Percepta™ CRT-P MRI SureScan™ W1TR01 (UDI 00643169891401)Recalls & reported problems
Medtronic, Inc. · CRTP W1TR01 PERCEPTA CRTP MRI US · Class 3 · Implant
All models of Percepta CRT-P MRI SureScan (2)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic Percepta CRT-P is an implanted pacemaker that paces both lower chambers of the heart. Its 300 reports mention pacing problems, early battery drain and false alarms, and some describe infections or skin erosion over the device. The reports include 4 deaths and 188 injuries. Its 1 recall, from June 2018, is closed; it concerns a timing conflict between two features that could reset the device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 300
- Deaths reported
- 4
- Injuries reported
- 187
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 300 adverse event reports that list this exact device (DI 00643169891401), received between Jul 29, 2020 and Sep 9, 2026 — classified as 4 deaths, 187 injuries, 109 malfunctions.
The most frequently reported specific device problem is “Pacing Problem” (36 reports).
1 FDA recall record name this device's identifier.
9 other recalls cover devices cleared under the same FDA submission (P010015); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Jun 21, 2018Class IITerminated
Potential for a device reset to occur in Percepta CRT-P MRI SureScan and Percepta Quad CRT-P MRI SureScan due to a timing interaction between the EffectivCRT Diagnostic and the Ventricular Safety Pacing feature (VSP).
Z-2412-2018 · Root cause: Device Design · Recall details · FDA record ↗
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem122
- Pacing Problem36
- Premature Discharge of Battery36
- Appropriate Device Problem Term/Code Not Available24
- Mechanical Problem18
- False Alarm17
- Low impedance10
- High impedance8
Patient problems
- No Clinical Signs, Symptoms or Conditions129
- Unspecified Infection84
- Bradycardia21
- Erosion21
- Bacterial Infection12
- Pain12
- Erythema11
- Discomfort10
Recent adverse event reports
The 25 most recent of 300 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 9, 2026Pacing Problem
Patient problems: Bradycardia
MAUDE report 50698197 ↗MalfunctionSep 2, 2026Device Sensing Problem
Patient problems: Tachycardia
MAUDE report 50562150 ↗MalfunctionSep 1, 2026High impedance; Device Sensing Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50539600 ↗MalfunctionAug 27, 2026Pacing Problem
It was reported that approximately six weeks post implant of a Cardiac Resynchronization Therapy Pacemaker (CRT-P) system, the CRT-P was potentially pacing below the lower rate. It was also reported that the patient experienced a fluctuating heart rate, nervousness, and fatigue. The CRT-P remains in use. No further patient complications have been reported as a result of this event.
Patient problems: Anxiety; Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Fatigue
MAUDE report 50471887 ↗InjuryAug 25, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the patient experienced an infection and fever. The Cardiac Resynchronization Therapy Pacemaker (CRT-P) and the Right Atrial (RA) lead were explanted. The epicardial Left Ventricular (LV) lead the epicardial Right Ventricular (RV) lead were partially explanted. No further patient complications have been reported as a result of this event.
Patient problems: Fever; Unspecified Infection
MAUDE report 50436231 ↗InjuryAug 19, 2026Adverse Event Without Identified Device or Use Problem
It was reported that the patient developed a Staphylococcus aureus infection. The Cardiac Resynchronization Therapy Pacemaker (CRT-P) system was explanted with no replacement. No further patient complications have been reported as a result of this event.
Patient problems: Bacterial Infection; Medical device site infection
MAUDE report 50317946 ↗MalfunctionJun 22, 2026Signal Artifact/Noise
IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED NOISE. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25574425 ↗InjuryJun 15, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED AN INFECTION AND EXPERIENCED SEPSIS AND ENTEROCOCCUS FAECALIS. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) SYSTEM WAS EXPLANTED WITH NO REPLACEMENT. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Drug Resistant Bacterial Infection; Sepsis; Unspecified Infection
MAUDE report 25498744 ↗MalfunctionJun 12, 2026False Alarm; Premature Discharge of Battery
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) TRIGGERED A FALSE LOW IMPEDANCE ALERT FOR THE RIGHT VENTRICULAR (RV) LEAD. IT WAS ALSO REPORTED THAT THE RV LEAD EXHIBITED ELEVATED CAPTURE THRESHOLDS, WHICH RESULTED IN HIGH-OUTPUT RV PACING AND CONTRIBUTING TO ACCELERATED AND LOWER THAN EXPECTED BATTERY DEPLETION. THE CRT-P AND RV LEAD REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25490876 ↗MalfunctionJun 11, 2026Premature Discharge of Battery
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) EXHIBITED PREMATURE BATTERY DEPLETION. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25467027 ↗MalfunctionJun 9, 2026Pacing Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED BRADYCARDIA. IT WAS NOTED THAT THE RIGHT ATRIAL (RA) LEAD EXHIBITED INTERMITTENT UNDERSENSING. IT WAS FURTHER NOTED THAT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED RISING/HIGH IMPEDANCE AND A LEAD FRACTURE. IT WAS ALSO NOTED THAT THE RV LEAD EXHIBITED LOW OUTPUT AND HIGH THRESHOLDS. IT WAS FURTHER NOTED THAT PACING PRIMARILY OCCURS ON THE RV LEFT BUNDLE BRANCH (LBB) LEAD. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P), RA LEAD, RV LEAD AND LBB LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bradycardia
MAUDE report 25447395 ↗MalfunctionMay 14, 2026Electromagnetic Interference
IT WAS REPORTED BY THE PATIENT THAT THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) EXHIBITED ELECTROMAGNETIC INTERFERENCE. THE CRT-P REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25170482 ↗InjuryApr 27, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED POCKET EROSION/INFECTION, DISCOMFORT, FEVER AND PAIN. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) WAS REMOVED AND REPLACED. THE LEADS WERE CAPPED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Discomfort; Erosion; Fever; Pain; Unspecified Infection
MAUDE report 24999365 ↗InjuryApr 27, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED EROSION. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) SYSTEM WAS EXPLANTED AND LATER REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Erosion
MAUDE report 24995484 ↗MalfunctionApr 23, 2026Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT A HEALTHCARE PROFESSIONAL (HCP) STATED THEY INTERROGATED A PATIENT, BUT THE REPORT WAS NOT RECEIVED FROM THE REMOTE MONITORING MOBILE APPLICATION. THEY HAD SEEN THE TRANSMISSION GOING BUT AFTER SOME TIME THE SCREEN SHOWED AS ¿START¿. TECHNICAL SUPPORT CONFIRMED THE TRANSMISSION WAS NOT RECEIVED IN THE REMOTE MONITORING NETWORK. THE HCP STATED THEY WERE GOING TO REINTERROGATE BECAUSE THE PATIENT STATED THEY RECEIVED A REPORT THAT THEIR ¿DEVICE FAILED.¿ IT WAS ADVISED TO RETRY THE INTERROGATION AND CHECK ON A DIFFERENT WIRELESS-FIDELITY (WI-FI). THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24974845 ↗InjuryApr 22, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED POCKET EROSION. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) WAS REVISED AND REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Pocket Erosion
MAUDE report 24957449 ↗MalfunctionApr 15, 2026Electromagnetic Interference
IT WAS REPORTED APPROXIMATELY TWO MONTHS POST IMPLANT THAT THE PATIENT EXPERIENCED CHEST PAIN. IT WAS ALSO REPORTED THAT THE THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED ELECTROMAGNETIC INTERFERENCE/NOISE. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Chest Pain
MAUDE report 24881453 ↗InjuryApr 9, 2026Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT ONE DAY POST IMPLANT THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED OUT OF RANGE (OOR) HIGH IMPEDANCE, VARYING IMPEDANCE, INTERMITTENT CAPTURE, NO CAPTURE, HIGH THRESHOLDS AND LEAD PERFORATION. THE PATIENT EXPERIENCED CHEST PAIN AND PLEURAL EFFUSION RELATED TO THE RV LEAD AND CRT-P. REPROGRAMMING WAS PERFORMED. TWO DAYS LATER IT WAS REPORTED THAT THERE WAS ANOTHER RV LEAD PERFORATION AND THAT THE LEFT VENTRICULAR (LV) LEFT BUNDLE BRANCH LEAD DISLODGED - EXTRAVASCULAR LEAD ANCHOR SLEEVE SLIPPAGE. THE RV AND LV LEADS WERE EXPLANTED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Chest Pain; Pleural Effusion
MAUDE report 24828317 ↗InjuryApr 8, 2026Premature Discharge of Battery
IT WAS FURTHER REPORTED THAT NO PERFORMANCE ISSUES WERE NOTED AGAINST THE LV LEAD. THE LV LEAD REMAINS IN USE. THE RV SHOWED OVERSENSING. THE RV LEAD WAS CAPPED AND REPLACED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24813487 ↗MalfunctionApr 3, 2026Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT THE IMPLANTABLE PULSE GENERATOR (IPG) EXHIBITED A LEFT VENTRICULAR (LV) LEAD TIP TO CAN ISSUE. THE IPG REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24777458 ↗DeathApr 2, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY THE PATIENT'S REPRESENTATIVE THAT THE PATIENT IS DECEASED. THE PATIENT EXPERIENCED AN INFECTION. THE IMPLANTABLE PULSE GENERATOR (IPG) SYSTEM WAS REPLACED WITH A CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P). THREE DAYS FOLLOWING THE REPLACEMENT THE PATIENT DIED.
Patient problems: Insufficient Information
MAUDE report 24764710 ↗InjuryApr 1, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED PAIN, A POCKET INFECTION AND EROSION. THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) WAS EXPLANTED AND REPLACED WITH A LEADLESS IMPLANTABLE PULSE GENERATOR (IPG). NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Erosion; Medical device site infection; Pain; Unspecified Infection
MAUDE report 24752061 ↗InjuryMar 19, 2026Pacing Problem; Device Sensing Problem
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P,) DETECTED VENTRICULAR TACHYCARDIA (VT) THAT WAS SUSPECTED TO BE SUPRA VENTRICULAR TACHYCARDIA (SVT) OR DUAL TACHYCARDIA. REVIEW OF THE ELECTROGRAMS (EGM) CONFIRM ATRIAL RATES BELOW THE LOWER RATE LIMIT (LRL). IN ADDITION, THE RIGHT ATRIAL (RA) LEAD EXHIBITED UNDERSENSING DURING ATRIAL TACHYCARDIA/ATRIAL FIBRILLATION (AT/AF) EVENTS RESULTING IN UNNECESSARY/INAPPROPRIATE ATRIAL PACING AT TIMES. IN ADDITION, LOW P-WAVES WERE NOTED. THE CRT-P AND RA LEAD REMAIN IN USE. THE PATIENT ALSO EXPERIENCED SYNCOPE WITH A HEART RATE OF 38BPM.
Patient problems: Bradycardia; Syncope/Fainting; Tachycardia
MAUDE report 24640480 ↗InjuryMar 18, 2026Premature Discharge of Battery
IT WAS REPORTED THAT THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P) EXHIBITED PREMATURE BATTERY DEPLETION. THE CRTP WAS EXPLANTED AND REPLACED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24625325 ↗InjuryMar 11, 2026Premature Discharge of Battery
IT WAS REPORTED BY THE PATIENT THAT THEIR LEFT BUNDLE BRANCH (LBB) LEAD EXHIBITED HIGH THRESHOLDS WHICH CONTRIBUTED TO PREMATURE BATTERY DEPLETION OF THE CARDIAC RESYNCHRONIZATION THERAPY PACEMAKER (CRT-P). THE LBB LEAD AND CRT-P WERE REPROGRAMMED AND REMAIN IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24575254 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P010015. One submission often covers many models, so check the product and lot details in each record.
- Z-2128-2025 · Jun 17, 2025 · Open, ClassifiedMedtronic SmartLink software loaded on CareLink SmartSync Device Manager, Model Number 24967A with the following software components: 1. Azure Astra application, Software Model N
- Z-2127-2025 · Jun 17, 2025 · Open, ClassifiedMedtronic SmartLink Software loaded on SmartSync Patient Connector, Model Number 24967 with the following software components: 1. Azure Astra application, Software Model Number D
- Z-2511-2020 · Jun 4, 2020 · Open, ClassifiedPercepta CRT-P MRI, Model Numbers: a) W1TR01, b) W1TR04, c) W4TR01, d) W4TR04
- Z-2512-2020 · Jun 4, 2020 · Open, ClassifiedSerena CRT-P MRI, Model Numbers: a) W1TR02, b) W1TR05, c) W4TR02, d) W4TR05
- Z-2513-2020 · Jun 4, 2020 · Open, ClassifiedSolara CRT-P MRI, Model Numbers: a) W1TR03, b) W1TR06, c) W4TR03, d) W4TR06
- Z-2413-2018 · Jun 21, 2018 · TerminatedPercepta Quad CRT-P MRI SureScan, REF W4TR01 Product Usage: The CRT-P models are implantable pulse generators with cardiac resynchronization therapy (CRT-P). These devices monitor
- Z-2415-2018 · Jun 21, 2018 · TerminatedPercepta Quad CRT-P MRI SureScan, REF W4TR04 Product Usage: The CRT-P models are implantable pulse generators with cardiac resynchronization therapy (CRT-P). These devices monitor
- Z-2414-2018 · Jun 21, 2018 · TerminatedPercepta CRT-P MRI SureScan, REF W1TR04 Product Usage: The CRT-P models are implantable pulse generators with cardiac resynchronization therapy (CRT-P). These devices monitor and
- Z-0342-2016 · Nov 9, 2015 · TerminatedMedtronic InSync III, model 8042, 8042B and 8042U. Implantable pulse generator pacemaker.
Other Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P) devices
- VALITUDE™ X4 CRT-P U128Boston Scientific Corporation · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)2 recalls26 deaths2,073 reports
- Quadra Allure MP™ PM3562St. Jude Medical, Inc. · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)26 deaths1,180 reports
- Percepta™ Quad CRT-P MRI SureScan™ W4TR01Medtronic, Inc. · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)1 recall28 deaths897 reports
- VISIONIST™ X4 CRT-P U228Boston Scientific Corporation · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)1 recall4 deaths819 reports
- Percepta™ Quad CRT-P MRI SureScan™ W4TR01Medtronic, Inc. · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)1 recall8 deaths703 reports
- INVIVE™ V173Boston Scientific Corporation · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)1 death670 reports
- VALITUDE™ CRT-P U125Boston Scientific Corporation · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)2 recalls2 deaths558 reports
- QUADRA ALLURE MP™ PM3262St. Jude Medical, Inc. · Pulse generator, pacemaker, implantable, with cardiac resynchronization (CRT-P)27 deaths518 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page