CD HORIZON® Spinal System NAV2002Recalls & reported problems

Medtronic Sofamor Danek, Inc. · TAP NAV2002 SOLERA AWLTIPTAP 4.5MM · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00643169347540), received between Mar 31, 2020 and Mar 13, 2026 — classified as 1 injury, 5 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

1 other recall cover devices cleared under the same FDA submission (K140454); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 3 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break3
  • Detachment of Device or Device Component1
  • Material Integrity Problem1
  • Mechanical Jam1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • No Known Impact Or Consequence To Patient1
  • Pain1
  • Spinal Cord Injury1
  • Unspecified Nervous System Problem1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 13, 2026Break

    INFORMATION WAS RECEIVED FROM A MANUFACTURER REPRESENTATIVE REGARDING DEVICES USED FOR SPINAL THERAPY. IT WAS REPORTED THAT THE TAPS WERE BROKEN. THERE WAS NO PATIENT INVOLVEMENT REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION RECEIVED THAT THE RATCHET ON T HANDLES WAS LOOSE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24596643 ↗
  • MalfunctionMar 13, 2026Break

    INFORMATION WAS RECEIVED FROM A MANUFACTURER REPRESENTATIVE REGARDING DEVICES USED FOR SPINAL THERAPY. IT WAS REPORTED THAT THE TAPS WERE BROKEN. THERE WAS NO PATIENT INVOLVEMENT REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION RECEIVED THAT THE RATCHET ON T HANDLES WAS LOOSE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24588065 ↗
  • MalfunctionMar 11, 2026Break

    INFORMATION WAS RECEIVED FROM MULTIPLE SOURCES (MANUFACTURER REPRESENTATIVE, USER FACILITY) REGARDING DEVICES USED IN SPINAL THERAPY. IT WAS REPORTED THAT THE DEVICES WERE BROKEN. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24566689 ↗
  • MalfunctionApr 29, 2025Mechanical Jam; Mechanical Jam

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY. IT WAS REPORTED THAT THE TAP STUCK IN PURPLE NAV TRACKER. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21926138 ↗
  • InjuryOct 5, 2023Use of Device Problem; Detachment of Device or Device Component; Use of Device Problem; Detachment of Device or Device Component

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER (HCP) VIA MANUFACTURER REPRESENTATIVE REGARDING SPINAL PRODUCT THAT WILL BE USED IN FUSION SPINAL THERAPY FOR T9-T12 DECOMPRESSION. IT WAS REPORTED THAT THE PATIENT HAS MOTOR AND SENSORY ISSUES IN HIS LEG. NO FURTHER COMPLICATIONS OR SYMPTOMS WERE REPORTED. ADDITIONAL INFORMATION WAS RECEIVED VIA MANUFACTURER REPRESENTATIVE THAT THE BLUE HANDLE BECAME DISENGAGED/MALFUNCTIONED FROM THE AWL TIP TAP CAUSING THE PATIENT A SPINAL CORD INJURY. THE SURGEON BELIEVES THAT THE SCRUB TECH NEVER CORRECTLY ATTACHED THE HANDLE TO THE AWL TIP TAP IN WHICH CAUSED THE INSTRUMENT TO SLIDE OFF THE HANDLE WHEN HE INTRODUCED TO THE SPINE. THERE IS NO ALLEGATION OF THE PURPLE NAV LOCK AS IT WAS SIMPLY ATTACHED TO THE AWL TIP TAP. SURGEON HAD 2 SCREWS IN BEFORE THIS INCIDENT USING THESE SAME INSTRUMENTS WITH NO ISSUE. AFTER THE INCIDENT THE SCRUB TECH THAT IS ALLEGING THE MALFUNCTION WAS GIVEN A BREAK AND WAS REPLACED BY ANOTHER SCRUB TECH FOR THE REMAINDER OF THE CASE. WE CONTINUED TO USE EXACTLY THE SAME INSTRUMENTS FOR 6 MORE SCREWS WITH NO ISSUE. THE REPORTED PATIENTS INJURY IS FROM THE 4.5 AWL TIP TAP WITH THE PURPLE NAV LOCK ATTACHED STRIKING THE

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Pain; Spinal Cord Injury; Unspecified Nervous System Problem

    MAUDE report 17875279 ↗
  • MalfunctionMar 31, 2020Material Integrity Problem; Material Integrity Problem

    MEDTRONIC RECEIVED INFORMATION REGARDING A GUIDANCE SYSTEM AND INSTRUMENT BEING USED INTRA-OPERATIVELY OF A SPINAL PROCEDURE. IT WAS REPORTED THAT THE DRIVER WAS DAMAGED AND IT WAS UNKNOWN HOW IT WAS DAMAGED. THERE WAS NO KNOWN IMPACT ON THE PATIENT OUTCOME. ADDITIONAL INFORMATION WAS RECEIVED STATING THAT A PATIENT WAS NOT PRESENT WHEN THIS ISSUE WAS DISCOVERED SO THERE WAS NO PROCEDURE DELAY. THE DRIVER WAS STILL ABLE TO VERIFY. THE DAMAGE WAS TO THE SHAFT OF THE INSTRUMENT WHERE THE NAVLOCK CONNECTS TO THE INSTRUMENT AS THE DRIVER WOULD NOT PASS THROUGH ANY OF THE NAVLOCKS AT THE FACILITY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9902172 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K140454. One submission often covers many models, so check the product and lot details in each record.

  • Z-2363-2023 · Jul 12, 2023 · Open, Classified
    CD HORIZON Spinal System Solera Awl Tip Tap, REF NAV2006K

Other Orthosis, spondylolisthesis spinal fixation devices

All Orthosis, spondylolisthesis spinal fixation devices →