VersaCross Access Solution VXSK0033 (UDI 00685447017363)Recalls & reported problems
Baylis Médicale Cie Inc · 1 x VersaCross Transseptal Sheath (including 1 x J-tip Guidewire); 1 x VersaCross RF Wire (including 1 x Connector Cable (Single Use)) · Class 2
All models of VersaCross Access Solution (19)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00685447017363), received between Jun 9, 2025 and Jun 9, 2025 — classified as 2 injuries.
The most frequently reported specific device problem is “Positioning Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Positioning Problem1
Patient problems
- Pericardial Effusion2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 9, 2025Positioning Problem; Positioning Problem
IT WAS REPORTED A PERICARDIAL EFFUSION (PE) WAS NOTED. DURING A LEFT ATRIAL APPENDAGE CLOSURE (LAAC) PROCEDURE, A VERSACROSS ACCESS SOLUTION WAS SELECTED FOR USE. THERE WAS A TRACE EFFUSION NOTED BEFORE THE PROCEDURE STARTED AND IT WAS LOCATED AT THE APEX OF THE HEART. THE VERSACROSS WIRE WAS INSERTED IN THE SUPERIOR VENA CAVA (SVC), WITH THE SHEATH TO FOLLOW. THE PHYSICIAN BROUGHT THE WHOLE SYSTEM DOWN ONTO THE SEPTUM IN ORDER TO GET IN THE RIGHT POSITION TO CROSS AND GO INTO THE LEFT ATRIUM (LA). IN THE PROCESS OF TRYING TO GET THE CORRECT PLACEMENT ON THE SEPTUM THE ACCESS SYSTEM WAS PLACED IN THE RIGHT ATRIAL APPENDAGE AND THEN DROPPED ONTO THE SEPTUM. THE PHYSICIAN WENT TO CROSS THE SEPTUM AND HEAD INTO THE LEFT ATRIUM. ONCE ACROSS THE LEFT ATRIUM, THE RF WIRE WAS INSERTED INTO THE LEFT ATRIAL APPENDAGE AND THE VERSACROSS SYSTEM WAS TAKEN OUT, NEXT THE WATCHMAN DOUBLE CURVE SHEATH WAS INSERTED. ONCE THE DOUBLE CURVE WAS INSERTED THE NON-BOSTON SCIENTIFIC PIGTAIL CATHETER OVER THE RF WIRE AND THE WIRE WAS TAKEN OUT. LA PRESSURE WAS OBTAINED AT THIS POINT, AND A CONTRAST SHOT WAS TAKEN OF THE LEFT ATRIAL APPENDAGE TO DETERMINE WHAT SIZE WATCHMAN DEVICE. THE DEVICE WAS PREPPED, T
Patient problems: Pericardial Effusion
MAUDE report 22170061 ↗InjuryJun 9, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED A PERICARDIAL EFFUSION (PE) WAS NOTED. DURING A LEFT ATRIAL APPENDAGE CLOSURE (LAAC) PROCEDURE, A VERSACROSS ACCESS SOLUTION WAS SELECTED FOR USE. THERE WAS A TRACE EFFUSION NOTED BEFORE THE PROCEDURE STARTED AND IT WAS LOCATED AT THE APEX OF THE HEART. THE VERSACROSS WIRE WAS INSERTED IN THE SUPERIOR VENA CAVA (SVC), WITH THE SHEATH TO FOLLOW. THE PHYSICIAN BROUGHT THE WHOLE SYSTEM DOWN ONTO THE SEPTUM IN ORDER TO GET IN THE RIGHT POSITION TO CROSS AND GO INTO THE LEFT ATRIUM (LA). IN THE PROCESS OF TRYING TO GET THE CORRECT PLACEMENT ON THE SEPTUM THE ACCESS SYSTEM WAS PLACED IN THE RIGHT ATRIAL APPENDAGE AND THEN DROPPED ONTO THE SEPTUM. THE PHYSICIAN WENT TO CROSS THE SEPTUM AND HEAD INTO THE LEFT ATRIUM. ONCE ACROSS THE LEFT ATRIUM, THE RF WIRE WAS INSERTED INTO THE LEFT ATRIAL APPENDAGE AND THE VERSACROSS SYSTEM WAS TAKEN OUT, NEXT THE WATCHMAN DOUBLE CURVE SHEATH WAS INSERTED. ONCE THE DOUBLE CURVE WAS INSERTED THE NON-BOSTON SCIENTIFIC PIGTAIL CATHETER OVER THE RF WIRE AND THE WIRE WAS TAKEN OUT. LA PRESSURE WAS OBTAINED AT THIS POINT, AND A CONTRAST SHOT WAS TAKEN OF THE LEFT ATRIAL APPENDAGE TO DETERMINE WHAT SIZE WATCHMAN DEVICE. THE DEVICE WAS PREPPED, T
Patient problems: Pericardial Effusion
MAUDE report 22170008 ↗
FDA clearance and classification
The FDA regulates product code DXF (catheter, septostomy) under 21 CFR 870.5175 as a Class II device. 21 CFR 870.5175 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the VersaCross Access Solution VXSK0033
Has the VersaCross Access Solution VXSK0033 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00685447017363), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the VersaCross Access Solution VXSK0033?
The FDA's MAUDE database lists 2 adverse event reports for this device, received on Jun 9, 2025. In those reports, the most common specific device problem is “Positioning Problem” (1); the most common patient problem is “Pericardial Effusion” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the VersaCross Access Solution VXSK0033?
None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the VersaCross Access Solution VXSK0033, and is it still sold?
The FDA's device database lists Baylis Médicale Cie Inc as the company responsible for it (brand VersaCross Access Solution, model VXSK0033). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, Septostomy devices
- VersaCross Access Solution VXSK0031Baylis Médicale Cie Inc · Catheter, Septostomy1 recall16 reports
- VersaCross Access Solution VXSK0021Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 death15 reports
- VersaCross Access Solution VXSK0032Baylis Médicale Cie Inc · Catheter, Septostomy1 recall14 reports
- VersaCross Access Solution VXSK0022Baylis Médicale Cie Inc · Catheter, Septostomy1 recall13 reports
- VersaCross Access Solution VXSK0024Baylis Médicale Cie Inc · Catheter, Septostomy1 recall3 reports
- VersaCross Access Solution VXSK0034Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- VersaCross Access Solution VXSK0025Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- NRG Transseptal Needle NRG-E-HF-71-C0Boston Scientific Corporation · Catheter, Septostomy22 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.