Medtronic Sofamor Danek, Inc. · DRIVER 6640005 4.75 NON-RETAINING DRIVER · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169492516), received between May 7, 2021 and Feb 12, 2025 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Break” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 2 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break4

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 12, 2025Break; Break

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROFESSIONAL (HCP) VIA A MEDTRONIC REPRESENTATIVE REGARDING A PATIENT UNDERGOING UNKNOWN SPINE SURGERY. IT WAS REPORTED THAT THE TIP OF THE SCREWDRIVER WAS BROKEN WHILE ADJUSTING A SCREW. DOCTOR WAS ABLE TO RETRIEVE THE PIECE OF THE DRIVER. NO HARM TO THE PATIENT OR DELAY TO THE CASE. NO FURTHER COMPLICATIONS REPORTED/ANTICIPATED DUE TO THIS EVENT. ADDITIONAL INFORMATION WAS RECEIVED FROM THE REP THAT PROCEDURE USED IN THIS EVENT WAS TLIF AND PRE OP DIAGNOSIS OF THIS EVENT WAS SPINAL STENOSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21362105 ↗
  • MalfunctionFeb 3, 2025Break; Break

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING L4-1 HARDWARE R EMOVAL FOR AN INDICATION OF PSEUDOARTHROSIS. IT WAS REPORTED THAT THE TIP OF THE INTRUMENTS BROKEN OFF WHILE REMOVING THE PREVIOUS HARDWARE. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21289769 ↗
  • MalfunctionJul 3, 2024Break; Break

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING FRONT/POSTERIOR FUSION AND VERTEBRAL BODY REPLACEMENT. IT WAS REPORTED THAT THE TIP BROKE WHEN ATTEMPTING TO TIGHTEN THE SET SCREW. THERE WERE NO FRAGMENTS OF THE IMPLANTS OR INSTRUMENTS REMAINED IN THE PATIENT'S BODY. PRODUCT WILL BE RETURNED. THERE WERE NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19663949 ↗
  • MalfunctionMay 7, 2021Break; Break

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH CASE OF REDO RIGHT L2-3, LEFT L5-S1 DECOMPRESSION AND TRANSFORAMINAL LUMBAR INTERBODY FUSION AND REMOVAL OF PREVIOUS SCREWS AT L3-4-5, RESTABILIZATION AT L2-3-4-5-1 WITH POSTEROLATERAL FUSION FROM L2-S1 IT WAS REPORTED THAT WE PULLED OUT A 6.5X45 GLOBUS SCREW FROM RIGHT L5. THE SURGEON UPSIZED TO A 7.5X45, AND WENT STRAIGHT TO A VOYAGER 4.75 ATS SCREW. HE WAS STANDING ON THE PATIENTS LEFT SIDE REACHING ACROSS AND DOING THE RIGHT SIDED SCREW. THE ANGLE HE HAD IT IN WAS QUITE LATERAL. THE SCREW BECAME DIFFICULT TO ADVANCE, AND THEN ALL AT ONCE THE DRIVER JUST SPUN INSIDE THE TULIP BECAUSE THE TIP HAD BROKEN OFF IN IT. WE TRIED SEVERAL METHODS TO GET THE BROKEN SCREWDRIVER TIP OUT OF THE TULIP, AND TRIED TO HELICOPTER THE SCREW OUT ALTOGETHER USING A SHORT ROD AND SETCAP. WHAT WE ENDED UP HAVING TO DO WAS USE A METAL CUTTING BURR TO DRILL OUT THE BROKEN OFF PART OF THE SCREWDRIVER, AND THEN WE WERE ABLE TO BACK OUT THE SCREW USING THE HELICOPTER METHOD FROM ABOVE. THIS HAPPENED WITH FIRST THE NAVIGATED DRIVER, AND THEN A SHORT NON RETAINING DRIVER AS WELL BEFORE WE GOT TH

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11789002 ↗

Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices

All ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices →