DCA Vantage® Analyzer 10282969Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · The DCA Vantage system is a semi-automated, benchtop system. It is designed to quantitatively measure the percent of Hemoglobin A1cin blood and low concentrations of albumin in urine (microalbuminuria), creatinine in urine, and the albumin/creatinine ratio in urine. The DCA Vantage system is intended for professional use in a physician’s office or hospital laboratory. Tests performed usingthe DCA Vantage system are intended for in vitro diagnostic use. · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 20
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 20 adverse event reports that list this exact device (DI 00630414551364), received between Jun 18, 2020 and Sep 28, 2026 — classified as 20 malfunctions.
The most frequently reported specific device problem is “Low Test Results” (9 reports).
1 other recall cover devices cleared under the same FDA submission (K071466); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Low Test Results9
- High Test Results5
- Data Problem1
- Fail-Safe Did Not Operate1
- Leak/Splash1
- Patient Data Problem1
- Smoking1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions18
- Exposure to Body Fluids1
- No Patient Involvement1
Recent adverse event reports
The 20 most recent of 20 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 28, 2026High Test Results
The customer reported that they received a falsely elevated HBA1C result compared to retesting on the another DCA Vantage instrument. The controls were passing. There is no report of injury due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50910828 ↗MalfunctionSep 24, 2026Low Test Results
The customer reported that they received a falsely depressed HBA1C result compared to retesting on a lab instrument. The customer's correct HBA1C results were confirmed by the retest. The controls were passing. There is no report of injury due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50877486 ↗MalfunctionSep 24, 2026High Test Results
The customer reported that they received a falsely elevated HBA1C result compared to retesting on a lab instrument. Patient's HBA1C results were confirmed by retest. There is no report of injury due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50877381 ↗MalfunctionSep 21, 2026High Test Results
The customer reported that they received falsely elevated HBA1C results in 3 patient samples compared to retesting on the same DCA Vantage instrument. The controls were passing. There is no report of injury due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50838982 ↗MalfunctionSep 21, 2026Low Test Results
The customer reported that they received a falsely depressed HBA1C result compared to retesting on a an Atellica DCA instrument and also on another DCA Vantage ((b)(6)). The customer's correct HBA1C results were reported by retest. The controls were passing. There is no report of injury due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50835623 ↗MalfunctionSep 14, 2026Low Test Results
The customer reported that they received a falsely depressed HBA1C result compared to the continuous glucose monitoring (CGM) of the patient. The controls were passing. The patient's HBA1C result was confirmed from the repeat testing. There is no report of injury due to this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50749437 ↗MalfunctionSep 1, 2026Low Test Results
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50537439 ↗MalfunctionAug 14, 2026Low Test Results
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50247872 ↗MalfunctionAug 11, 2026High Test Results
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50206915 ↗MalfunctionJun 16, 2026Low Test Results
THE CUSTOMER REPORTED THAT THEY RECEIVED A FALSELY DEPRESSED HBA1C RESULT COMPARED TO RETESTING ON AN UNKNOWN LAB INSTRUMENT. THE CONTROLS WERE PASSING. THERE IS NO REPORT OF INJURY DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25515998 ↗MalfunctionJun 5, 2026Low Test Results
THE CUSTOMER REPORTED THAT THEY RECEIVED A FALSELY DEPRESSED HBA1C RESULT COMPARED TO RETESTING ON AN UNKNOWN LAB INSTRUMENT. THE CONTROLS WERE PASSING. THERE IS NO REPORT OF INJURY DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25406362 ↗MalfunctionMay 5, 2026High Test Results
THE CUSTOMER REPORTED THAT THEY RECEIVED A FALSELY ELEVATED HBA1C RESULTS COMPARED TO RETESTING PERFORMED ON THE SAME DEVICE. THE CONTROLS WERE PASSING. THERE IS NO REPORT OF INJURY DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25076580 ↗MalfunctionAug 7, 2025Use of Device Problem; Use of Device Problem
THE CUSTOMER REPORTED THAT THE OPERATOR TESTED A SAMPLE UNDER INCORRECT PATIENT ID. THERE IS NO REPORT OF INJURY DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22735371 ↗MalfunctionJul 1, 2025Low Test Results; Low Test Results
THE CUSTOMER REPORTED THAT THEY RECEIVED DISCREPANT MICROALBUMIN, CREATININE AND ALBUMIN-CREATININE RATIO RESULT ON THEIR DCA VANTAGE INSTRUMENT COMPARED TO LAB TEST. THE PATIENT'S RESULTS WERE CONFIRMED FROM THE LAB TEST. THERE IS NO REPORTED INJURY DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22368544 ↗MalfunctionMar 28, 2025Patient Data Problem; Patient Data Problem
THE CUSTOMER REPORTED THAT THE DCA VANTAGE ANALYZER MIXED RESULTS FROM TWO DIFFERENT PATIENT SAMPLES TESTED WITH THE UNIQUE SAMPLE IDENTIFICATION (ID). THE DCA GENERATED RESULTS FROM A SAMPLE PROCESSED ON PATIENT-1, AND COMBINED THE RESULTS FROM A PATIENT-2 SAMPLE USING THE ID OF PATIENT-2. WHILE NO RESULTS WERE DISPLAYED FOR THE PATIENT-1 ID. RESULTS WERE REPORTED TO PHYSICIAN. NO DELAYED OR UNNECESSARY TREATMENT/MEDICAL PROCEDURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21716453 ↗MalfunctionApr 25, 2024Leak/Splash; Leak/Splash
THE CUSTOMER ALLEGED THAT THE OPERATOR'S EYES WERE EXPOSED TO HBA1C REAGENT MIXED WITH PATIENT BLOOD. EXPOSURE OCCURRED WHILE THE OPERATOR WAS RUNNING A HBA1C SAMPLE. THE OPERATOR PULLED THE BUFFER TAB ON THE HBA1C REAGENT AND THE REAGENT MIXED WITH BLOOD SAMPLE SPRAYED THEIR EYES. THE OPERATOR WAS NOT WEARING EYE PROTECTION WHEN THE INDENT OCCURRED. FOLLOWING THE EXPOSURE THE OPERATOR USED THE EYE WASH STATION BUT DID NOT SEEK MEDICAL ATTENTION. CUSTOMER STATED THE OPERATOR IS DOING WELL.
Patient problems: Exposure to Body Fluids
MAUDE report 19184687 ↗MalfunctionJul 25, 2023Low Test Results; Low Test Results
CUSTOMER STATED THAT DISCREPANT LOW MICROALBUMIN AND CREATININE RESULTS WERE OBTAINED WHEN COMPARED TO ANOTHER DCA SYSTEM. THE ISSUE OCCURRED WITH TWO DIFFERENT SAMPLES. THERE IS NO REPORT OF HARM DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17391243 ↗MalfunctionApr 27, 2022Data Problem; Data Problem
THE CUSTOMER REPORTED THAT THEY HAD ONE INCIDENT WHERE THE RESULTS OF ONE PATIENT WERE REPORTED TO A DIFFERENT PATIENT'S ID. THERE HAS BEEN NO REPORT OF INJURY DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14219086 ↗MalfunctionSep 22, 2021Smoking; Smoking
THE CUSTOMER REPORTED THAT THEY SAW SMOKE COMING FROM THEIR DCA VANTAGE ANALYZER. THE ANALYZER WAS IMMEDIATELY UNPLUGGED. THERE WAS A STRONG BURNING SMELL PRESENT AT THE POWER CORD. NO FLAMES WERE SEEN, BUT SMOKE WAS VISIBLE. NO SAMPLE WAS BEING RUN AT THAT TIME. THERE WAS NO REPORT OF INJURY TO ANY PATIENT OR OPERATOR DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12515233 ↗MalfunctionJun 18, 2020Fail-Safe Did Not Operate; Fail-Safe Did Not Operate
INTERNAL TESTING HAS DETERMINED THAT THE DCA VANTAGE EXTERNAL BARCODE SCANNER MODEL DS4308 DOES NOT OPERATE AS INTENDED WHEN USING CODE 39 WITH CHECK DIGIT ENABLED BARCODES. THERE IS A REMOTE POSSIBILITY OF INCORRECT IDENTIFICATION OF PATIENT RESULTS BY THE MEDICAL DEVICE WHEN USING THIS BARCODE SCANNER TO SCAN PATIENT IDS WITH THE INDICATED SYMBOLOGY. THERE HAVE BEEN NO REPORTS OF INJURY DUE TO THIS DEFECT FROM CUSTOMERS.
Patient problems: No Patient Involvement
MAUDE report 10169455 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K071466. One submission often covers many models, so check the product and lot details in each record.
- Z-2747-2020 · Jun 30, 2020 · TerminatedDCA Vantage Handheld Barcode Scanner - Zebra Model - Model # DS4308 - HC0015BZZWW external accessory to DCA Vantage Analyzer US
Other INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.) devices
- Atellica CH uALB_2 11097610Siemens Healthcare Diagnostics Inc. · INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)1 recall3 reports
- ADVIA® Chemistry µALB Microalbumin Reagents 10318197Siemens Healthcare Diagnostics Inc. · INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)1 recall1 report
- One+Step Protein 8194Dfi CO.,Ltd · Indicator Method, Protein Or Albumin (Urinary, Non-Quant.)1 recall0 reports
- CLINITEK Novus® Automated Urine Chemistry Analyzer 10697937Siemens Healthcare Diagnostics Inc. · INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)20 reports
- Tinaquant Albumin Gen2 4469658190Roche Diagnostics GmbH · INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)18 reports
- Tina-quant Albumin Gen.2 08056722190Roche Diagnostics GmbH · INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)11 reports
- CHEMSTRIP MICRAL URINE TEST STRIPS 11544039160Roche Diagnostics GmbH · INDICATOR METHOD, PROTEIN OR ALBUMIN (URINARY, NON-QUANT.)1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page