Attain® Performa™ 429888Recalls & reported problems
Medtronic, Inc. · LEAD 429888 ATTAIN PERFORMA USA · Class 3 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic Attain Performa is a permanent pacemaker electrode lead. Of the 602 reports naming it, many describe the lead needing too much energy to stimulate the heart, infections that led to device removal, and leads moving out of place. The reports include 458 injuries and 7 deaths. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 606
- Deaths reported
- 7
- Injuries reported
- 459
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 606 adverse event reports that list this exact device (DI 00643169002715), received between Aug 5, 2015 and Sep 23, 2026 — classified as 7 deaths, 459 injuries, 140 malfunctions.
The most frequently reported specific device problem is “High Capture Threshold” (169 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem255
- High Capture Threshold169
- Failure to Capture65
- Device Dislodged or Dislocated55
- Capturing Problem50
- High impedance45
- Appropriate Device Problem Term/Code Not Available41
- Impedance Problem24
Patient problems
- Unspecified Infection163
- No Clinical Signs, Symptoms or Conditions147
- No Known Impact Or Consequence To Patient132
- Undesired Nerve Stimulation48
- Muscle Stimulation47
- Device Overstimulation of Tissue25
- Endocarditis15
- Erythema11
Recent adverse event reports
The 25 most recent of 606 reports, in the reporter's own words as published by the FDA.
InjurySep 23, 2026Capturing Problem
It was reported that the Left Ventricular (LV) lead "thresholds "[were]" leading to increased battery drain" from the Cardiac Resynchronization Therapy Defibrillator (CRT-D). The lead was reprogrammed, and the lead and the device remain in use. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50873457 ↗MalfunctionSep 17, 2026High Capture Threshold
It was reported that the Left Ventricular (LV) lead exhibited high capture thresholds. The lead remains in use. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50802038 ↗MalfunctionSep 10, 2026High Capture Threshold
It was reported that that the Left Ventricular (LV) lead exhibited possible high thresholds. The LV lead remains in use. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50705484 ↗MalfunctionSep 8, 2026High impedance
It was reported that the lead exhibited high impedance and Magnetic Resonance Imaging (MRI) Surescan mode could not be programmed for the device as a result. The lead remains in use. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50664170 ↗InjuryAug 25, 2026High impedance
It was reported that the Left Ventricular (LV) lead triggered multiple alerts for undefined high pacing impedance. The lead was reprogrammed and remains in use. No patient complications have been reported as a result of this event.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50432614 ↗InjuryAug 20, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the Cardiac Resynchronization Therapy Defibrillator (CRT-D) system was explanted and replaced due to infection. The patient was experiencing discomfort, redness, and swelling. No further patient complications have been reported as a result of this event.
Patient problems: Discomfort; Erythema; Swelling/ Edema; Unspecified Infection
MAUDE report 50354392 ↗InjuryJun 26, 2026Failure to Capture; High Capture Threshold
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED HIGH THRESHOLDS AND POSSIBLE LOSS OF CAPTURE. THE PATIENT WAS EXPERIENCING SYNCOPE. THE LV LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Syncope/Fainting
MAUDE report 25643931 ↗InjuryMay 20, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO THE PATIENT DEVELOPING ENDOCARDITIS. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. THE PATIENT IS A PARTICIPANT IN A CLINICAL STUDY.
Patient problems: Endocarditis
MAUDE report 25230599 ↗InjuryApr 29, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 25029576 ↗InjuryApr 8, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO CHRONIC SWELLING. THE PATIENT EXPERIENCED INDURATION AND GRANULOMA. THE SYSTEM WAS REPLACED WITH A SINGLE CHAMBER PACEMAKER. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Granuloma; Hypersensitivity/Allergic reaction; Swelling/ Edema; Unspecified Skin and Subcutaneous Tissue Problem
MAUDE report 24817486 ↗InjuryApr 8, 2026Fracture; Difficult to Remove; Material Integrity Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO A POCKET INFECTION. THERE WAS VEGETATION OBSERVED ON THE RIGHT VENTRICULAR (RV) LEAD, AND THE PATIENT HAD A POSITIVE CULTURE FOR KLEBSIELLA PNEUMONIAE. DURING EXPLANT, THE LEFT VENTRICULAR (LV) LEAD FRACTURED DISTALLY BEFORE THE ENTIRE LEAD COULD BE FULLY REMOVED. MOST OF THE LV LEAD WAS REMOVED EXCEPT FOR THE TIP, WHICH REMAINS IN THE PATIENT. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 24817278 ↗InjuryApr 7, 2026Failure to Capture
IT WAS REPORTED THAT DURING A DEVICE CHANGEOUT PROCEDURE, NO CAPTURE WAS IDENTIFIED ON THE LEFT VENTRICULAR (LV) LEAD. THE LV LEAD WAS PROGRAMMED OFF AND REMAINS IMPLANTED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24808817 ↗InjuryMar 24, 2026Extracardiac stimulation; High Capture Threshold
IT WAS REPORTED THAT THE PATIENT PREVIOUSLY EXPERIENCED PHRENIC NERVE STIMULATION, REPROGRAMMING OF THE LEFT VENTRICULAR (LV) LEAD WAS ATTEMPTED BUT NO OTHER VECTORS WERE VIABLE. THERE WAS ALSO POSSIBLE HIGH THRESHOLD ON THE LV LEAD AND THE LEAD WAS REPROGRAMMED. THE LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Inappropriate Device Stimulation of Tissue
MAUDE report 24673813 ↗MalfunctionMar 5, 2026High impedance
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD HAD PACING VECTORS THAT EXHIBITED UNDEFINED HIGH PACING IMPEDANCES. THE LV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24524791 ↗InjuryFeb 26, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED A BACTEREMIA INFECTION ORIGINATING AS AN INFECTED INGROWN TOE NAIL. VEGETATION WAS OBSERVED ON THE DEVICE LEADS. INTRAVENOUS (IV) ANTIBIOTICS WERE ADMINISTERED TO THE PATIENT. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) SYSTEM WAS EXPLANTED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bacteremia; Medical device site infection
MAUDE report 24459090 ↗MalfunctionFeb 19, 2026Appropriate Device Problem Term/Code Not Available; High Capture Threshold
IT WAS REPORTED BY A FAMILY MEMBER, THAT THE PATIENT'S LEFT VENTRICULAR (LV) LEAD WAS "NOT WORKING CORRECTLY". THE LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24393264 ↗InjuryFeb 3, 2026High Capture Threshold; Unstable Capture Threshold
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED HIGH CAPTURE THRESHOLDS AND UNSTABLE CAPTURE THRESHOLDS. THE LEAD WAS CAPPED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24250930 ↗InjuryJan 28, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO EROSION AND INFECTION WITH PURULENT DISCHARGE/PUS. IT WAS NOTED THAT DURING THE REMOVAL OF THE RIGHT ATRIAL (RA) LEAD, THE LEAD SNAPPED OFF IN THE BODY, SO THAT LEAD WAS PARTIALLY REMOVED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Erosion; Purulent Discharge; Unspecified Infection
MAUDE report 24202260 ↗InjuryJan 5, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT PRESENTED TO THE EMERGENCY DEPARTMENT DUE TO SHORTNESS OF BREATH. THE PATIENT WAS ADMITTED FOR FURTHER EVALUATION, AND AN ECHOCARDIOGRAM WAS PERFORMED WHICH SHOWED MOBILE ECHOGENIC DENSITY OF THE RIGHT VENTRICULAR (RV) LEAD CONCERNING FOR THROMBUS OR VEGETATION. IT WAS NOTED THAT BLOOD CULTURES WERE NEGATIVE. A TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE) WAS PERFORMED AND REVIEWED VEGETATION ON THE RIGHT ATRIAL (RA) LEAD CONSISTENT WITH ENDOCARDITIS. THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM REMAINS IN USE. THE PATIENT IS A PARTICIPANT IN A CLINICAL STUDY. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Dyspnea; Endocarditis; Thrombosis/Thrombus; Unspecified Infection
MAUDE report 23967765 ↗MalfunctionDec 30, 2025Failure to Capture; Failure to Capture
IT WAS REPORTED THAT THE PATIENT PRESENTED WITH CHEST PAIN AND SHORTNESS OF BREATH. IT WAS FURTHER REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED LOSS OF CAPTURE ON THE CURRENT ELECTROGRAMS (EGM). THE LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Angina; Dyspnea; No Clinical Signs, Symptoms or Conditions
MAUDE report 23926582 ↗MalfunctionDec 22, 2025Failure to Capture; Failure to Capture
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED INTERMITTENT LOSS OF CAPTURE. ADDITIONALLY, THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED POTENTIAL T-WAVE OVERSENSING (TWOS). THE LV AND RV LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23872465 ↗MalfunctionDec 16, 2025High impedance; High impedance
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD TRIGGERED AN IMPEDANCE WARNING DUE TO UNDEFINED OUT OF RANGE (OOR) HIGH DEFIBRILLATION IMPEDANCE. IT WAS FURTHER REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD TRIGGERED AN IMPEDANCE WARNING FOR UNDEFINED OUT OF RANGE (OOR) HIGH PACING IMPEDANCE. BOTH LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23819011 ↗InjuryDec 10, 2025High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED UNACCEPTABLE CAPTURE THRESHOLDS. THE LEAD WAS CAPPED WITH NO REPLACEMENT. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23766504 ↗InjuryNov 18, 2025High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED HIGH THRESHOLDS. THE LEAD WAS CAPPED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23586725 ↗MalfunctionOct 31, 2025Failure to Capture; Failure to Capture
IT WAS REPORTED THAT THE PATIENT EXPERIENCED A PULSATING FEELING AT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SITE. THE LEFT VENTRICULAR (LV) LEAD EXHIBITED POSSIBLE LOSS OF CAPTURE ON STORED EPISODES. THE CRT-D AND LV LEAD REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23439817 ↗
Other permanent pacemaker Electrode devices
- CapSureFix Novus MRI™ SureScan® 5076-45Medtronic, Inc. · permanent pacemaker Electrode136 deaths16,004 reports
- CapSureFix Novus MRI™ SureScan® 5076-58Medtronic, Inc. · permanent pacemaker Electrode124 deaths8,405 reports
- Capsurefix® Novus 5076-45Medtronic, Inc. · permanent pacemaker Electrode85 deaths7,050 reports
- CapSureFix Novus MRI™ SureScan™ 407652Medtronic, Inc. · permanent pacemaker Electrode69 deaths6,097 reports
- SelectSecure™ MRI SureScan™ 383069Medtronic, Inc. · permanent pacemaker Electrode56 deaths4,850 reports
- Sprint Quattro Secure® 694765Medtronic, Inc. · permanent pacemaker Electrode73 deaths3,852 reports
- Attain Performa™ MRI SureScan™ 429888Medtronic, Inc. · permanent pacemaker Electrode38 deaths3,377 reports
- CapSureFix Novus MRI™ SureScan™ 407645Medtronic, Inc. · permanent pacemaker Electrode38 deaths3,370 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page