Selectsecure™ 383049 (UDI 00643169279186)Recalls & reported problems

Medtronic, Inc. · LEAD 383049 SELECTSECURE US DIR DISP · Class 3 · Implant

Adverse event reports
6
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00643169279186), received between Jan 23, 2019 and Sep 28, 2026 — classified as 4 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Failure to Capture” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Capture3
  • High Capture Threshold3
  • Under-Sensing2
  • Break1
  • Decreased Sensitivity1
  • Low impedance1
  • Over-Sensing1
  • Pacing Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • No Known Impact Or Consequence To Patient2
  • No Consequences Or Impact To Patient1
  • Palpitations1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Failure to Capture

    It was reported that there was no capture on the Right Atrial (RA) lead. The RA lead was explanted. No patient complications have been reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50912209 ↗
  • InjuryAug 13, 2024Low impedance; High Capture Threshold; Low impedance; High Capture Threshold

    IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED A LEAD WARNING FOR LOW IMPEDANCE AND HIGH THRESHOLDS RESULTING IN PREMATURE BATTERY DEPLETION OF THE IMPLANTABLE PULSE GENERATOR (IPG). THE RA LEAD WAS CAPPED AND REPLACED AND THE IPG WAS INITIALLY REPROGRAMMED AND THEN EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19975567 ↗
  • InjuryAug 6, 2020Failure to Capture; Under-Sensing; High Capture Threshold; Failure to Capture; Under-Sensing; High Capture Threshold

    IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED UNDERSENSING, LOSS OF CAPTURE AND HIGH THRESHOLDS. THE LEAD WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10372384 ↗
  • MalfunctionDec 23, 2019Failure to Capture; Failure to Capture

    IT WAS FURTHER REPORTED THAT THE LEAD WAS A HIS LEAD.

    Patient problems: Palpitations

    MAUDE report 9509598 ↗
  • InjuryMay 13, 2019Under-Sensing; Decreased Sensitivity; Under-Sensing; Decreased Sensitivity

    IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED UNDERSENSING AND VERY SMALL P-WAVES. THE RA LEAD WAS CAPPED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8604166 ↗
  • MalfunctionJan 23, 2019Break; Over-Sensing; Pacing Problem; High Capture Threshold; Break; Over-Sensing; Pacing Problem; High Capture Threshold

    IT WAS FURTHER REPORTED THAT THE RA LEAD WAS EXPLANTED AND REPLACED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8271052 ↗

Other permanent pacemaker Electrode devices

All permanent pacemaker Electrode devices →