NA 3778-60 (UDI 00643169157330)Recalls & reported problems
Medtronic, Inc. · LEAD 3778-60 OCTAD 1X8 BNT STYLT EMAN US · Class 3 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00643169157330), received between Jan 13, 2017 and May 24, 2024 — classified as 3 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
9 other recalls cover devices cleared under the same FDA submission (P840001); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Break2
- Migration or Expulsion of Device2
- Device Operates Differently Than Expected1
- Failure to Deliver Energy1
- High impedance1
- Inappropriate/Inadequate Shock/Stimulation1
- Insufficient Device Problem Information1
Patient problems
- Therapeutic Effects, Unexpected3
- Erosion2
- Ambulation or Postural Difficulties1
- Complaint, Ill-Defined1
- Depression1
- Electric Shock1
- Memory Loss/Impairment1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
InjuryMay 24, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
INFORMATION WAS RECEIVED FROM A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WHO WAS IMPLANTED WITH AN IMPLANTABLE NEUROSTIMULATOR (INS). IT WAS REPORTED THAT THE LEADS WERE ERODING OUT OF THE SKIN. THE DOCTOR CUT AND REMOVED WHAT THEY COULD. THE CAUSE WAS NOT KNOWN AND THE ISSUE WAS RESOLVED. IT WAS NOTED THAT THE IMPLANTABLE NEUROSTIMULATOR HAD PREVIOUSLY BEEN REMOVED.
Patient problems: Erosion
MAUDE report 19392191 ↗InjuryMay 24, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
INFORMATION WAS RECEIVED FROM A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WHO WAS IMPLANTED WITH AN IMPLANTABLE NEUROSTIMULATOR (INS). IT WAS REPORTED THAT THE LEADS WERE ERODING OUT OF THE SKIN. THE DOCTOR CUT AND REMOVED WHAT THEY COULD. THE CAUSE WAS NOT KNOWN AND THE ISSUE WAS RESOLVED. IT WAS NOTED THAT THE IMPLANTABLE NEUROSTIMULATOR HAD PREVIOUSLY BEEN REMOVED.
Patient problems: Erosion
MAUDE report 19392087 ↗MalfunctionJun 15, 2023High impedance; High impedance
ADDITIONAL INFORMATION WAS RECEIVED FROM THE REP. IT WAS REPORTED THAT THEY HAVE BEEN ABLE TO WORK AROUND THE CONTACTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17136810 ↗MalfunctionApr 22, 2019Break; Migration or Expulsion of Device; Break; Migration or Expulsion of Device
REFER TO REGULATORY REPORT # 6000153-2019-00006.
Patient problems: Therapeutic Effects, Unexpected
MAUDE report 8535460 ↗InjuryApr 22, 2019Break; Migration or Expulsion of Device; Inappropriate/Inadequate Shock/Stimulation; Insufficient Device Problem Information; Break; Migration or Expulsion of Device; Inappropriate/Inadequate Shock/Stimulation; Insufficient Device Problem Information
INFORMATION WAS RECEIVED FROM A CONSUMER REGARDING A PATIENT IMPLANTED WITH AN IMPLANTABLE NEUROSTIMULATOR FOR NON-MALIGNANT PAIN AND FAILED BACK SURGERY SYNDROME. IT WAS REPORTED THAT THE LEADS HAD BROKEN AND WERE OUT OF PLACE. THE PATIENT HAD THE LEADS REPLACED. THE PATIENT REPORTED THAT A FEW BROKEN AT FIRST, AND THERE WAS A SHOCK AND IT STOPPED WORKING. A LEAD REVISION WAS DONE, AND THE LEADS WERE REPLACED.
Patient problems: Electric Shock; Therapeutic Effects, Unexpected
MAUDE report 8535440 ↗MalfunctionJan 13, 2017Failure to Deliver Energy; Therapy Delivered to Incorrect Body Area; Device Operates Differently Than Expected; Failure to Deliver Energy; Therapy Delivered to Incorrect Body Area; Device Operates Differently Than Expected
ADDITIONAL INFORMATION WAS RECEIVED FROM THE REP REPORTING THAT THE PATIENT WAS REPROGRAMMED AND THEIR SCS SYSTEM AND THERAPY IS WORKING WELL. THE REP STATED THAT THERE WERE NO ISSUES WITH IMPEDANCE OR COVERAGE.
Patient problems: Ambulation or Postural Difficulties; Complaint, Ill-Defined; Depression; Memory Loss/Impairment; Pain; Therapeutic Effects, Unexpected; Therapeutic Response, Decreased; Undesired Nerve Stimulation
MAUDE report 6251931 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P840001. One submission often covers many models, so check the product and lot details in each record.
- Z-0372-2025 · Sep 18, 2024 · Open, ClassifiedMedtronic Recharger Kits, RS6230, RS7230, and RS5220A, containing components WR9230 and WR9220A Recharger for rechargeable implantable neurostimulators. The Rechargers are used wi
- Z-1691-2024 · Mar 28, 2024 · Open, ClassifiedIntellis AdaptiveStim Product Number 97715, Spinal Cord Stimulator
- Z-0780-2024 · Dec 19, 2023 · Open, ClassifiedModel A710 Intellis Clinician Programmer Application, version 2.0.97
- Z-2159-2021 · Jul 9, 2021 · Open, ClassifiedMedtronic Vectris SureScan MRI, Catalog Numbers: a) 977A260 b) 977A275 c) 977A290
- Z-1926-2016 · May 3, 2016 · TerminatedMedtronic RestoreSensor, Model 37714; and, RestoreSensor SureScan, (MRI), Model 97714, Implantable Neurostimulators. Used to treat chronic, intractable pain of the trunk and/or li
- Z-1147-2015 · Jan 9, 2015 · TerminatedThe Medtronic, Quadripolar ITREL 3 IPG, Model 7425, is a multiprogrammable device designed for use in the Stimulation of the Central Nervous System, Peripheral Nervous System, or m
- Z-1524-2014 · Feb 27, 2014 · TerminatedMedtronic neurostimulators. Restore (37711), RestoreADVANCED (37713), RestoreADVANCED SureScan MRI (97713), RestoreSENSOR (37714), RestoreSENSOR SureScan MRI (97714), PrimeAdvanced
- Z-0278-2014 · Sep 30, 2013 · TerminatedMedtronic RestoreUltra, model 37712, and RestoreSensor, model 37714, Multi-program Rechargeable Neurostimulator for Spinal Cord Stimulation.
- Z-1536-06 · Aug 2, 2006 · TerminatedMedtronic 3777 Lead Kit, 1x8 Low Impedance Lead Kit for Spinal Cord Stimulation (SCS). Manufactured at: Medtronic, Inc., Villalba, Puerto Rico USA. Medtronic, Inc., Minneapolis
Other STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF devices
- Octrode™ 3186St. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF30 deaths32,096 reports
- Intellis™ AdaptiveStim® 97715Medtronic, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF2 deaths23,976 reports
- RestoreSensor™SureScan® 97714Medtronic, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF6 deaths17,903 reports
- Proclaim™ 3660St. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF2 recalls25 deaths13,336 reports
- Intellis™ AdaptiveStim® 97715Medtronic, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF11,487 reports
- Precision Spectra ™ SC-1132Boston Scientific Neuromodulation Corporation · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF53 deaths11,269 reports
- Proclaim™ 5 EliteSt. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF1 recall10 deaths9,661 reports
- Proclaim™ 7 EliteSt. Jude Medical, Inc. · STIMULATOR, SPINAL-CORD, TOTALLY IMPLANTED FOR PAIN RELIEF1 recall12 deaths7,299 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page