc. · Patient Bed With Canopy/Restraints1 death133 reports
- POSEY A8070TFPosey Products, LLC · Patient Bed With Canopy/Restraints9 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page