MiniMed® 530G MMT-751LNAH (UDI 00643169507753)Recalls & reported problems
Medtronic Minimed, Inc. · PUMP MMT-751LNAH PRDGM V3.0 PK EN PR LN · Class 3
All models of MiniMed 530G (71)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic MiniMed 530G insulin pump has 693 adverse event reports, with no deaths and 276 injuries. Many describe mechanical problems, incorrect messages, unexpected no-delivery alarms and buttons that are hard to press; patients also reported high or low blood sugar. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 693
- Deaths reported
- 0
- Injuries reported
- 276
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 693 adverse event reports that list this exact device (DI 00643169507753), received between May 23, 2017 and Sep 29, 2020 — classified as 276 injuries, 417 malfunctions.
The most frequently reported specific device problem is “Mechanical Problem” (115 reports).
2 other recalls cover devices cleared under the same FDA submission (P120010); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Mechanical Problem115
- Device Displays Incorrect Message108
- Device Difficult to Program or Calibrate89
- Patient Device Interaction Problem87
- Obstruction of Flow69
- Adverse Event Without Identified Device or Use Problem68
- Power Problem59
- No Display/Image54
Patient problems
- No Consequences Or Impact To Patient384
- Hyperglycemia259
- Hypoglycemia60
- Elevated Ketones/ Diabetic Ketoacidosis13
- Nausea4
- Vomiting4
- Blood Loss2
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 25 most recent of 693 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 29, 2020Patient Device Interaction Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC STATED THAT THE RETAINER RING WAS DAMAGED. CUSTOMER STATED THAT THEY WERE ABLE TO LOCK IN PLACE THE RESERVOIR WHEN INSERTED IN INSULIN PUMP. NO HARM WAS REQUIRED DURING MEDICAL INTERVENTION. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10598067 ↗MalfunctionAug 7, 2020Failure to Cycle; Failure to Cycle
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP RECEIVED COMPROMISED FORCED SENSOR ALARM DURING REWINDING AND PRIMING. CUSTOMER REPORTED THE DRIVE SUPPORT CAP WAS NORMAL. THE FORCE SENSOR WAS NO LONGER DETECTING RESERVOIR DURING SEATING. NO HARM REQUIRING MEDICAL INTERVENTION WAS NOTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10377810 ↗MalfunctionAug 6, 2020Failure to Cycle; Detachment of Device or Device Component; Failure to Cycle; Detachment of Device or Device Component
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A COMPROMISED FORCE SENSOR SYSTEM ALARM. THE DRIVE SUPPORT CAP WAS NOT NORMAL. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10371789 ↗MalfunctionAug 4, 2020Mechanical Problem; Obstruction of Flow; Battery Problem; Mechanical Problem; Obstruction of Flow; Battery Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD MOTOR ERROR. THE CUSTOMER ALSO STATED THAT, THERE WERE CRACK ON THE CASE AND BATTERY LASTING LESS THAN 7 DAYS AND ALSO HAD UNEXPLAINED NO DELIVERY ALARMS. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10361522 ↗MalfunctionJul 30, 2020Device Difficult to Program or Calibrate; Device Difficult to Program or Calibrate
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD KEYPAD ANOMALY. THE CUSTOMER WAS REPORTED THAT ALL BUTTONS WERE DIFFICULT TO PRESS. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10343238 ↗MalfunctionJul 30, 2020Mechanical Problem; Mechanical Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD MOTOR ERROR ALARM OCCURRED. CUSTOMER REPORTED THAT THE DRIVE SUPPORT CAP WAS CORRECT. CUSTOMER WAS ABLE TO CLEAR THE ALARM. CUSTOMER WAS UNABLE TO REWIND THE INSULIN PUMP. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10342935 ↗MalfunctionJul 24, 2020Computer Software Problem; Display or Visual Feedback Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Date/Time-Related Software Problem; Battery Problem; Computer Software Problem; Display or Visual Feedback Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Date/Time-Related Software Problem; Battery Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE ESCAPE BUTTON HAD TO PRESS MULTIPLE TIMES TO GET IT WORK. CUSTOMER REPORTED THAT THE INSULIN PUMP LOOSENED THE TIME. CUSTOMER MENTIONED THAT THE INSULIN PUMP TOOK LONGER TO REWIND AND INSULIN SQUIRTED WHEN PRIMING. CUSTOMER STATED THAT THE INSULIN PUMP GAVE RANDOM NO DELIVERY AND AN ERROR CODE ALARMS, INSULIN PUMP LOSE ALL SETTINGS EVERY TIME ON BATTERY CHANGE. CUSTOMER DECLINED TO TROUBLESHOOTING WITH 24 HOURS HELPLINE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10318521 ↗MalfunctionJul 21, 2020Mechanical Problem; Power Problem; Patient Device Interaction Problem; Mechanical Problem; Power Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP MOTOR ERROR. THE CUSTOMER ALSO STATED THAT, THE SCREEN IS SCUFFED, BATTERY NOTCH HAS PLASTIC MISSING, BAD BATTERY ALERT, RANDOM NO DELIVERY ALARMS, INSULIN PUMP LOSSES TIME AND DATE IF BATTERY IS OUT TOO LONG. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10300692 ↗MalfunctionJul 20, 2020Mechanical Problem; Obstruction of Flow; Battery Problem; Material Integrity Problem; Mechanical Problem; Obstruction of Flow; Battery Problem; Material Integrity Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP RECEIVED MOTOR ERROR ALARM. CUSTOMER REPORTED THAT THE INSULIN PUMP RECEIVED NO DELIVERY ALARMS AND SLOWER DURING REWIND PROCESS. CUSTOMER STATED THAT BATTERY CAP WAS STRIPPED AS WELL AS INSULIN PUMP HAD POOR BATTERY LIFE. CUSTOMER DECLINED TO TROUBLESHOOTING WITH 24 HOURS HELPLINE. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10294866 ↗MalfunctionJul 16, 2020Device Difficult to Program or Calibrate; Obstruction of Flow; Battery Problem; Power Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Battery Problem; Power Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP BUTTON WAS STICK AND SHUT OFF BECOME NO RESPONSIVE. CUSTOMER REPORTED THAT THE BATTERY CAP WAS MISSING AND NO DELIVERY ALARM AND REJECT NEW BATTERY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10281812 ↗MalfunctionJul 15, 2020Mechanical Problem; Device Difficult to Program or Calibrate; Battery Problem; Material Integrity Problem; Patient Device Interaction Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Battery Problem; Material Integrity Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP BUTTON HAD TO BE PRESSED MORE THAN ONCE. CUSTOMER REPORTED THAT THE SLOWER AND GRINDS TO REWIND, BATTERY CAP HA CRACK. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10274975 ↗InjuryJul 14, 2020Mechanical Problem; Priming Problem; Mechanical Problem; Priming Problem
THE CUSTOMER REPORTED VIA PHONE CALL THAT THEY WERE EXPERIENCING LOW BLOOD GLUCOSE LEVEL. BLOOD GLUCOSE LEVEL AT THE TIME OF THE INCIDENT WAS 39 MG/DL, 49 MG/DL. CUSTOMER WAS TREATED WITH COKE. CUSTOMER STATED INSULIN PUMP HAD PRIMING ISSUE AND STUCK IN REWIND. CUSTOMER DECLINED TROUBLESHOOTING FOR LOW BLOOD GLUCOSE LEVEL. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: Hypoglycemia
MAUDE report 10269284 ↗MalfunctionJul 13, 2020Device Difficult to Program or Calibrate; Obstruction of Flow; Battery Problem; Patient Device Interaction Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Battery Problem; Patient Device Interaction Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP BUTTONS WERE LESS RESPONSIVE AND WAS STICKING. CUSTOMER STATED INSULIN PUMP HAD NO DELIVERY ALERT, CRACK AT BACK, CHANGING BATTERY MORE FREQUENTLY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10262580 ↗MalfunctionJul 6, 2020No Display/Image; No Display/Image
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A BLANK DISPLAY. DISPLAY DID NOT RETURNED AFTER INSULIN PUMP RESTART. TROUBLESHOOTING WAS PERFORMED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10231636 ↗MalfunctionJul 6, 2020Computer Software Problem; No Display/Image; Device Difficult to Program or Calibrate; Computer Software Problem; No Display/Image; Device Difficult to Program or Calibrate
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP SHUT DOWN AT NIGHT AND BUTTONS ALL JUST STOPPED WORKING. THE CUSTOMER HAD ISSUE WITH INSULIN DELIVERY. THE CUSTOMER STATED THAT THE BUTTONS WERE INTERMITTENTLY WORKING. THE TIME WAS ADVANCING. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10231444 ↗MalfunctionJun 25, 2020Failure to Cycle; Mechanical Problem; Failure to Cycle; Mechanical Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD A COMPROMISED FORCE SENSOR SYSTEM ALARM. THE CUSTOMER STATED THAT THE INSULIN PUMP WAS SQUIRTING INSULIN OUT DURING MANUAL PRIME PROCESS. THE INSULIN PUMP WAS NOT BUMPED OR DROPPED PRIOR TO THE ALARM AND THEY ARE UNABLE TO DESCRIBE DRIVE SUPPORT CAP. CUSTOMER STATED THEY WERE STUCK IN REWIND COMPLETE PROCESS. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10194322 ↗MalfunctionJun 22, 2020Mechanical Problem; Power Problem; Mechanical Problem; Power Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD MOTOR ERROR ALARM AND REJECTED NEW BATTERY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE DEVICE WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10182593 ↗MalfunctionJun 17, 2020Mechanical Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Power Problem; Priming Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Obstruction of Flow; Power Problem; Priming Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE BUTTONS ON THE INSULIN PUMP WERE HARD TO PUSH. CUSTOMER STATED THAT THE INSULIN PUMP HAD NO DELIVERY ALARMS. CUSTOMER STATED THAT THE INSULIN PUMP REJECTED NEW BATTERIES. INSULIN PUMP WAS MAKING CRACKING NOISE WHEN REWINDING. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10161711 ↗MalfunctionJun 9, 2020Priming Problem; Priming Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP SQUIRTING INSULIN PRIME. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10131666 ↗MalfunctionJun 8, 2020Obstruction of Flow; Material Integrity Problem; Patient Device Interaction Problem; Priming Problem; Obstruction of Flow; Material Integrity Problem; Patient Device Interaction Problem; Priming Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN SQUIRTED WHEN PRIMING. CUSTOMER STATED INSULIN PUMP HAD DISCOLORATION ON THE SCREEN AND CRACK WHEN REMOVING THE RESERVOIR. CUSTOMER ALSO STATED INSULIN PUMP HAD NO DELIVERY ALARM AND BATTERY CAP WAS DAMAGED. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10131597 ↗MalfunctionJun 6, 2020Mechanical Problem; Mechanical Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP A HAD MOTOR ERROR ALARM AND MOTION SENSOR TEST FAILURE ALARMS. THE CUSTOMER STATED THEY WERE ABLE TO CLEAR THE ALARM AND WERE NOT ABLE TO COMPLETE THE REWIND PROCESS. CUSTOMER REPORTED THE DRIVE SUPPORT CAP WAS NORMAL. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10126320 ↗MalfunctionMay 15, 2020No Display/Image; Battery Problem; No Display/Image; Battery Problem
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT INSULIN PUMP HAD BLANK DISPLAY AND LOW BATTERY. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE CUSTOMER WAS ASSISTED WITH TROUBLESHOOTING. THE DEVICE WILL BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10060476 ↗InjuryMay 12, 2020Obstruction of Flow; Detachment of Device or Device Component; No Apparent Adverse Event; Obstruction of Flow; Detachment of Device or Device Component; No Apparent Adverse Event
IT WAS REPORTED THAT THE CUSTOMER EXPERIENCED HIGH BLOOD GLUCOSE. BLOOD GLUCOSE LEVEL WAS 500 MG/DL. THE CUSTOMER REPORTED EXCESSIVE NO DELIVERY ALARMS. CUSTOMER REPORTED THAT DRIVE SUPPORT CAP WAS STICKING OUT. CUSTOMER REPORTED THAT INSULIN PUMP WAS NOT DROPPED OR EXPOSED TO MAGNET FIELD. CUSTOMER TREATED WITH INSULIN PEN. THE PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: Hyperglycemia
MAUDE report 10048013 ↗MalfunctionMay 12, 2020Mechanical Problem; Obstruction of Flow; Mechanical Problem; Obstruction of Flow
INFORMATION RECEIVED BY MEDTRONIC INDICATED THAT THE INSULIN PUMP HAD RANDOM MOTOR ALARM, RANDOM NO DELIVERY ALARM AND FORCED HER TO REWIND. NO HARM REQUIRING MEDICAL INTERVENTION WAS REPORTED. THE INSULIN PUMP WILL NOT BE RETURNED FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10046381 ↗MalfunctionMay 12, 2020Display or Visual Feedback Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Patient Device Interaction Problem; Display or Visual Feedback Problem; Mechanical Problem; Device Difficult to Program or Calibrate; Patient Device Interaction Problem
THE CUSTOMER REPORTED REWINDING AND KEYPAD ANOMALY VIA PHONE CALL. CUSTOMER BLOOD GLUCOSE READING WAS UNKNOWN. TROUBLESHOOTING WAS NOT PERFORMED. INSULIN PUMP WILL NOT BE RETURNING FOR ANALYSIS.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10045924 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P120010. One submission often covers many models, so check the product and lot details in each record.
- Z-1751-2026 · Feb 13, 2026 · Open, ClassifiedMiniMed 530G Insulin Pump (MMT-551, MMT-751)
- Z-2544-2014 · Mar 13, 2014 · TerminatedMedtronic MiniMed Paradigm Insulin Infusion Pumps, Paradigm models: MMT-511, MMT-512, MMT-712, MMT-712E, MMT-515, MMT-715, MMT-522, MMT-522K, MMT-722, MMT-722K, MMT-523, MMT-523K
Other Artificial pancreas device system, threshold suspend devices
- t:slim X2 Insulin Pump with Basal-IQ 1000886Tandem Diabetes Care, Inc. · Automated Insulin Dosing , Threshold Suspend1 recall17 deaths108,656 reports
- MiniMed® 630G MMT-1715KMedtronic Minimed, Inc. · Artificial pancreas device system, threshold suspend4 recalls98 deaths35,170 reports
- t:slim X2 Insulin Pump with Basal-IQ 1000912Tandem Diabetes Care, Inc. · Automated Insulin Dosing , Threshold Suspend1 recall2 deaths30,219 reports
- t:slim X2 Insulin Pump with Basal-IQ 1000898Tandem Diabetes Care, Inc. · Automated Insulin Dosing , Threshold Suspend1 recall6 deaths16,106 reports
- MiniMed® 630G MMT-1715KMMedtronic Minimed, Inc. · Artificial pancreas device system, threshold suspend2 recalls50 deaths9,892 reports
- MiniMed® 630G MMT-1715KMedtronic Minimed, Inc. · Automated insulin dosing , threshold suspend4 recalls36 deaths7,947 reports
- MiniMed® 530G MMT-751NASMedtronic Minimed, Inc. · Artificial pancreas device system, threshold suspend36 deaths7,479 reports
- MiniMed®630G MMT-1715KMedtronic Minimed, Inc. · Artificial pancreas device system, threshold suspend2 recalls17 deaths6,645 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page