Skip to content

FOGARTY 120804FRecalls & reported problems

Edwards Lifesciences LLC · FOGARTY ARTERIAL EMBOLECTOMY CATHETER 4F 80CM · Class 2

Adverse event reports
7
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00690103043303), received between Feb 14, 2019 and Aug 20, 2024 — classified as 2 injuries, 5 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 1 reportsAug 2024: 3 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component5
  • Break2
  • Failure to Deflate1

Patient problems

  • Foreign Body In Patient2
  • No Clinical Signs, Symptoms or Conditions2
  • Device Embedded In Tissue or Plaque1
  • Insufficient Information1
  • No Known Impact Or Consequence To Patient1
  • Vascular Dissection1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 20, 2024Failure to Deflate; Failure to Deflate

    AS REPORTED, WHEN INSERTING THIS FOGARTY EMBOLECTOMY CATHETER DURING AN ENDOVASCULAR SURGERY, AFTER INFLATING THE BALLOON, THE BALLOON SLIPPED TO THE TIP OF THE CATHETER AND COULD NOT BE DEFLATED. THERE WAS A DISSECTION OF AN ARTERY AND THE INTERVENTION WAS PROLONGED. NO FURTHER INFORMATION PROVIDED. PATIENT DEMOGRAPHICS WERE UNABLE TO BE OBTAINED.

    Patient problems: Insufficient Information; Vascular Dissection

    MAUDE report 20007062 ↗
  • MalfunctionAug 14, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE PATIENT WAS IN THE OR FOR A RIGHT AXILLARY BILATERAL FEMORAL THROMBECTOMY WITH ANGIOGRAM. A 4FR FOGARTY CATHETER WAS USED DURING ANGIOGRAM. THE PROVIDER PLACED THE FOGARTY CATHETER IN PATIENTS RIGHT LEG AND INFLATED THE BALLOON AS INDICATED ON THE PACKAGING AND CONFIRMED WITH X-RAY. WHEN THE CATHETER WAS REMOVED IT WAS DISCOVERED THAT THE BALLOON WAS NOT INTACT ON THE CATHETER AND HAD BEEN DISPLACED INSIDE OF THE PATIENT. PROVIDER STATED THAT THE FIRST BALLOON GOT HUNG UP ON WHAT SHE BELIEVES TO BE THE CHRONIC OCCLUDED PLAQUE. SHE HAD TO PULL HARD AND THE BALLOON BROKE AWAY FROM THE CATHETER AND WAS LEFT BEHIND. SHE THEN USED A SECOND BALLOON TO RETRIEVE THE FIRST AND THE EXACT SAME THING HAPPENED SO SHE DID NOT TRY AGAIN. TWO BALLOONS WERE LEFT BEHIND IN THE PATIENT. PROVIDER ALSO STATED THAT IN HER OPINION THE BALLOONS ARE NOT CAUSING ANY OCCLUSION BECAUSE THE VESSEL WAS ALREADY OCCLUDED. THERE WAS NO ALLEGATION OF PATIENT INJURY. DURING SET UP, THE INFLATION TEST WAS COMPLETED WITHOUT ISSUE. THE TWO BALLOONS ARE STILL INSIDE THE PATIENT. THIS COMPLAINT CAPTURES THE SECOND FOGARTY CATHETER USED IN THIS CASE. DEVICE WAS DISCARDED AFTER USE.

    Patient problems: Foreign Body In Patient

    MAUDE report 19986719 ↗
  • MalfunctionAug 14, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT THE PATIENT WAS IN THE OR FOR A RIGHT AXILLARY BILATERAL FEMORAL THROMBECTOMY WITH ANGIOGRAM. A 4FR FOGARTY CATHETER WAS USED DURING ANGIOGRAM. THE PROVIDER PLACED THE FOGARTY CATHETER IN PATIENTS RIGHT LEG AND INFLATED THE BALLOON AS INDICATED ON THE PACKAGING AND CONFIRMED WITH X-RAY. WHEN THE CATHETER WAS REMOVED IT WAS DISCOVERED THAT THE BALLOON WAS NOT INTACT ON THE CATHETER AND HAD BEEN DISPLACED INSIDE OF THE PATIENT. PROVIDER STATED THAT THE FIRST BALLOON GOT HUNG UP ON WHAT SHE BELIEVES TO BE THE CHRONIC OCCLUDED PLAQUE. SHE HAD TO PULL HARD AND THE BALLOON BROKE AWAY FROM THE CATHETER AND WAS LEFT BEHIND. SHE THEN USED A SECOND BALLOON TO RETRIEVE THE FIRST AND THE EXACT SAME THING HAPPENED SO SHE DID NOT TRY AGAIN. TWO BALLOONS WERE LEFT BEHIND IN THE PATIENT. PROVIDER ALSO STATED THAT IN HER OPINION THE BALLOONS ARE NOT CAUSING ANY OCCLUSION BECAUSE THE VESSEL WAS ALREADY OCCLUDED. THERE WAS NO ALLEGATION OF PATIENT INJURY. DURING SET UP, THE INFLATION TEST WAS COMPLETED WITHOUT ISSUE. THE TWO BALLOONS ARE STILL INSIDE THE PATIENT. THIS COMPLAINT CAPTURES THE FIRST FOGARTY CATHETER USED IN THIS CASE. DEVICE WAS DISCARDED AFTER USE.

    Patient problems: Foreign Body In Patient

    MAUDE report 19986064 ↗
  • MalfunctionJul 23, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED, WHEN BRINGING THIS FOGARTY CATHETER OUT FROM PATIENT, WHICH WAS USED FOR A BLOCKED FEMORAL ARTERY, THE BALLOON DETACHED FROM THE CATHETER, LEAVING IT INSIDE THE PATIENT. THERE WAS NO ALLEGATION OF PATIENT INJURY. THE DEVICE WAS AVAILABLE FOR EVALUATION. PATIENT DEMOGRAPHICS UNABLE TO BE OBTAINED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19803813 ↗
  • MalfunctionJun 28, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING AN AXILLARY BIFEMORAL BYPASS PROCEDURE THE BALLOON BECAME DETACHED FROM A FOGARTY 4FR MODEL 120804F CATHETER AND WAS RETAINED IN THE PATIENT. THE PROCEDURE WAS COMPLETED WITH A NEW FOGARTY CATHETER. PER THE CUSTOMER, IT WAS DETERMINED THAT NO ADDITIONAL PROCEDURE WAS PERFORMED BASED ON RISK TO THE PATIENT. THERE WAS NO ALLEGATION OF PATIENT INJURY. THE DEVICE IS NOT AVAILABLE FOR RETURN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19635784 ↗
  • MalfunctionJun 12, 2020Break

    FROM STAFF: WHILE USING A FOGARTY EMBOLECTOMY CATHETER THE TIP BROKE OFF IN THE PATIENT. THE TIP WAS RETRIEVED BY THE SURGEON.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 10147895 ↗
  • InjuryFeb 14, 2019Break; Detachment of Device or Device Component

    THE BALLOON ON THE FOGARTY CATHETER BROKE AND REMAINED INSIDE THE PATIENT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 8343631 ↗

Other CATHETER, EMBOLECTOMY devices

All CATHETER, EMBOLECTOMY devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.