Kyphon Kurve™ KIT VPK1003Recalls & reported problems
Medtronic Sofamor Danek, Inc. · KIT VPK1003 VERTEBROPLASTY CUR 13 GA · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169414044), received between May 12, 2021 and Jul 21, 2021 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- Device Embedded In Tissue or Plaque1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 21, 2021Break; Break
INFORMATION WAS RECEIVED FROM HEALTHCARE PROFESSIONAL VIA FIELD REPRESENTATIVE REGARDING PATIENT WITH SYMPTOMS OF VERTEBRAL COMPRESSION FRACTURE OF L2 INVOLVED IN KYPHOPLASTY PROCEDURE. LEVELS IMPLANTED: L2. IT WAS REPORTED THAT DURING L2 KYPHOPLASTY, ATTACHED THE CEMENT CARTRIDGE TO THE CURVED NEEDLE AND ATTEMPTED TO INJECT CEMENT. TRIED TO PULL THE NEEDLE BACK A LITTLE AND AT THAT TIME THE PLASTIC HUB OF THE CURVED NEEDLE COMPLETELY SHEARED OFF OF THE METAL NEEDLE. THEN USED A HEMOSTAT CLAMP TO REMOVE THE METAL REMAINS OF THE CURVE NEEDLE FROM THE WORKING CANNULA. THE CEMENT WAS STILL IN GOOD WORKING CONDITION AND NOT TOO THICK. CEMENT WAS MIXED FOR 2 MINUTES AND THE ROOM TEMPERATURE WAS APPROXIMATELY 70 DEGREES F. THIS INCIDENT OCCURRED 6 MINUTES AFTER THE CEMENT HAD BEEN MIXED. ONCE THE REMAINS OF THE CURVED NEEDLE WERE REMOVED, A NEW CURVE KIT (VPK1003) AND CEMENT + MIXER (C01B) WERE OPENED. WITH THE USE OF THE NEW CURVED NEEDLE AND CEMENT THE PROCEDURE WAS COMPLETED WITHOUT INCIDENT. LABELING WAS FOLLOWED THROUGHOUT THE PROCEDURE. NO PATIENT SYMPTOMS OR COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT. ON (B)(6) 2021, RECEIVED ADDITIONAL INFORMATION THAT DELAY WAS APPROXIMATE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12201244 ↗MalfunctionMay 12, 2021Break; Break
IT WAS REPORTED THAT THEY HAD NO PLANS TO REMOVE THE FRAGMENT AS IT WAS NOT CAUSING OR PERCEIVED TO CAUSE ANY CURRENT AND FUTURE PROBLEMS THE DURATION OF THE DELAY WOULD BE THE NORMAL TIME TO REOPEN NEW KIT. APPROXIMATELY 2 MIN. THE PATIENT IS FEELING NORMAL POST OP OUTCOME SYMPTOMS.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 11811147 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page