INFINITY™ Occipitocervical Upper Thoracic System G3602537Recalls & reported problems
Medtronic Sofamor Danek, Inc. · CROSSLINK G3602537 ROD TO ROD L · Class 2 · Implant
All models of INFINITY Occipitocervical Upper Thoracic System (35)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169549487), received between Mar 9, 2021 and Mar 9, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Deformation” (1 report).
5 other recalls cover devices cleared under the same FDA submission (K163375); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Deformation1
- Scratched Material1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 9, 2021Material Deformation; Scratched Material; Material Deformation; Scratched Material
INFORMATION WAS RECEIVED FROM HEALTHCARE PROFESSIONAL VIA FIELD REPRESENTATIVE REGARDING PATIENT WITH SYMPTOMS OF DISLOCATION FRACTURE AT C7 INVOLVED IN C2-T3 FIXATION WAS PERFORMED AND C7 WAS SKIPPED FOR C7 DISLOCATION FRACTURE. LEVELS IMPLANTED- C2-T3. IT WAS REPORTED THAT AT INTRA-OP, THE OUTER SET SCREW STRIPPED WHEN THE CROSSLINK WAS FINALLY TIGHTENED. IMPLANT DID NOT BREAK. PRODUCT WAS USED CORRECTLY ACCORDING TO THE DIRECTIONS GIVEN IN THE IFU/LABELING. PRODUCT WAS NOT IMPLANTED IN THE PATIENT. THERE WAS NO DELAY IN OVERALL PROCEDURE TIME. PATIENT WAS NOT HOSPITALIZED PROLONG. THERE WERE NO PATIENT SYMPTOMS/COMPLICATIONS REPORTED AS A RESULT OF THE EVENT. NO HEALTH DAMAGE IN THE PATIENT WAS REPORTED. ON 2021-MAR-04, RECEIVED ADDITIONAL INFORMATION THAT SET SCREW HOLE SCREW THREADS OF BOTH ARMS WERE SCRATCHED, UPPER ARM SET SCREW TIP SLIGHTLY SCRATCHED, AND HEX HOLE WAS STRIPPED. THE CENTER OF SCREW HEX HOLE WAS ALSO SLIGHTLY STRIPPED. BOTH THE DRIVERS WERE STRIPPED AT TIP. ONE OF THE DRIVER COULD NOT MATE WITH THE SAMPLE INFINITY SET SCREW M6. ANOTHER DRIVER COULD MATE WITH THE RETURNED IF ROD CROSSLINK L. IF TORQUE LIMITING HANDLE HAD NO OBVIOUS DEFECT IN APPEARANCE. THE HA
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11442401 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K163375. One submission often covers many models, so check the product and lot details in each record.
- Z-1412-2023 · Feb 16, 2023 · Open, ClassifiedINFINITY Occipitocervical Upper Thoracic System, MULTI AXIAL SCREW, Size: 4.0mm x 26mm, REF 3604026; for immobilization and stabilization of spinal segment as an adjunct to fusion
- Z-1410-2023 · Feb 16, 2023 · Open, ClassifiedINFINITY Occipitocervical Upper Thoracic System, MULTI AXIAL SCREW, Size: 4.0mm x 32mm, REF 3604532; for immobilization and stabilization of spinal segment as an adjunct to fusion
- Z-1413-2023 · Feb 16, 2023 · Open, ClassifiedINFINITY Occipitocervical Upper Thoracic System, MULTI AXIAL SCREW, Size: 4.0mm x 34mm, REF 3604034; for immobilization and stabilization of spinal segment as an adjunct to fusion
- Z-1409-2023 · Feb 16, 2023 · Open, ClassifiedINFINITY Occipitocervical Upper Thoracic System, MULTI AXIAL SCREW, Size: 4.0mm x 24mm, REF 3604024; for immobilization and stabilization of spinal segment as an adjunct to fusion
- Z-1411-2023 · Feb 16, 2023 · Open, ClassifiedINFINITY Occipitocervical Upper Thoracic System, PARTIALLY THREADED MULTI AXIAL SCREW, Size: 4.0mm x 22mm, REF 360PT4022; for immobilization and stabilization of spinal segment as
Other Orthosis, cervical pedicle screw spinal fixation devices
- INFINITY™ Occipitocervical Upper Thoracic System 3604026Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation2 recalls1 report
- CONNECTOR 79-2003Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 360PT4022Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- CONNECTOR 79-2002Orthofix US LLC · Posterior cervical screw system1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604532Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- INFINITY™ Occipitocervical Upper Thoracic System 3604024Medtronic Sofamor Danek, Inc. · Orthosis, cervical pedicle screw spinal fixation1 recall0 reports
- OASYS 48551000Stryker Corporation · Orthosis, cervical pedicle screw spinal fixation45 reports
- YUKON OCT Spinal System 7601-05030VB Spine LLC · Orthosis, cervical pedicle screw spinal fixation15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page