MiniMed® 530G MMT-751NAH (UDI 00643169503687)Recalls & reported problems

Medtronic Minimed, Inc. · PUMP MMT-751NAH PRDGM 3.0 V3.0 PK EN · Class 3

All models of MiniMed 530G (71)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Medtronic MiniMed 530G insulin pump is part of an artificial pancreas system. Reports describe the display going blank, mechanical trouble, a battery cap that could not be opened, and alarms or insulin squirting out. Hyperglycemia is listed as a patient problem in 447 reports and hypoglycemia in 93. The reports include 5 deaths, 433 injuries and 930 malfunctions. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
1,368
Deaths reported
5
Injuries reported
433
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1,368 adverse event reports that list this exact device (DI 00643169503687), received between May 31, 2017 and Jan 13, 2025 — classified as 5 deaths, 433 injuries, 930 malfunctions.

The most frequently reported specific device problem is “No Display/Image” (220 reports).

2 other recalls cover devices cleared under the same FDA submission (P120010); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • No Display/Image220
  • Patient Device Interaction Problem220
  • Device Difficult to Program or Calibrate206
  • Mechanical Problem204
  • Device Displays Incorrect Message158
  • Obstruction of Flow152
  • Power Problem143
  • Battery Problem128

Patient problems

  • No Consequences Or Impact To Patient828
  • Hyperglycemia447
  • Hypoglycemia93
  • Elevated Ketones/ Diabetic Ketoacidosis22
  • No Known Impact Or Consequence To Patient10
  • Blood Loss9
  • Nausea6
  • Abdominal Pain4

Recent adverse event reports

The 25 most recent of 1,368 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 13, 2025Power Problem; Power Problem

    IT WAS REPORTED TO MEDTRONIC MINIMED THAT THE CUSTOMER EXPERIENCED BATTERY FAILED ALARM. THE CUSTOMER REPORTED NO ADVERSE EVENT. THE EVENT INVOLVED PRODUCT(S) MMT-751NAH. TROUBLESHOOTING WAS PERFORMED. CUSTOMER REPORTED THAT INSULIN PUMP STOPPED WORKING. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. MMT-751NAH WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21135556 ↗
  • MalfunctionApr 19, 2024Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED TO MEDTRONIC MINIMED THAT THE CUSTOMER WAS NOT ABLE TO OPEN BATTERY CAP EVEN AFTER TRYING WITH COIN. THE CUSTOMER REPORTED NO ADVERSE EVENT. THE EVENT INVOLVED PRODUCT MMT-751NAH. TROUBLESHOOTING WAS PERFORMED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WAS RETURNED FOR FAILURE ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19141844 ↗
  • MalfunctionApr 17, 2023Break; Material Integrity Problem; Appropriate Device Problem Term/Code Not Available; Break; Material Integrity Problem; Appropriate Device Problem Term/Code Not Available

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE CUSTOMER STATED THAT THE BATTERY CAP WAS UNABLE TO BE REMOVED AND HAVING AN ISSUE WITH THE PUMP. TROUBLESHOOTING WAS PERFORMED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. IT IS UNKNOWN WHETHER THE CUSTOMER DISCONTINUES USING THE INSULIN PUMP AND THE PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16749158 ↗
  • MalfunctionSep 29, 2020Obstruction of Flow; Battery Problem; Obstruction of Flow; Battery Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD NO DELIVERY ALERT AND CHANGING BATTERY MORE FREQUENTLY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10598915 ↗
  • MalfunctionSep 23, 2020Mechanical Problem; Obstruction of Flow; Battery Problem; Mechanical Problem; Obstruction of Flow; Battery Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD MOTOR ERROR ALARM. CUSTOMER WAS ABLE TO COMPLETE PUMP REWIND. CUSTOMER DID NOT REPORT AN MOTOR POSITION ENCODER ERROR ALARM. THE CUSTOMER STATED THAT THE DRIVE SUPPORT CAP WAS NORMAL. CUSTOMER STATED THAT INSULIN PUMP HAD NO DELIVERY ALARM. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: Hyperglycemia

    MAUDE report 10571650 ↗
  • MalfunctionSep 8, 2020Failure to Cycle; Priming Problem; Failure to Cycle; Priming Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN WAS SQUIRTING OUT DURING MANUAL PRIME AND HAD COMPROMISED FORCE SENSOR SYSTEM ALARM. THE CUSTOMER STATED THAT DRIVE SUPPORT CAP WAS STICKING OUT. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10503621 ↗
  • MalfunctionAug 14, 2020Mechanical Problem; Mechanical Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP RECEIVED MOTOR ERROR. CUSTOMER WAS ABLE TO CLEAR ALARM AND REWIND PROCESS. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10406535 ↗
  • InjuryAug 12, 2020Battery Problem; Battery Problem

    THE CUSTOMER REPORTED VIA PHONE CALL THAT THEY WERE IN HOSPITALIZED DUE TO LOW BLOOD GLUCOSE ON (B)(6) 2020 WITH UNKNOWN BLOOD GLUCOSE LEVEL. THE CUSTOMER REPORTED THAT THE INSULIN PUMP HAD BATTERY DIED EVERY DAY. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: Hypoglycemia

    MAUDE report 10394569 ↗
  • MalfunctionAug 11, 2020Device Difficult to Program or Calibrate; Device Difficult to Program or Calibrate

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE ESCAPE AND ACTIVATION BUTTONS WERE HARDER PRESS, LESS RESPONSIVE AND SOMETIMES HAD TO PRESS TWICE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10389858 ↗
  • MalfunctionAug 7, 2020Failure to Cycle; Failure to Cycle

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD COMPROMISED FORCE SENSOR ALERT. THE DRIVE SUPPORT CAP WAS NORMAL. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10379629 ↗
  • MalfunctionAug 6, 2020Mechanical Problem; Obstruction of Flow; Patient Device Interaction Problem; Mechanical Problem; Obstruction of Flow; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE CUSTOMER WAS NOT ABLE TO READ THE LETTERS ON THE BUTTONS. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10375770 ↗
  • MalfunctionAug 6, 2020Display or Visual Feedback Problem; Obstruction of Flow; Battery Problem; Display or Visual Feedback Problem; Obstruction of Flow; Battery Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD DIFFICULTY TO READ INFORMATION ON THE SCREEN. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP RECEIVED UNEXPLAINED NO DELIVERY ALARM AND BATTERIES NOT LASTING FULL 7 DAYS. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10372659 ↗
  • MalfunctionAug 5, 2020Mechanical Problem; Material Integrity Problem; Priming Problem; Mechanical Problem; Material Integrity Problem; Priming Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD NO DELIVERY ALARMS DURING PRIMING. THE CUSTOMER STATED THEY HAD TO PRIME MORE THAN ONCE AND BATTERY CAP WAS BROKEN. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10366253 ↗
  • MalfunctionAug 4, 2020Use of Device Problem; Priming Problem; Use of Device Problem; Priming Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP SQUIRT INSULIN DURING PRIMING, LOST SETTING DURING BATTERY CHANGE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10361165 ↗
  • MalfunctionAug 3, 2020Device Difficult to Program or Calibrate; Obstruction of Flow; Device Difficult to Program or Calibrate; Obstruction of Flow

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD ACT BUTTON WAS NOT RESPONDING. CUSTOMER STATED THAT THE INSULIN PUMP HAD NO DELIVERY ALERT. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10355027 ↗
  • MalfunctionAug 3, 2020Mechanical Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Patient Device Interaction Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP BUTTONS WERE STICKING AND HAD TO PRESS LONGER FOR RESPONSE. CUSTOMER STATED THAT THE INSULIN PUMP HAD NO DELIVERY ALARM. CUSTOMER STATED THAT THE GEAR REWINDS SLOWER. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10355011 ↗
  • MalfunctionJul 30, 2020Mechanical Problem; Obstruction of Flow; Patient Device Interaction Problem; Mechanical Problem; Obstruction of Flow; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A MOTOR ERROR ALARMS. THE CUSTOMER ALSO REPORTED THAT THE CUSTOMER RECEIVED UNEXPLAINED NO DELIVERY ALARMS AND A CRACK IN THE INSULIN PUMP CASING. CUSTOMER DECLINED TO PROVIDE THEIR BLOOD GLUCOSE READING. TROUBLESHOOTING WAS NOT COMPLETED AS THE CUSTOMER DECLINED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE PUMP WILL NOT BE RETURNED FOR ANALYSIS. NO PRODUCT IS EXPECTED TO RETURN FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10342842 ↗
  • MalfunctionJul 29, 2020Display or Visual Feedback Problem; Patient Device Interaction Problem; Priming Problem; Display or Visual Feedback Problem; Patient Device Interaction Problem; Priming Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP SCREEN HAD RAINBOW EFFECT IN DAYLIGHT MAKING DIFFICULT TO SEE SCREEN. THE CUSTOMER STATED THAT INSULIN PUMP HAD CRACK ON SIDE OF BATTERY COMPARTMENT AROUND THREADING, CRACK ON RESERVOIR COMPARTMENT FROM CLEAR WINDOW TO ESC BUTTON, PRIMING TAKING LONGER TO COMPLETE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10337514 ↗
  • MalfunctionJul 28, 2020Device Alarm System; Mechanical Problem; Device Alarm System; Mechanical Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN WAS NOT DELIVERED AND ALARM WAS ALSO NOT RECEIVED. INSULIN PUMP HAD SLIGHT GRINDING NOISE DURING PRIME PROCESS, REWIND TAKING WAS LONGER. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: Hyperglycemia

    MAUDE report 10331585 ↗
  • MalfunctionJul 28, 2020Device Difficult to Program or Calibrate; Battery Problem; Power Problem; Device Difficult to Program or Calibrate; Battery Problem; Power Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD BUTTONS ARE UNRESPONSIVE AND REJECTED BATTERIES DIMINISHED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10331247 ↗
  • MalfunctionJul 27, 2020No Display/Image; No Display/Image

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A BLANK DISPLAY AFTER RECEIVING A LOW BATTERY ALERT. CUSTOMER STATED THE BATTERY WAS CHANGED, THEN THE SCREEN WENT BLANK. CUSTOMER WAITED FOR 10 MINUTES UNTIL THE BATTERY OUT LIMIT ALARM SOUNDED, INSERTED A NEW BATTERY, AND THE SCREEN STILL DID NOT TURN BACK ON. CUSTOMER¿S BLOOD GLUCOSE WAS 292 MG/DL. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: Hyperglycemia

    MAUDE report 10325022 ↗
  • MalfunctionJul 23, 2020Display or Visual Feedback Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Battery Problem; Power Problem; Patient Device Interaction Problem; Display or Visual Feedback Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Battery Problem; Power Problem; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP SCREEN HAD SCRATCHES OR DAMAGE ON THE DISPLAY, RAINBOW EFFECT MAKING IT HARD TO READ. CUSTOMER REPORTED THAT THE BATTERY LIFE DIMINISHED FROM THE FIRST DAY, SOME BATTERIES LASTING LESS THAN 7 DAYS, INSULIN PUMP REJECTS SOME NEW BATTERIES. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10313788 ↗
  • MalfunctionJul 22, 2020Failure to Cycle; Detachment of Device or Device Component; Failure to Cycle; Detachment of Device or Device Component

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A COMPROMISED FORCE SENSOR SYSTEM ALARM DURING PRIMING. THE DRIVE SUPPORT CAP APPEARS WAS FLUSH. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10312060 ↗
  • InjuryJul 21, 2020Material Integrity Problem; Material Integrity Problem

    CUSTOMER REPORTED VIA PHONE CALL THAT THEY EXPERIENCED HIGH BLOOD GLUCOSE. THE CUSTOMER BLOOD GLUCOSE LEVEL WAS 300 MG/DL TO 400 MG/DL AT THE TIME OF INCIDENT. THE CUSTOMER WAS ASSISTED WITH TROUBLESHOOTING AND DECLINED FOR HIGH BLOOD GLUCOSE. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: Hyperglycemia

    MAUDE report 10300773 ↗
  • MalfunctionJul 20, 2020Mechanical Problem; Mechanical Problem

    INFORMATION RECEIVED BY MED INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A MOTOR ERROR ALARM. DRIVE SUPPORT CAP WAS NORMAL. CUSTOMER STATED INSULIN PUMP WAS EXPOSED TO X RAY. CUSTOMER WAS ABLE TO CLEAR THE ALARM AND ABLE TO REWOUND. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10293900 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P120010. One submission often covers many models, so check the product and lot details in each record.

  • Z-1751-2026 · Feb 13, 2026 · Open, Classified
    MiniMed 530G Insulin Pump (MMT-551, MMT-751)
  • Z-2544-2014 · Mar 13, 2014 · Terminated
    Medtronic MiniMed Paradigm Insulin Infusion Pumps, Paradigm models: MMT-511, MMT-512, MMT-712, MMT-712E, MMT-515, MMT-715, MMT-522, MMT-522K, MMT-722, MMT-722K, MMT-523, MMT-523K

Other Artificial pancreas device system, threshold suspend devices

All Artificial pancreas device system, threshold suspend devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page