VersaCross RF Wire VXW-35-230-P-WMRecalls & reported problems

Boston Scientific Corporation · 1 x VersaCross RF Wire; 1 x Connector Cable (Single Use) · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00685447011118), received between Jan 6, 2023 and Jan 6, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Connection Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Connection Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 6, 2023Connection Problem; Connection Problem

    A 20-MINUTE PROCEDURAL WAS REPORTED FOR THE VERSACROSS RF WIRE KIT (CONTAINING THE VERSACROSS RF WIRE AND AN RFP-100A CONNECTOR CABLE (CONNECTOR CABLE)) WHERE THE CONNECTOR CABLE WAS NOT ABLE TO ESTABLISH A CONNECTION WHEN CONNECTED TO THE VERSACROSS RF WIRE AND COMPATIBLE RF GENERATOR DURING A LEFT-ATRIAL APPENDAGE CLOSURE (LAAC) PROCEDURE. WHILE ATTEMPTING TO COMPLETE THE TRANSSEPTAL PUNCTURE, THE VERSACROSS WIRE WAS POSITIONED ON THE SEPTUM AND WAS THEN CONNECTED TO THE GENERATOR THROUGH THE CONNECTOR CABLE. HOWEVER, THE GENERATOR DID NOT RECOGNIZE THAT THE DEVICE WAS CONNECTED. THE CONNECTOR CABLE WAS DISCONNECTED AND RECONNECTED, HOWEVER, THE GENERATOR STILL DID NOT DETECT THE DEVICE. THE GROUNDING PAD THAT WAS CONNECTED TO THE GENERATOR WAS ALSO SWAPPED OUT AND THE GENERATOR WAS REPLACED WITH A SECOND GENERATOR. HOWEVER, THE ISSUE CONTINUED TO PERSIST. AN NRG TRANSSEPTAL NEEDLE AND CONNECTOR CABLE (BAYLIS MEDICAL COMPANY INC.) WERE OPENED AND CONNECTED TO THE FIRST GENERATOR AND THE TRANSSEPTAL PUNCTURE WAS SUCCESSFULLY COMPLETED. WHILE THERE WAS NO PATIENT INJURY REPORTED, BAYLIS MEDICAL COMPANY INC. HAS DECIDED TO REPORT THIS EVENT DUE TO THE PROCEDURAL DELAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16117816 ↗

Other Catheter, Septostomy devices

All Catheter, Septostomy devices →