SureFlex Steerable Guiding Sheath TSK85-32-BD-71M (UDI 00685447001683)Recalls & reported problems
Baylis Médicale Cie Inc · SureFlex Steerable Sheath; Transseptal Dilator; J-Tip Guidewire · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00685447001683), received between Oct 11, 2019 and Oct 11, 2019 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Pericardial Effusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 11, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AFTER COMPLETION OF A PROCEDURE IN WHICH THE SUREFLEX STEERABLE GUIDING SHEATH KIT WAS USED, A PERICARDIAL EFFUSION OCCURRED. IT WAS NOTED THAT THE PATIENT HAD A ROTATED CARDIAC ANATOMY WITH PERSISTENT ATRIAL FIBRILLATION (AF) AND THE LEFT ATRIUM (LA) WAS DESCRIBED AS LARGE. THE PHYSICIAN ENGAGED THE INTERATRIAL SEPTUM WITH THE BRK NEEDLE THROUGH THE SUREFLEX SHEATH. AFTER MULTIPLE EXTENSIONS OF THE NEEDLE, TRANSSEPTAL ACCESS WAS OBTAINED. THE SUREFLEX DILATOR FOLLOWED THE NEEDLE INTO THE LA BUT THE SHEATH WAS UNABLE TO BE ADVANCED SMOOTHLY. AFTER MULTIPLE ATTEMPTS, THE PHYSICIAN MAINTAINED TRANSSEPTAL ACCESS WITH A J-WIRE AND WITHDREW THE SUREFLEX SHEATH FROM THE BODY. THE PHYSICIAN ATTEMPTED TO PLACE A HEARTSPAN FIXED CURVE SHEATH OVER THE WIRE INTO THE LA BUT IT WAS UNABLE TO BE ADVANCED. HE REMOVED THE HEARTSPAN AND USED A LAMP 45 OVER THE J-WIRE, WHICH WAS ABLE TO BE ADVANCED TO THE LA. THE PHYSICIAN ATTEMPTED AGAIN TO ACCESS WITH THE SUREFLEX. THE PHYSICIAN LOADED THE BRK THROUGH AND ENGAGED THE SEPTUM AT A LOCATION CLOSE TO THE FIRST TRANSSEPTAL PUNCTURE. ON THIS ATTEMPT, THE BRK PUNCTURED WITH EASE AND THE SUREFLEX DILATOR AND SHEATH CROSSED SMOOTHLY INTO THE LA. THE PHYSIC
Patient problems: Pericardial Effusion
MAUDE report 9182672 ↗
Other Introducer, Catheter devices
- VIZIGO D138502Biosense Webster Inc · INTRODUCER, CATHETER2 recalls4 deaths2,839 reports
- VIZIGO D138501Biosense Webster Inc · INTRODUCER, CATHETER2 recalls2 deaths2,005 reports
- Swartz™ 407451St. Jude Medical, Inc. · INTRODUCER, CATHETER5 deaths728 reports
- Edwards eSheath+ Introducer set 914ESPEdwards Lifesciences LLC · Introducer, Catheter22 deaths532 reports
- Fast-Cath™ 406849St. Jude Medical, Inc. · INTRODUCER, CATHETER420 reports
- VIZIGO D138503Biosense Webster Inc · INTRODUCER, CATHETER362 reports
- Agilis™ G408318St. Jude Medical, Inc. · INTRODUCER, CATHETER333 reports
- Agilis™ NxT Steerable Introducer Dual-Reach™ SI-1371-MSt. Jude Medical, Inc. · Introducer, catheter1 death301 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.