MOSAIC® 305C225 (UDI 00643169594708)Recalls & reported problems
Medtronic, Inc. · VLV 305C225 MOSAIC AOR CII US PEEK · Class 3 · Implant
- Adverse event reports
- 23
- Deaths reported
- 1
- Injuries reported
- 17
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 23 adverse event reports that list this exact device (DI 00643169594708), received between Dec 5, 2017 and Sep 11, 2026 — classified as 1 death, 17 injuries, 5 malfunctions.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (7 reports).
3 other recalls cover devices cleared under the same FDA submission (P990064); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information7
- Device Stenosis6
- Gradient Increase4
- Intravalvular regurgitation4
- Patient Device Interaction Problem4
- Adverse Event Without Identified Device or Use Problem1
- Calcified1
- Perivalvular Leak1
Patient problems
- Aortic Valve Stenosis8
- Insufficient Information7
- Aortic Valve Insufficiency/ Regurgitation5
- Non specific EKG/ECG Changes2
- Bacterial Infection1
- Bradycardia1
- Calcium Deposits/Calcification1
- Cardiac Tamponade1
Recent adverse event reports
The 23 most recent of 23 reports, in the reporter's own words as published by the FDA.
InjurySep 11, 2026Intravalvular regurgitation
It was reported that 6 years post implant of this 25mm aortic bioprosthetic valve, the patient is being evaluated for a transcatheter valve-in-valve replacement. The reason for evaluation was reported as severe aortic central regurgitation. Subsequently on the same day the patient successfully had a 26mm aortic transcatheter valve-in-valve replacement. No additional adverse patient effects were reported.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 50734088 ↗InjuryMay 28, 2026Patient Device Interaction Problem
IT WAS REPORTED THAT POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, THE PATIENT PRESENTED TO THE EMERGENCY DEPARTMENT WITH FEVER, HYPOXIA, ENCEPHALOPATHY, HYPOTENSION AND WAS ADMITTED TO THE MEDICAL INTENSIVE CARE UNIT. A COMPUTED TOMOGRAPHY ANGIOGRAPHY PERFORMED SHOWED LOCULATED LEFT EMPYEMA AND LIKELY ADJACENT PNEUMONIA. BLOOD CULTURES AND URINE CULTURES PERFORMED, WERE POSITIVE AND A TRANSESOPHAGEAL ECHOCARDIOGRAPHY PERFORMED REPORTED NEGATIVE FOR VEGETATION. A LEFT THORACOSTOMY TUBE FOR EMPYEMA DRAINAGE WAS PERFORMED AND EMPYEMA FLUID CULTURES WERE POSITIVE. IT WAS REPORTED THAT ANTIBIOTIC AND VASOPRESSOR MEDICATIONS WERE GIVEN. SUBSEQUENTLY, THE PATIENT SUCCESSFULLY HAD AN AORTIC VALVE-IN-VALVE REPLACEMENT WITH A TRANSCATHETER VALVE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Bacterial Infection; Encephalopathy; Hypoxia
MAUDE report 25314410 ↗InjuryMay 27, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT 4 YEARS AND 4 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, IT WAS EXPLANTED AND REPLACED WITH AN UNKNOWN DEVICE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 25300291 ↗InjuryMay 25, 2026Patient Device Interaction Problem
IT WAS REPORTED THAT 1 YEAR AND 8 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, A BI-VENTRICULAR DEFIBRILLATOR WAS IM PLANTED. THE REASON FOR THE BI-VENTRICULAR DEFIBRILLATOR WAS REPORTED AS LOW EJECTION FRACTION (EF). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Non specific EKG/ECG Changes
MAUDE report 25269322 ↗MalfunctionMay 19, 2026Thickening of Material
IT WAS REPORTED THAT 7 YEARS AND 1 MONTH POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, MILDLY THICKENED LEAFLETS OF THE VALVE WERE REPORTED. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 25214156 ↗MalfunctionApr 21, 2026Device Stenosis
IT WAS REPORTED THAT 5 YEARS AND 7 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS VALVE STENOSIS. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis
MAUDE report 24938800 ↗InjuryMar 13, 2026Intravalvular regurgitation
MEDTRONIC RECEIVED INFORMATION THAT 4 YEARS AND 8 MONTHS POST IMPLANT OF THIS AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS AORTIC INSUFFICIENCY. AN INTERVENTION IS REQUIRED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 24590545 ↗InjuryJan 23, 2026Insufficient Device Problem Information; Device Stenosis; Intravalvular regurgitation
IT WAS REPORTED THAT 7 YEARS AND 5 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, A TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Aortic Valve Stenosis; Insufficient Information
MAUDE report 24161627 ↗InjurySep 15, 2025Device Stenosis; Device Stenosis
MEDTRONIC RECEIVED INFORMATION 6 YEARS AND 9 MONTHS POST IMPLANT OF THIS AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS AORTIC STENOSIS. IT WAS REPORTED THAT THE PATIENT DEVELOPED SYMPTOMS OF SHORTNESS OF BREATH. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis; Dyspnea
MAUDE report 23051507 ↗InjuryJul 10, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT 3 YEARS AND 2 MONTHS POST IMPLANT OF THIS MOSAIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Heart Block
MAUDE report 22468674 ↗InjuryJul 9, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT A PATIENT UNDERWENT AN AORTIC VALVE REPLACEMENT PROCEDURE, WHICH INVOLVED THE REMOVAL OF AN EXISTING AORTIC VALVE AND THE IMPLANTATION OF A NEW AORTIC VALVE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Insufficient Information
MAUDE report 22465360 ↗MalfunctionMay 8, 2025Gradient Increase; Device Stenosis; Gradient Increase; Device Stenosis
MEDTRONIC RECEIVED INFORMATION THAT 6 YEARS AND 7 MONTHS POST IMPLANT OF THIS AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS STENOSIS AND INCREASED GRADIENT. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis
MAUDE report 21985453 ↗InjuryMar 25, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
ADDITIONAL INFORMATION WAS RECEIVED THAT THE PATIENT DID NOT HAVE ANY PRE-EXISTING ARRHYTHMIAS PRIOR TO THE HEART VALVE IMPLANT AND THE PHYSICIAN BELIEVES THE HEART VALVE OR IMPLANT PROCEDURE CAUSED OR CONTRIBUTED TO THE EVENT. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Bradycardia; Non specific EKG/ECG Changes
MAUDE report 21685881 ↗MalfunctionJan 31, 2025Gradient Increase; Gradient Increase
MEDTRONIC RECEIVED INFORMATION THAT 2 YEARS AND 3 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS INCREASED GRADIENTS DUE TO BEING IN A HIGH FLOW STATE AND ANEMIA IN THE SETTING OF COLORECTAL CANCER. IT WAS ALSO REPORTED THAT THE VALVE IS AT A SLIGHT ANGLE, WHICH WAS DISCOVERED BY A TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) AND MAY ALSO BE CONTRIBUTING TO THE INCREASED GRADIENT. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 21287889 ↗InjuryDec 5, 2024Gradient Increase; Device Stenosis; Gradient Increase; Device Stenosis
IT WAS REPORTED, THAT A MEDTRONIC VALVE. SPECIFICALLY, THIS 25MM MOSAIC AORTIC BIOPROSTHETIC VALVE, BECAME STENOTIC. CAUSING HIGH GRADIENTS AND A VALVE PERFORMANCE ISSUE/DYSFUNCTION POST IMPLANT. THE PATIENT UNDERWENT A TRANSCATHETER AORTIC VALVE REPLACEMENT ON (B)(6) 2024, WITH THE TRANSCATHETER VALVE IMPLANTED VALVE-IN-VALVE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis
MAUDE report 20851746 ↗MalfunctionDec 4, 2024Calcified; Device Stenosis; Calcified; Device Stenosis
MEDTRONIC RECEIVED INFORMATION THAT 3 YEARS AND 9 MONTHS POST IMPLANT OF THIS AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS AORTIC STENOSIS (AS). NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED. SUBSEQUENTLY, 6 MONTHS LATER, THE PATIENT WAS EVALUATED A SECOND TIME FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS NOT REPORTED. IT WAS STATED THAT CALCIUM WAS SEEN IN THE LEFT VENTRICULAR OUTFLOW TRACT (LVOT) UNDER THE RIGHT CORONARY CUSP (RCC). NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis; Calcium Deposits/Calcification
MAUDE report 20844979 ↗InjuryJun 5, 2024Insufficient Device Problem Information; Intravalvular regurgitation; Insufficient Device Problem Information; Intravalvular regurgitation
MEDTRONIC RECEIVED INFORMATION THAT 8 YEARS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS NOT REPORTED. NO INTERVENTION OR ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Insufficient Information
MAUDE report 19467690 ↗InjuryOct 10, 2022Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 4 YEARS AND 2 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, A 26MM TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Insufficient Information
MAUDE report 15572601 ↗InjurySep 9, 2021Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT FOLLOWING THE IMPLANT OF THIS 25MM BIOPROSTHETIC AORTIC VALVE, IT WAS REPORTED THAT THERE WAS CARDIAC TAMPONADE WITH A PERICARDIAL HEMATOMA. THE TYPE OF INTERVENTION WAS NOT SPECIFIED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Cardiac Tamponade; Hematoma
MAUDE report 12451475 ↗InjuryMay 14, 2021Gradient Increase; Gradient Increase
MEDTRONIC RECEIVED INFORMATION THAT 3 YEARS AND 3 MONTHS POST IMPLANT OF THIS 25MM AORTIC BIOPROSTHETIC VALVE, A 26MM TRANSCATHETER AORTIC VALVE WAS IMPLANTED VALVE-IN-VALVE. THE REASON FOR INTERVENTION WAS DUE TO AORTIC STENOSIS THAT RESULTED IN A HIGH GRADIENT OF 42MMHG. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis
MAUDE report 11825697 ↗InjuryApr 30, 2021Perivalvular Leak; Perivalvular Leak
MEDTRONIC RECEIVED INFORMATION THAT 11 MONTHS POST IMPLANT OF THIS 25MM BIOPROSTHETIC AORTIC VALVE, IT WAS EXPLANTED AND REPLACED WITH A 27MM NON-MEDTRONIC BIOPROSTHETIC VALVE. THE REASON FOR THE REPLACEMENT WAS REPORTED AS SEVERE AORTIC STENOSIS AND A "LARGE PARAVALVULAR LEAK". NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis; Valvular Insufficiency/ Regurgitation
MAUDE report 11752900 ↗DeathDec 19, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT IMMEDIATELY AFTER IMPLANT OF THIS 27MM BIOPROSTHETIC VALVE, THE VALVE WAS EXPLANTED AND REPLACED WITH A 25MM VALVE OF A DIFFERENT MODEL. THE REASON FOR EXPLANT IS UNKNOWN. THIRTEEN DAYS POST IMPLANT, THE PATIENT DIED. THE CAUSE OF DEATH WAS NOT RECEIVED. THERE WAS NO EVIDENCE TO SUGGEST THAT THE VALVES OR THEIR FUNCTION CONTRIBUTED TO THE PATIENT¿S DEATH. IT IS UNKNOWN WHETHER AN AUTOPSY WAS PERFORMED.
Patient problems: Death
MAUDE report 8181172 ↗InjuryDec 5, 2017Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT 7 MONTHS POST IMPLANT OF THIS BIOPROSTHETIC VALVE, THE VALVE WAS EXPLANTED AND REPLACED WITH A DIFFERENT MODEL VALVE OF THE SAME SIZE. THE REASON FOR THE EXPLANT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Endocarditis; No Information
MAUDE report 7082511 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P990064. One submission often covers many models, so check the product and lot details in each record.
- Z-1881-2019 · May 21, 2019 · TerminatedMosaic 310 Bioprosthesis, Mitral, REF 310C31 - Product Usage: Replacement of malfunctioning native or prosthetic aortic and/or mitral valves.
- Z-1880-2019 · May 21, 2019 · TerminatedMosaic 310 Bioprosthesis, Mitral, REF 310C29 - Product Usage: Replacement of malfunctioning native or prosthetic aortic and/or mitral valves.
- Z-1225-2009 · Jan 26, 2009 · TerminatedMedtronic Mosaic Porcine Bioprostheses with Cinch, Heart Valve; Model 305; Catalog #s 305C21AA, 305C2701, 305C2301, 305C2501, and 305C2901; Sterile LC; Rx only; Medtronic Inc 710 M
Other heart-valve, non-allograft tissue devices
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue2 deaths404 reports
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue385 reports
- PERCEVAL PVS23Corcym Canada Corp · heart-valve, non-allograft tissue26 deaths337 reports
- MOSAIC® 305C23Medtronic, Inc. · heart-valve, non-allograft tissue327 reports
- MOSAIC® 305C25Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths324 reports
- FREESTYLE® FR995-27Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths318 reports
- FREESTYLE® FR995-29Medtronic, Inc. · heart-valve, non-allograft tissue288 reports
- FREESTYLE® FR99525Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths280 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.