Attain Ability™ MRI SureScan™ 419688 (UDI 00643169601772)Recalls & reported problems
Medtronic, Inc. · LEAD 419688 MRI CANT US · Class 3 · Implant
All models of Attain Ability MRI SureScan (4)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This is the Medtronic Attain Ability MRI SureScan, a permanent pacemaker lead placed in the heart to keep the heartbeat steady. The 73 reports mostly describe leads that fail to pace the heart or need higher thresholds, leads that shift position, and sensing that misreads heartbeats. There are no deaths, 51 injuries and 22 malfunctions, and no recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 74
- Deaths reported
- 0
- Injuries reported
- 51
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 74 adverse event reports that list this exact device (DI 00643169601772), received between Dec 9, 2016 and Sep 15, 2026 — classified as 51 injuries, 23 malfunctions.
The most frequently reported specific device problem is “High Capture Threshold” (21 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- High Capture Threshold21
- Device Dislodged or Dislocated19
- Adverse Event Without Identified Device or Use Problem18
- Failure to Capture14
- Appropriate Device Problem Term/Code Not Available10
- Capturing Problem4
- Break3
- Unstable Capture Threshold3
Patient problems
- No Known Impact Or Consequence To Patient29
- Muscle Stimulation15
- No Clinical Signs, Symptoms or Conditions11
- Unspecified Infection9
- Undesired Nerve Stimulation7
- Endocarditis2
- Syncope/Fainting2
- Wound Dehiscence2
Recent adverse event reports
The 25 most recent of 74 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 15, 2026High impedance; Impedance Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50779074 ↗InjuryAug 20, 2025High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THE PATIENT EXPERIENCED SYNCOPE. UPON REVIEW RIGHT VENTRICULAR (RV) LEAD UNDERSENSING WAS NOTED AT TIMES TRIGGERING POSSIBLE INAPPROPRIATE PACING AND THERE WERE POSSIBLE HIGH LEFT VENTRICULAR (LV) LEAD THRESHOLDS. IT WAS ALSO REPORTED THAT RIGHT ATRIAL (RA) LEAD OVERSENSING WAS NOTED ON THE STORED ELECTROGRAMS (EGM) AT TIMES TRIGGERING FALSE CLASSIFICATION OF ATRIAL TACHYCARDIA/ATRIAL FIBRILLATION (AT/AF) EPISODES AND THERE WAS A PREVIOUS FAILED ATRIAL LEAD POSITION CHECK. THE RV LEAD, RA LEAD AND LV LEAD REMAIN IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Syncope/Fainting
MAUDE report 22851853 ↗InjuryAug 18, 2025Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED BY THE PATIENT THAT DURING THE REPLACEMENT PROCEDURE, "THE LEFT VENTRICULAR (LV) LEAD WAS NOT ABLE TO GET ATTACHED AND THEY PUT A NEW ONE IN". THE PATIENT NOTED THAT THEY HAD "A HEAP OF TROUBLE" AND THAT "THEY GAVE" THE PATIENT A BLOOD CLOT. THE LEAD WAS EXPLANTED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Thrombosis/Thrombus
MAUDE report 22834782 ↗MalfunctionMar 4, 2025Failure to Capture; Failure to Capture
IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD HAD BEEN DISLODGED FOR YEARS. IT WAS ALSO NOTED THAT THE ATRIAL LEAD TRIGGERED A HIGH PACING IMPEDANCE WARNING. THE RA LEAD REMAINS IN USE. IT WAS ALSO REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD HAD BEEN PROGRAMMED OFF DUE TO A HISTORY OF NON-CAPTURE. THE LV LEAD REMAINS IN THE PATIENT. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21518609 ↗MalfunctionDec 4, 2024Under-Sensing; Capturing Problem; High Capture Threshold; Under-Sensing; Capturing Problem; High Capture Threshold
IT WAS REPORTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED UNDERSENSING THAT RESULTED IN FALSE TERMINATION OF ATRIAL TACHYCARDIA/ATRIAL FIBRILLATION (AT/AF) EPISODES. IT WAS NOTED THAT ELECTROCARDIOGRAM (ECG) DISPLAYED NUMEROUS PREMATURE VENTRICULAR CONTRACTIONS (PVC). THE LEFT VENTRICULAR (LV) LEAD EXHIBITED INCREASING AND HIGH THRESHOLDS. THE RA AND LV LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20848282 ↗MalfunctionJul 10, 2024Impedance Problem; Impedance Problem
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD TRIGGERED AN ALERT FOR AN OUT OF RANGE (OOR) IMPEDANCE. THE LV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19708308 ↗MalfunctionJun 11, 2024High impedance; High impedance
IT WAS REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD HAD A RV AND SUPERIOR VENA CAVA (SVC) DEFIBRILLATION LEAD IMPEDANCE WARNING DUE TO HIGH AND UNDEFINED IMPEDANCE MEASUREMENTS. IT WAS NOTED THAT THE RV LEAD HAD A HIGH AND UNDEFINED PACING IMPEDANCE MEASUREMENTS. IT WAS ALSO NOTED THAT THE LEFT VENTRICULAR (LV) LEAD HAD A HIGH AND UNDEFINED IMPEDANCE MEASUREMENT. BOTH LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19515196 ↗InjuryMay 22, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) WAS EXPLANTED DUE TO INFECTION WITH NOTED FEVER, AND RIGHT VENTRICULAR (RV) LEAD VEGETATION. THE ORGANISM WAS IDENTIFIED AS POSSIBLY METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS. A TEMPORARY PACING SYSTEM WAS IMPLANTED. A FEW DAYS LATER THE TEMPORARY PACING SYSTEM WAS EXPLANTED AND REPLACED WITH A LEADLESS IMPLANTABLE PULSE GENERATOR (IPG). NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Drug Resistant Bacterial Infection; Fever; Unspecified Infection
MAUDE report 19371041 ↗InjuryMay 6, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED A SYSTEMIC INFECTION. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) SYSTEM WAS EXPLANTED AND REPLACED SIX DAYS LATER. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 19254378 ↗InjuryMar 26, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS ADMITTED TO THE HOSPITAL DUE TO HEART FAILURE WITH A SEPTIC BLOOD INFECTION. THE SOURCE OF THE INFECTION WAS BACTERIAL ENDOCARDITIS. THE SEPSIS WAS TREATED WITH SIX WEEKS OF ANTIBIOTICS. AT THE TIME OF ADMISSION, A DIALYSIS PORT WAS PLACED THROUGH THE SAME VEIN THE LEADS WERE PLACED IN ¿ THE RIGHT SUBCLAVIAN VEIN. THE PHYSICIAN BELIEVED THIS DAMAGED THE RIGHT ATRIAL (RA) LEAD, CAUSING OVERSENSING AND UNDERSENSING. SMALL P WAVES OR NOISE CAUSED THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) TO NOT PROPERLY PACE AND A LOSS OF CRT PACING OCCURRED RESULTING IN BRADYCARDIA. THIS FURTHER LEAD TO HEART FAILURE, FLUID OVERLOAD, AND AN IRREGULAR HEART RHYTHM RESULTING IN SHORT-LONG-SHORT EPISODES THAT WERE PROARRHYTHMIC. THE PATIENT STOPPED THEIR ANTIARRHYTHMIC AND HIGH BLOOD PRESSURE MEDICATIONS, AND THEIR SODIUM AND POTASSIUM LEVELS WERE OUT OF RANGE, THUS, MAKING PRO-ARRYTHMIA MORE LIKELY. APPROXIMATELY FOUR WEEKS AFTER THE HOSPITAL ADMISSION, THE RA LEAD WAS REPROGRAMMED LEADING TO ONE HUNDRED PERCENT CRT PACING. IT WAS FURTHER REPORTED THAT BOTH THE ATRIAL AND RIGHT VENTRICULAR (RV) LEADS HAD VEGETATION. THE DEVICE, THE AT RIAL, RV AND
Patient problems: Endocarditis; Sepsis
MAUDE report 18978233 ↗InjuryNov 29, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED A POCKET INFECTION WITH PURULENT DISCHARGE AND PUS. THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 18231176 ↗InjuryAug 7, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED DUE TO A POCKET INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 17474267 ↗MalfunctionJun 30, 2023High Capture Threshold; High Capture Threshold
IT WAS ALSO REPORTED THAT THE LV LEAD EXHIBITED A SUDDEN RISE IN THRESHOLD.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17236601 ↗InjuryJan 5, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD SORENESS IN THE POCKET AND A SUSPECTED INFECTION. THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) SYSTEM WAS EXPLANTED. A TEMPORARY PACEMAKER WAS USED UNTIL A NEW CRT-D, RIGHT ATRIAL (RA) LEAD, AND RIGHT VENTRICULAR (RV) LEAD WAS IMPLANTED 13 DAYS LATER. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Discomfort; Unspecified Infection
MAUDE report 16103192 ↗InjuryDec 14, 2022Positioning Problem; Positioning Problem
IT WAS REPORTED THAT DURING THE GENERATOR CHANGEOUT PROCEDURE, THE ATTEMPT TO PROPHYLACTICALLY REMOVE THE RIGHT VENTRICULAR (RV) LEAD RESULTED IN PLACEMENT DIFFICULTY WITH THE LEFT VENTRICULAR (LV) AND RIGHT ATRIAL (RA) LEADS. WHILE ATTEMPTING TO EXPLANT THE RV LEAD, THE PHYSICIAN UNINTENTIONALLY PULLED OUT THE LV AND RA LEADS. A NEW SYSTEM WAS SUBSEQUENTLY IMPLANTED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15977554 ↗InjuryDec 9, 2022Capturing Problem; Unstable Capture Threshold; Capturing Problem; Unstable Capture Threshold
IT WAS REPORTED THAT THE PATIENT COMPLAINT OF SYNCOPE TWO TIMES IN THE PAST FEW MONTHS WHILE LAYING DOWN. THE PHYSICIAN SUSPECTED PATIENT WAS HAVING VERTIGO AND THE PATIENT ATTENDED PHYSICAL THERAPY WITH QUESTIONABLE RESULTS. THE RIGHT VENTRICULAR (RV) LEAD IS PROGRAMMED RV SUBTHRESHOLD SINCE SHORTLY AFTER IMPLANT DUE TO HIGH THRESHOLDS, AND SOMETIMES NO CAPTURE AT MAXIMUM OUTPUT. THE LEFT VENTRICULAR FEATURE THAT MONITORS AND CAPTURES THE PACING AMPLITUDE THRESHOLD AND ADJUSTS LV OUTPUTS, TREND DATA SHOW A BASELINE OF VARIABLE THRESHOLDS BUT MORE VARIATION IN THE PAST FEW MONTHS. THE LV LEAD WAS TESTED BUT THERE WAS A 1 VOLT DIFFERENCE IN THRESHOLD WHEN PATIENT WAS LAYING ON THE LEFT SIDE VERSUS THE RIDE SIDE. THE LEFT VENTRICULAR OUTPUT MONITOR AND CAPTURE FEATURE WAS PROGRAMMED TO MONITOR AND THRESHOLDS RE-PROGRAMMED. A REVIEW OF THE DEVICE DATA DID NOT REVEAL A LEAD INTEGRITY ISSUE, INCLUDING THE POSITIONAL THRESHOLD CHANGES. THE LV LEAD REMAINS IN USE. SUBSEQUENTLY, THE RV LEAD WAS CAPPED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions; Syncope/Fainting
MAUDE report 15955070 ↗MalfunctionFeb 4, 2022Capturing Problem; High Capture Threshold; Capturing Problem; High Capture Threshold
IT WAS REPORTED THAT LEFT VENTRICULAR (LV) LEAD EXHIBITED A RECENT JUMP IN LV THRESHOLD. THE LONGEVITY OF THE CARDIAC RESYNCHRONIZATION THERAPY DEFIBRILLATOR (CRT-D) HAS DECREASED DUE TO THE INCREASE IN LV OUTPUTS AND HIGH THRESHOLD. THE LV LEAD AND THE DEVICE REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13450828 ↗InjuryNov 1, 2021Intermittent Capture; Failure to Capture; Intermittent Capture; Failure to Capture
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD HAD NON CAPTURE AND WAS UNABLE TO CAPTURE CONSISTENTLY. THE LEAD WAS CAPPED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12728850 ↗InjuryDec 29, 2020High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THERE WAS HIGH THRESHOLD ON THE LEFT VENTRICULAR (LV) LEAD. THE LEAD WAS CAPPED AND REPLACED WITH AN EPICARDIAL LEAD. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11089459 ↗MalfunctionOct 6, 2020Failure to Capture; Unstable Capture Threshold; Failure to Capture; Unstable Capture Threshold
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD EXHIBITED VARIABLE THRESHOLDS AND SUSPECTED LOSS OF CAPTURE. THE LV LEAD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10634445 ↗InjuryFeb 26, 2020High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD WAS EXHIBITING HIGH PACING THRESHOLDS. THE LEAD WAS CAPPED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9759135 ↗InjuryFeb 19, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT APPROXIMATELY TEN DAYS FOLLOWING IMPLANT, THE PATIENT EXPERIENCED STIMULATION FROM THE LEFT VENTRICULAR (LV) LEAD. THE PHYSICIAN REPROGRAMMED THE LV PACING OUTPUT. APPROXIMATELY TWO YEARS LATER, THE PATIENT EXPERIENCED DIAPHRAGMATIC STIMULATION AND THE LV LEAD PACING CONFIGURATION WAS REPROGRAMMED. THE LV LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Muscle Stimulation
MAUDE report 9724424 ↗InjuryFeb 10, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD A POCKET INFECTION. THE LEADS WERE EXPLANTED AND LATER REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 9688907 ↗MalfunctionDec 4, 2019High Capture Threshold; High Capture Threshold
IT WAS REPORTED THAT THERE WAS A HIGH THRESHOLD ALERT ON THE LEFT VENTRICULAR (LV) LEAD. IT WAS ALSO NOTED THAT THERE WAS A RECENT INCREASE IN RIGHT VENTRICULAR (RV) LEAD THRESHOLD. THE LEADS REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9412627 ↗InjuryNov 18, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD EXPERIENCED DIAPHRAGMATIC STIMULATION FROM THE LEFT VENTRICULAR (LV) LEAD AND THAT THE LEAD WAS PROGRAMMED OFF. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Muscle Stimulation
MAUDE report 9334405 ↗
Other permanent pacemaker Electrode devices
- CapSureFix Novus MRI™ SureScan® 5076-45Medtronic, Inc. · permanent pacemaker Electrode136 deaths16,004 reports
- CapSureFix Novus MRI™ SureScan® 5076-58Medtronic, Inc. · permanent pacemaker Electrode124 deaths8,405 reports
- Capsurefix® Novus 5076-45Medtronic, Inc. · permanent pacemaker Electrode85 deaths7,050 reports
- CapSureFix Novus MRI™ SureScan™ 407652Medtronic, Inc. · permanent pacemaker Electrode69 deaths6,097 reports
- SelectSecure™ MRI SureScan™ 383069Medtronic, Inc. · permanent pacemaker Electrode56 deaths4,850 reports
- Sprint Quattro Secure® 694765Medtronic, Inc. · permanent pacemaker Electrode73 deaths3,852 reports
- Attain Performa™ MRI SureScan™ 429888Medtronic, Inc. · permanent pacemaker Electrode38 deaths3,377 reports
- CapSureFix Novus MRI™ SureScan™ 407645Medtronic, Inc. · permanent pacemaker Electrode38 deaths3,370 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page