Skip to content

MOSAIC® 310C31 (UDI 00643169594869)Recalls & reported problems

Medtronic, Inc. · VLV 310C31 MOSAIC MIT CINCH US PEEK · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Quick summary

This Medtronic Mosaic heart valve is an implanted replacement heart valve. Many of the 125 reports lack detailed information, and others mention heart block and valve infection. The reports include 11 deaths and 105 injuries. Reports fell to 13 in the last 12 months from 31 in the previous 12. There is 1 closed recall, from May 2019, over valves mislabeled with the wrong size.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
126
Deaths reported
11
Injuries reported
106
Recalls naming it
1

Summary

The FDA's MAUDE database contains 126 adverse event reports that list this exact device (DI 00643169594869), received between Jan 30, 2017 and Sep 9, 2026 — classified as 11 deaths, 106 injuries, 9 malfunctions.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (68 reports).

1 FDA recall record name this device's identifier.

2 other recalls cover devices cleared under the same FDA submission (P990064); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 4 reportsFeb 2024: 2 reportsMar 2024: 2 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 1 reportsJul 2024: 1 reportsAug 2024: 2 reportsSep 2024: 3 reportsOct 2024: 1 reportsNov 2024: 5 reportsDec 2024: 1 reportsJan 2025: 6 reportsFeb 2025: 5 reportsMar 2025: 4 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 3 reportsJul 2025: 1 reportsAug 2025: 2 reportsSep 2025: 2 reportsOct 2025: 2 reportsNov 2025: 2 reportsDec 2025: 1 reportsJan 2026: 1 reportsFeb 2026: 5 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520266
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. May 21, 2019Terminated

    Fifteen affected devices were distributed worldwide, which were mislabeled with an incorrect size. In all cases, the actual surgical heart valves are larger than what was indicated on the boxes and jar labels.

    Z-1881-2019 · Root cause: Labeling mix-ups · FDA record ↗

Most reported problems

Device problems

  • Insufficient Device Problem Information68
  • Patient Device Interaction Problem31
  • Adverse Event Without Identified Device or Use Problem30
  • Break5
  • Intravalvular regurgitation4
  • Perivalvular Leak4
  • Appropriate Device Problem Term/Code Not Available3
  • Inadequacy of Device Shape and/or Size3

Patient problems

  • Insufficient Information45
  • No Information23
  • Heart Block18
  • Non specific EKG/ECG Changes16
  • Endocarditis15
  • No Clinical Signs, Symptoms or Conditions9
  • Atrial Fibrillation5
  • Tricuspid Valve Insufficiency/ Regurgitation5

Recent adverse event reports

The 25 most recent of 126 reports, in the reporter's own words as published by the FDA.

  • InjurySep 9, 2026Patient Device Interaction Problem

    Medtronic received information that 2 days post implant of these 31mm Mosaic heart valves, a leadless pacemaker was implanted. The reason for the leadless pacemaker was reported as 3rd degree AV Block (AVB) and Complete Heart Block (CHB). No additional adverse patient effects were reported.

    Patient problems: Heart Block

    MAUDE report 50691492 ↗
  • InjuryMay 15, 2026Insufficient Device Problem Information; Intravalvular regurgitation

    MEDTRONIC RECEIVED INFORMATION THAT 4 YEARS AND 4 MONTHS POST IMPLANT OF THIS 31MM MOSAIC MITRAL BIOPROSTHETIC VALVE IN THE TRICUSPID POSITION, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS NOT REPORTED. INTERVENTION IS SCHEDULED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information; Tricuspid Valve Insufficiency/ Regurgitation

    MAUDE report 25182617 ↗
  • InjuryApr 27, 2026Patient Device Interaction Problem

    IT WAS REPORTED THAT 4 YEARS AND 7 MONTHS POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A LEADLESS PACEMAKER WAS IMPLANTED. THE REASON FOR THE LEADLESS PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 24999496 ↗
  • InjuryMar 20, 2026Patient Device Interaction Problem

    IT WAS REPORTED THAT 1 YEAR AND 8 MONTHS POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A LEADLESS PACEMAKER WAS IMPLANTED. THE REASON FOR THE LEADLESS PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 24647700 ↗
  • MalfunctionMar 11, 2026Leak/Splash; Unsealed Device Packaging

    MEDTRONIC RECEIVED INFORMATION THAT PRIOR TO USE OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, IT WAS REPORTED THAT WHEN THE VALVE BOX WAS OPENED, THE VALVE JAR APPEARED TO BE LEAKING. THE YELLOW TAMPER STRIP ON THE VALVE WAS CUT BY A HEALTH CARE PROFESSIONAL. THE VALVE WAS NOT USED. NO PATIENT INVOLVEMENT WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24567865 ↗
  • InjuryFeb 27, 2026Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Device Stenosis; Intravalvular regurgitation

    ADDITIONAL INFORMATION WAS RECEIVED THAT REPORTED THE REASON FOR REPLACEMENT AS TRICUSPID STENOSIS AND SEVERE TRICUSPID REGURGITATION DUE TO PROSTHETIC VALVE ENDOCARDITIS. THE ORGANISM CULTURED WAS UNKNOWN. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Endocarditis; Insufficient Information; Tricuspid Valve Insufficiency/ Regurgitation; Tricuspid Valve Stenosis

    MAUDE report 24470833 ↗
  • InjuryFeb 25, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT AN UNKNOWN DURATION POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, IT WAS EXPLANTED AND REPLACED WITH AN UNKNOWN VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 24443665 ↗
  • InjuryFeb 18, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT 5 YEARS AND 7 MONTHS POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, IT WAS EXPLANTED AND REPLACED WITH A 33MM MITRAL BIOPROSTHETIC VALVE OF THE SAME MODEL. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 24376308 ↗
  • InjuryFeb 10, 2026Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING THE IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, IT WAS EXPLANTED AND REPLACED WITH A 31MM MITRAL BI OPROSTHETIC VALVE OF THE SAME MODEL. IT WAS ALSO REPORTED THAT THE VALVE WAS WASTED AND NOT IMPLANTED IN THE PATIENT. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 24305314 ↗
  • InjuryFeb 10, 2026Patient Device Interaction Problem

    IT WAS REPORTED THAT APPROXIMATELY 1 MONTH POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 24305149 ↗
  • InjuryJan 30, 2026Perivalvular Leak; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION WAS RECEIVED THAT THE REASON FOR REPLACEMENT WAS "PARAVALVULAR LEAK DUE THE IMUNOSUPPRESANTS FOR LUPUS". IT WAS REPORTED THAT THE PHYSICIAN STATED EMPHATICALLY THAT THIS EVENT HAD NOTHING TO DO WITH THE 31MM MITRAL BIOPROSTHETIC VALVE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Autoimmune Disorder; Insufficient Information; Valvular Insufficiency/ Regurgitation

    MAUDE report 24220348 ↗
  • InjuryDec 11, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE IMPLANTED IN THE TRICUSPID POSITION ON THE SAME DAY, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS VALVE DISEASE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Non specific EKG/ECG Changes

    MAUDE report 23776194 ↗
  • DeathNov 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ADDITIONAL INFORMATION WAS RECEIVED THAT REPORTED THE PATIENTS CAUSE OF DEATH WAS CONFIRMED AS RIGHT SIDED HEART FAILURE. IT WAS ALSO REPORTED THAT THE PATIENT HAD CONTRIBUTING FACTORS SUCH AS CHRONIC RIGHT SIDED HEART FAILURE, PNEUMONIA, CONGESTIVE HEART FAILURE AND A GASTROINTESTINAL BLEED. IT WAS FURTHER NOTED THAT THE PHYSICIAN DOES NOT BELIEVE THE MEDTRONIC PRODUCT MAY HAVE CAUSED OR CONTRIBUTED TO THE PATIENT DEATH. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Failure/Congestive Heart Failure; Hemorrhage/Blood Loss/Bleeding; Insufficient Information; Pneumonia

    MAUDE report 23634272 ↗
  • InjuryNov 12, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT 2 DAYS POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE IMPLANTED IN THE TRICUSPID POSITION, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 23534758 ↗
  • InjuryOct 29, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT 4 DAYS POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 23412632 ↗
  • InjuryOct 16, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT 28 DAYS POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS INCOMPLETE ATRIOVENTRICULAR BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Non specific EKG/ECG Changes

    MAUDE report 23310937 ↗
  • DeathSep 15, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 6 YEARS AND 9 MONTHS POST IMPLANT OF THIS MOSAIC MITRAL VALVE, THE PATIENT DIED. THE CAUSE OF DEATH WAS NOT RECEIVED. THEREFORE, RELATEDNESS OF THE DEATH TO THE MOSAIC VALVE COULD NOT BE EXCLUDED. IT IS UNKNOWN WHETHER AN AUTOPSY WAS PERFORMED

    Patient problems: Insufficient Information

    MAUDE report 23050138 ↗
  • InjurySep 8, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    MEDTRONIC RECEIVED INFORMATION THAT 1 YEARS AND 5 MONTHS POST IMPLANT OF THIS 31MM MOSAIC MITRAL VALVE, IT WAS EXPLANTED AND REPLACED WITH A 33MM MOSAIC MITRAL VALVE. THE REASON FOR THE REPLACEMENT WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information

    MAUDE report 22992711 ↗
  • InjuryAug 26, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT THE SAME DAY POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE IMPLANTED IN THE TRICUSPID POSITION, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS ATRIOVENTRICULAR BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Non specific EKG/ECG Changes

    MAUDE report 22898998 ↗
  • InjuryAug 18, 2025Insufficient Device Problem Information; Intravalvular regurgitation; Insufficient Device Problem Information; Intravalvular regurgitation

    ADDITIONAL INFORMATION RECEIVED REPORTED THE REASON FOR REPLACEMENT AS TRICUSPID REGURGITATION (TR). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Insufficient Information; Tricuspid Valve Insufficiency/ Regurgitation

    MAUDE report 22825847 ↗
  • InjuryJul 28, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT 4 YEARS AND 1 MONTH POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED SICK SINUS SYNDROME. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Non specific EKG/ECG Changes

    MAUDE report 22637311 ↗
  • InjuryJun 24, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT 1 WEEK POST IMPLANT OF THIS MOSAIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS COMPLETE HEART BLOCK (CHB). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Heart Block

    MAUDE report 22318045 ↗
  • MalfunctionJun 17, 2025Packaging Problem; Packaging Problem

    IT WAS REPORTED THAT AN UNKNOWN COMPOUND WAS DISCOVERED ON THE OUTSIDE OF A MOSAIC MITRAL VALVE JAR. THE DEVICE WAS NEVER IMPLANTED. IT WAS FURTHER REPORTED THAT THE UNKNOWN COMPOUND WAS ONLY PRESENT ON THE OUTSIDE OF THE JAR. THE VALVE WAS STORED IN A CABINET WITH TEMPERATURES APPROXIMATELY 51-61 DEGREES. IT WAS STATED THAT THERE WAS NO LEAK ON THE VALVE JAR AND THE DEVICE REMAINED STERILE. NO OTHER VALVES STORED IN THIS AREA HAD THIS ISSUE. THERE WAS NO PATIENT INVOLVEMENT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22242544 ↗
  • InjuryJun 11, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT POST IMPLANT OF THIS 31MM MITRAL BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED. THE REASON FOR THE PERMANENT PACEMAKER WAS REPORTED AS SICK SINUS SYNDROME (SSS). NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Non specific EKG/ECG Changes

    MAUDE report 22186332 ↗
  • InjuryMar 11, 2025Patient Device Interaction Problem; Patient Device Interaction Problem

    MEDTRONIC RECEIVED INFORMATION THAT INDICATED THAT A PATIENT THAT WAS IMPLANTED WITH A 27MM BIOPROSTHETIC VALVE, 31MM BIOPROSTHETIC VALVE AND 32MM TRICUSPID ANNULOPLASTY BAND ALSO HAD A PERMANENT PACEMAKER OF A DIFFERENT MANUFACTURER IMPLANTED. THE REASON FOR THEPERMANENT PACEMAKER WAS NOT REPORTED. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.

    Patient problems: Non specific EKG/ECG Changes

    MAUDE report 21570800 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P990064. One submission often covers many models, so check the product and lot details in each record.

  • Z-1880-2019 · May 21, 2019 · Terminated
    Mosaic 310 Bioprosthesis, Mitral, REF 310C29 - Product Usage: Replacement of malfunctioning native or prosthetic aortic and/or mitral valves.
  • Z-1225-2009 · Jan 26, 2009 · Terminated
    Medtronic Mosaic Porcine Bioprostheses with Cinch, Heart Valve; Model 305; Catalog #s 305C21AA, 305C2701, 305C2301, 305C2501, and 305C2901; Sterile LC; Rx only; Medtronic Inc 710 M

Other heart-valve, non-allograft tissue devices

All heart-valve, non-allograft tissue devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page