MiniMed® 630G MMT-1715KMRecalls & reported problems

Medtronic Minimed, Inc. · PUMP MMT-1715KM 630G V2.8 BK SF MG · Class 3

All models of MiniMed 630G (23)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Quick summary

This MiniMed 630G insulin pump is named in 9,892 adverse event reports, including 50 deaths and 3,328 injuries. The reports mostly describe short battery life, clips or retainer rings that break or come loose, and pump error alarms. Both of its 2 recalls are open: one about reduced battery life after the pump is dropped or bumped, and one about a communication weakness that could allow unauthorized access to the pump.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
9,892
Deaths reported
50
Injuries reported
3,328
Recalls naming it
2

Summary

The FDA's MAUDE database contains 9,892 adverse event reports that list this exact device (DI 00643169873834), received between May 4, 2017 and Jun 25, 2025 — classified as 50 deaths, 3,328 injuries, 6,514 malfunctions.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1,901 reports).

2 FDA recall records name this device's identifier, 2 still open.

8 other recalls cover devices cleared under the same FDA submission (P150001); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Jul 31, 2024Class IOpen, Classified

    Insulin pumps that have been dropped, bumped, or experienced physical impact may have damage to internal electrical components, which may cause reduced pump battery life. Since the defect reduces the battery life overall, it shortens the time between low battery alarms and increases the frequency with which the user must insert a new battery. Further, the defect may also deliver the low battery alarm when there is significantly less time before the battery completely runs out, from the expected up to 10-hour buffer the low alert is supposed to signal, leading to device powering down and stopping insulin delivery unexpectedly. Per the firm, a subset of pumps with the defect showed the low alert alarm was delivered ~2.5 hours before the device shut off, however, patient reports indicate the time could be even shorter. Replacing the battery will not resolve this issue and the short battery life and the truncated low battery alert lead time will continue to occur. Early battery depletion could result in power loss and insulin delivery could be interrupted, resulting in under delivery of insulin potentially leading to hyperglycemia and/or DKA.

    Z-0001-2025 · Root cause: Device Design · Recall details · FDA record ↗

  2. Sep 20, 2022Class IIOpen, Classified

    Medtronic identified a cybersecurity vulnerability in the MiniMed 600 series Insulin Pump Systems associated with the communication protocol that could allow unauthorized access to the pump system. This unauthorized access could be used to deliver too much or too little insulin through delivery of an unintended insulin bolus or because insulin delivery is slowed or stopped, which could lead to hypoglycemia or hyperglycemia. The Remote Bolus feature on insulin pumps should be turned off to prevent the unauthorized access.

    Z-0193-2023 · Root cause: Component change control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1,967
  • Patient Device Interaction Problem1,901
  • No Display/Image1,465
  • No Apparent Adverse Event1,279
  • Material Integrity Problem1,157
  • Break695
  • Device Displays Incorrect Message598
  • Power Problem548

Patient problems

  • No Consequences Or Impact To Patient4,221
  • Hyperglycemia3,321
  • No Clinical Signs, Symptoms or Conditions1,610
  • Hypoglycemia898
  • Elevated Ketones/ Diabetic Ketoacidosis173
  • Nausea77
  • Vomiting73
  • Death35

Recent adverse event reports

The 25 most recent of 9,892 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 25, 2025Battery Problem; Battery Problem

    IT WAS REPORTED TO MEDTRONIC MINIMED THAT THE CUSTOMER EXPERIENCED A LOW BATTERY LIFE OF THE INSULIN PUMP. THE CUSTOMER REPORTED NO ADVERSE EVENT. THE EVENT INVOLVED PRODUCT(S) MMT-1715KM. TROUBLESHOOTING WAS NOT PERFORMED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE CUSTOMER DISCONTINUED USE OF THE INSULIN PUMP. THE PRODUCT WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22325332 ↗
  • InjuryMay 24, 2024Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE CUSTOMER HAD EXPERIENCED HYPOGLYCEMIA AND THE BLOOD GLUCOSE DELIVERY WAS UNDATABLE. THE BLOOD GLUCOSE AT THE TIME OF THE EVENT WAS 76 MG/DL. THE TROUBLESHOOTING WAS PERFORMED. THE CUSTOMER WAS HOSPITALIZED FOR OTHER ISSUES AND THERE WAS NO FURTHER PATIENT COMPLICATIONS WERE REPORTED. THE PRODUCT WILL NOT BE RETURNED FOR ANALYSIS.

    Patient problems: Hypoglycemia

    MAUDE report 19392330 ↗
  • MalfunctionJul 14, 2023Break; Break

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE CUSTOMER REPORTED CLIP DOES NOT STAY ON THE PUMP. TROUBLESHOOTING WAS PERFORMED AND FOUND DAMAGE ON THE GROOVE AT THE BACK OF THE INSULIN PUMP. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. CUSTOMER WAS ADVISED TO DISCONTINUE THE USE OF INSULIN PUMP AND PRODUCT WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17323821 ↗
  • MalfunctionJan 31, 2023Circuit Failure; Mechanical Problem; Circuit Failure; Mechanical Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT CUSTOMER REPORTED PUMP ERROR-43 AND PUMP ERROR-63. NO HARM RECURRING MEDICAL INTERVENTION WAS REPORTED. TROUBLESHOOTING WAS PERFORMED AND CUSTOMER ABLE TO CLEAR THE ALARM AND REWIND TEST. INSULIN PUMP WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16269894 ↗
  • MalfunctionAug 26, 2022Priming Problem; Priming Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD PRIME FILL ANOMALY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE CUSTOMER WAS ASSISTED WITH TROUBLESHOOTING. INSULIN PUMP WILL NOT BE RETURN FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15301518 ↗
  • MalfunctionAug 11, 2022Battery Problem; Battery Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A LOW BATTERY ALERT. CUSTOMER STATED THAT BATTERY DID NOT LAST MORE THAN 1 WEEK. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15207859 ↗
  • MalfunctionAug 5, 2022Break; Break

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE RETAINER RING WAS DAMAGED. THE LOCATION OF DAMAGE WAS THE RESERVOIR RING. THE TYPE OF DAMAGE WAS BROKEN PIECES. THE RESERVOIR WAS ABLE TO LOCK IN PLACE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. TROUBLESHOOTING WAS PERFORMED, THE CUSTOMER WILL DISCONTINUE THE USE OF DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15172927 ↗
  • MalfunctionAug 4, 2022Break; Break

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP RETAINER RING WAS CHIPPED OFF. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15162253 ↗
  • MalfunctionAug 4, 2022Wireless Communication Problem; Wireless Communication Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT CUSTOMER HAD LOW BLOOD GLUCOSE AND WAS HOSPITALIZED FOR CIRRHOSIS. CUSTOMER TOOK OUT BATTERY FROM THE INSULIN PUMP BUT IT DID NOT GET BLOOD GLUCOSE FROM GLUCOMETER. CUSTOMER WAS ASSISTED WITH TROUBLESHOOTING. INSULIN PUMP WAS RETURNED FOR ANALYSIS.

    Patient problems: Hypoglycemia

    MAUDE report 15162224 ↗
  • MalfunctionAug 2, 2022No Apparent Adverse Event; Patient Device Interaction Problem; No Apparent Adverse Event; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS AN ALLEGATION OF HYPERGLYCEMIA AS A RESULT OF THIS EVENT.

    Patient problems: Hyperglycemia

    MAUDE report 15146343 ↗
  • MalfunctionAug 2, 2022Break; Break

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A CRACKED RETAINER RING AND BELT CLIP RAILS. CUSTOMER REPORTED THAT THE DAMAGE OCCURRED DUE TO NORMAL WEAR AND TEAR. CUSTOMER REPORTED THAT THE RESERVOIR WAS ABLE TO LOCK INTO PLACE WHEN INSERTED INTO INSULIN PUMP. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15146262 ↗
  • MalfunctionJul 28, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS AN ALLEGATION OF HYPOGLYCEMIA AS A RESULT OF THIS EVENT.

    Patient problems: Hypoglycemia

    MAUDE report 15120808 ↗
  • MalfunctionJul 26, 2022Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15101702 ↗
  • MalfunctionJul 25, 2022Break; Break

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15093322 ↗
  • MalfunctionJul 25, 2022Break; Break

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15092692 ↗
  • MalfunctionJul 25, 2022Break; Break

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15092184 ↗
  • MalfunctionJul 25, 2022Break; Break

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15090982 ↗
  • MalfunctionJul 22, 2022Break; Patient Device Interaction Problem; Break; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT RETAINER RING WAS MISSING. THE CUSTOMER ALSO STATED THAT THE LIP RING WAS DAMAGED AND THE RESERVOIR SIDE WAS CRACKED. THE CUSTOMER STATED THAT THE RESERVOIR DID LOCK IN PLACE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE CUSTOMER WILL DISCONTINUE THE USE OF DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15083468 ↗
  • MalfunctionJul 22, 2022Break; Patient Device Interaction Problem; Break; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD CRACKED RETAINER RING AND THE RESERVOIR WAS ABLE TO LOCK IN PLACE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. TROUBLESHOOT WAS PERFORMED AND THE CUSTOMER WILL DISCONTINUE USE OF THE DEVICE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15081656 ↗
  • MalfunctionJul 21, 2022Break; Break

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15074284 ↗
  • MalfunctionJul 21, 2022Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT DAMAGE (PHYSICAL OR COSMETIC) OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15071428 ↗
  • MalfunctionJul 20, 2022Break; Battery Problem; No Apparent Adverse Event; Break; Battery Problem; No Apparent Adverse Event

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP ALARMED REPLACE BATTERY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15064744 ↗
  • MalfunctionJul 20, 2022Break; Obstruction of Flow; No Apparent Adverse Event; Patient Device Interaction Problem; Break; Obstruction of Flow; No Apparent Adverse Event; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE RESERVOIR LIP RING OF INSULIN PUMP WAS DAMAGED. THE CUSTOMER STATED THAT THE RESERVOIR WAS ABLE TO LOCK IN PLACE. IT WAS STATED THAT TWO PIECES OF PLASTIC CHIPPED OUT AND THE INSULIN PUMP ALARMED INSULIN FLOW BLOCKED BUT THE ISSUE WAS RESOLVED WITH COMPLETE SET CHANGE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE CUSTOMER WILL DISCONTINUE TO USE THE INSULIN PUMP. THE INSULIN PUMP WAS RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15063394 ↗
  • MalfunctionJul 19, 2022Break; Patient Device Interaction Problem; Break; Patient Device Interaction Problem

    INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE RESERVOIR LIP RING OF INSULIN PUMP AND RESERVOIR COMPARTMENT WAS DAMAGED. THE CUSTOMER STATED THAT THE RESERVOIR WAS ABLE TO LOCK IN PLACE. IT WAS STATED THAT THE RESERVOIR WAS STUCK IN PUMP, CLIP WAS BROKEN OFF AND THE PUMP WAS DROPPED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE CUSTOMER WILL DISCONTINUE TO USE THE INSULIN PUMP. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15049651 ↗
  • MalfunctionJul 18, 2022Communication or Transmission Problem; Loss of Data

    MEDTRONIC RECEIVED INFORMATION THAT PUMP ERROR 15, PUMP ERROR 4 OCCURRED. THERE WAS NO ADVERSE IMPACT OR CONSEQUENCE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15044796 ↗

FDA clearance and classification

Approved through premarket approval (PMA) P150001 on Aug 10, 2016. Submitted by Medtronic Minimed as “Minimed 630g System With Smartguard(Tm)”. The FDA review took 580 days. The FDA has since approved 100 supplements (changes to the device or its labeling), most recently on Jul 21, 2026. FDA record ↗

Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.

FDA definition of this device type: An automated insulin dosing system that temporarily suspends or reduces insulin infusion from an insulin pump based upon specified thresholds of measured glucose levels.

Recalls under the same FDA submission

These recalls involve devices cleared under P150001. One submission often covers many models, so check the product and lot details in each record.

  • Z-1740-2026 · Feb 13, 2026 · Open, Classified
    MiniMed 630G Insulin Pump (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
  • Z-1259-2025 · Jan 31, 2025 · Open, Classified
    MiniMed insulin pump, REF: 630G (MMT-1714, MMT-1715, MMT-1754, MMT-1755)
  • Z-0855-2022 · Jan 27, 2022 · Open, Classified
    MiniMed 630G: MMT-1715, MMT-1754, MMT-1755; MiniMed 670G: MMT-1740, MMT-1741, MMT-1742, MMT-1760, MMT-1761, MMT-1762, MMT-1780, MMT-1781, MMT-1782; MiniMed 770G: MMT-1880, MMT-1881
  • Z-0517-2021 · Apr 30, 2020 · Open, Classified
    MiniMed 630G with SmartGuard, insulin pump, Ref/Model # MMT-1754K, MMT-1714K, MMT-1755K - Product Usage: intended for continuous delivery of basal insulin (at user selectable rate
  • Z-0955-2020 · Nov 21, 2019 · Open, Classified
    Medtronic MiniMed 630G System with SmartGuard, Ref/Model # MMT-1515, MMT-1715, MMT-1714, MMT-1754, and MMT-1755 *US and Canada Version Only
  • Z-0683-2019 · Oct 3, 2018 · Open, Classified
    Medtronic MiniMed 630G 6025805-003_C, Rx Only Medtronic MiniMed 670G 6025805-005_B, Rx Only Medtronic MiniMed 640G (International)
  • Z-2603-2017 · May 8, 2017 · Terminated
    MiniMed 630G Insulin Infusion Pump, Catalog No. MMT-1715, MMT-1755.
  • Z-2602-2017 · May 8, 2017 · Terminated
    MiniMed 620G Insulin Infusion Pump, Catalog No. MMT-1510, MMT-1710, MMT-1550, MMT-1750.

Common questions about the MiniMed® 630G MMT-1715KM

Has the MiniMed® 630G MMT-1715KM been recalled?

Yes. 2 FDA recall records name this device's identifier: 2 still open. The most recent, Z-0001-2025 (Class I), began on Jul 31, 2024: Insulin pumps that have been dropped, bumped, or experienced physical impact may have damage to internal electrical components, which may cause reduced pump battery life. Since the defect reduces the battery life… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the MiniMed® 630G MMT-1715KM?

The FDA's MAUDE database lists 9,892 adverse event reports for this device, received between May 4, 2017 and Jun 25, 2025. In those reports, the most common specific device problems are “Patient Device Interaction Problem” (1,901), “No Display/Image” (1,465) and “Material Integrity Problem” (1,157); the most common patient problems are “Hyperglycemia” (3,321), “Hypoglycemia” (898) and “Elevated Ketones/ Diabetic Ketoacidosis” (173). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the MiniMed® 630G MMT-1715KM?

50 reports are classified as deaths, 3,328 as injuries and 6,514 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the MiniMed® 630G MMT-1715KM FDA approved?

It was approved through premarket approval (PMA) P150001 on Aug 10, 2016.

Is the MiniMed® 630G MMT-1715KM MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Unsafe: it should not be taken into an MRI scanner room.

Who makes the MiniMed® 630G MMT-1715KM, and is it still sold?

The FDA's device database lists Medtronic Minimed, Inc. as the company responsible for it (brand MiniMed® 630G, model MMT-1715KM). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Artificial pancreas device system, threshold suspend devices

All Artificial pancreas device system, threshold suspend devices →