1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169962057), received between Oct 11, 2023 and Oct 11, 2023 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Spinal Cord Injury1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 11, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING COCHLEAR IMPLANT PROCEDURE, BURR TIP SKIDDED CAUSING THE SURGEON TO ACCIDENTALLY DRILL THROUGH THE PATIENT'S DURA. IT WAS ALSO REPORTED THAT THE SURGEON HAD TO REPAIR THE PATIENT'S DURA AND THE PROCEDURE WAS COMPLETED WITH BACKUP PRODUCT(S). ON FOLLOW IT WAS REPORTED THAT THERE WAS AROUND 30MINS DELAY, DELAY WAS RESULTED AS A RESULT OF REPAIRING OF DURA. PATIENT IS GENERALLY ALRIGHT AND DOING WELL AFTER THE OPERATION, BUT FACED SOME SIDE EFFECTS FOR AROUND 2 WEEKS AFTER THE OPERATION.

    Patient problems: Spinal Cord Injury

    MAUDE report 17911563 ↗

Other DRILLS, BURRS, TREPHINES & ACCESSORIES (SIMPLE, POWERED) devices