VersaCross Large Access Solution VLAK0010Recalls & reported problems
Baylis Médicale Cie Inc · 1 x VersaCross Large Access Transseptal Dilator (including 1 x J-tip Mechanical Guidewire); 1 x VersaCross RF Wire (including 1 x Connector Cable (Single Use)) · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00685447017530), received between Dec 11, 2024 and Dec 11, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Advance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Advance1
- Material Deformation1
- Physical Resistance/Sticking1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 11, 2024Difficult to Advance; Material Deformation; Physical Resistance/Sticking; Difficult to Advance; Material Deformation; Physical Resistance/Sticking
IT WAS REPORTED THAT VERSACROSS LARGE ACCESS SOLUTION WAS SELECTED FOR USE. DURING THE PROCEDURE, IT WAS MENTIONED THAT WHEN THE BMC RF GENERATOR WAS TURNED ON AND ATTEMPT WERE MADE FOR TRANSSEPTAL, BUT IT FAILED. IT CROSSED IN THE SECOND ATTEMPT AND THE SHEATH WAS ADVANCED. WHEN THE PHYSICIAN TRIED TO PULL BACK THE VERSACROSS RF WIRE INTO THE DILATOR, IT FELT IT GOT STUCK INTO THE DILATOR (BUT NOT INTO THE PATIENT BODY), SO THE VERSACROSS RF WIRE WAS READVANCED INTO THE DILATOR. NO VISIBLE OBSTRUCTION WAS NOTED WHEN THE VERSACROSS RF WIRE WHEN VISUALIZED ON INTRACARDIAC ECHOCARDIOGRAPHY (ICE) IN LEFT SUPERIOR PULMONARY VEIN (LSPV). THE PHYSICIAN APPLIED FORCE BACK TO THE DILATOR, AND THE VERSACROSS RF WIRE WAS NOTED TO BE KNOTTED AT ITS TIP. THUS, THE DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO PATIENT COMPLICATIONS WERE REPORTED. THE DEVICE IS EXPECTED TO BE RETURN FOR ANALYSIS. NO OTHER ISSUE WAS REPORTED DURING TRANSSEPTAL PORTION NOR PREPARATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20901963 ↗
Other Catheter, Septostomy devices
- VersaCross Access Solution VXSK0031Baylis Médicale Cie Inc · Catheter, Septostomy1 recall16 reports
- VersaCross Access Solution VXSK0021Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 death15 reports
- VersaCross Access Solution VXSK0032Baylis Médicale Cie Inc · Catheter, Septostomy1 recall14 reports
- VersaCross Access Solution VXSK0022Baylis Médicale Cie Inc · Catheter, Septostomy1 recall13 reports
- VersaCross Access Solution VXSK0024Baylis Médicale Cie Inc · Catheter, Septostomy1 recall3 reports
- VersaCross Access Solution VXSK0034Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- VersaCross Access Solution VXSK0025Baylis Médicale Cie Inc · Catheter, Septostomy1 recall1 report
- NRG Transseptal Needle NRG-E-HF-71-C0Boston Scientific Corporation · Catheter, Septostomy22 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page