CD HORIZON® Spinal System 859-645Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCREW 859-645 5.5 FIXED ANGLE 6.5X45 TI · Class 2 · Implant
All models of CD HORIZON Spinal System (341)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00673978063522), received between Nov 15, 2016 and Oct 4, 2017 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Device Inoperable1
- Failure to Align1
Patient problems
- No Known Impact Or Consequence To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 4, 2017Device Inoperable; Device Inoperable
PROCEDURE: POSTERIOR REDUCTION AND INTERNAL FIXATION AND SPINAL DECOMPRESSION IT WAS REPORTED THAT THE PATIENT UNDERWENT SPINAL SURGERY DUE TO L3 VERTEBRAL BURST FRACTURES. DURING SURGERY, HEAD OF THE IMPLANTED SCREW WAS DAMAGED. THE THREADS WERE DAMAGED AND SO THE SCREW WAS REMOVED. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6914480 ↗MalfunctionJul 28, 2017Break; Break
IT WAS REPORTED THAT PATIENT WITH PRE OPERATIVE DIAGNOSIS OF "WAIST 4,5 DISC PROLAPSE, WITH 1 DEGREE SLIPPAGE" UNDERWENT LUMBAR POSTERIOR OPEN FUSION. INTRA-OP, THE SCREW BROKE. NO FRAGMENT OF THE BROKEN SCREW REMAINED INSIDE THE PATIENT. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6749714 ↗MalfunctionNov 15, 2016Failure to Align; Failure to Align
IT WAS REPORTED THAT DURING AN UNSPECIFIED PROCEDURE, THE DOCTOR FOUND THAT THE PRODUCT SLIPPED. DOCTOR REPLACED THE SLIPPED PRODUCT WITH A NEW ONE TO COMPLETE THE SURGERY. THE PRODUCT CAME IN CONTACT WITH THE PATIENT. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6101331 ↗
FDA clearance and classification
Cleared through 510(k) K961633 on Dec 5, 1996 (decision: Substantially Equivalent for Some Indications). Submitted by Sofamor Danek USA,Inc. as “Cd Horizon Spinal System”. The FDA review took 220 days. FDA record ↗
The FDA regulates product code MNH (orthosis, spondylolisthesis spinal fixation) under 21 CFR 888.3070 as a Class II device. 21 CFR 888.3070 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CD HORIZON® Spinal System 859-645
Has the CD HORIZON® Spinal System 859-645 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00673978063522), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CD HORIZON® Spinal System 859-645?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Nov 15, 2016 and Oct 4, 2017. In those reports, the most common specific device problems are “Break” (1), “Device Inoperable” (1) and “Failure to Align” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CD HORIZON® Spinal System 859-645?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CD HORIZON® Spinal System 859-645 FDA approved?
It was cleared through 510(k) K961633 on Dec 5, 1996. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Is the CD HORIZON® Spinal System 859-645 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the CD HORIZON® Spinal System 859-645, and is it still sold?
The FDA's device database lists Medtronic Sofamor Danek, Inc. as the company responsible for it (brand CD HORIZON® Spinal System, model 859-645). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Orthosis, spondylolisthesis spinal fixation devices
- CD HORIZON® Spinal System 7540020Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation257 reports
- MANTIS Redux 48289999Stryker Corporation · Orthosis, spondylolisthesis spinal fixation76 reports
- EXPEDIUM TOP NOTCH 179771555Depuy Spine, LLC · Orthosis, spondylolisthesis spinal fixation41 reports
- EXPEDIUM 179712650Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation31 reports
- XIA 4 5 48130000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation29 reports
- EXPEDIUM VERSE 199721530Medos International Sàrl · Orthosis, spondylolisthesis spinal fixation29 reports
- XIA 4.5 System - XIA CT 48850000Stryker Corporation · Orthosis, spondylolisthesis spinal fixation27 reports
- CD HORIZON® Spinal System 7576545Medtronic Sofamor Danek, Inc. · Orthosis, spondylolisthesis spinal fixation26 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page