FOGARTY HYDRAJAW HYDRA86Recalls & reported problems

Edwards Lifesciences LLC · FOGARTY - HYDRAGRIP SURGICAL - CLAMP INSERTS · Class 2

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00690103044652), received between Jul 12, 2024 and Sep 16, 2026 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 2 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 2 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component7

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 16, 2026Detachment of Device or Device Component

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50793472 ↗
  • MalfunctionSep 12, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED, DURING PROCEDURE, THESE PAIR OF FOGARTY HYDRAJAW INSERTS DETACHED FROM THE CLAMP AND FELL INTO THE PATIENT'S CAVITY (MANUFACTURER'S REFERENCE: (B)(4). THE SAME ISSUE OCCURRED WITH THE REPLACEMENT PAIR (MANUFACTURER'S REFERENCE: (B)(4). THERE WERE NO PATIENT INJURY OR CONSEQUENCES, AND NO ADDITIONAL IMAGING OR INTERVENTION WAS REQUIRED TO RETRIEVE THE INSERTS. THE DEVICES WERE NOT AVAILABLE FOR EVALUATION AS THEY WERE DISCARDED. PATIENT DEMOGRAPHICS UNABLE TO BE OBTAINED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23035773 ↗
  • MalfunctionSep 12, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED, DURING PROCEDURE, THESE PAIR OF FOGARTY HYDRAJAW INSERTS DETACHED FROM THE CLAMP AND FELL INTO THE PATIENT'S CAVITY (MANUFACTURER'S REFERENCE: (B)(4). THE SAME ISSUE OCCURRED WITH THE REPLACEMENT PAIR (MANUFACTURER'S REFERENCE: (B)(4). THERE WERE NO PATIENT INJURY OR CONSEQUENCES, AND NO ADDITIONAL IMAGING OR INTERVENTION WAS REQUIRED TO RETRIEVE THE INSERTS. THE DEVICES WERE NOT AVAILABLE FOR EVALUATION AS THEY WERE DISCARDED. PATIENT DEMOGRAPHICS UNABLE TO BE OBTAINED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23035602 ↗
  • MalfunctionJul 23, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED, DURING USE OF THE HYDRAJAW CLAMP INSERT, IT BECAME DETACHED FROM THE STERILIZED CLAMP AND FELL INTO THE SURGICAL FIELD. THE INSERT WAS RETRIEVED IMMEDIATELY, AND NO ADDITIONAL TREATMENT WAS REQUIRED. THERE WAS NO ALLEGATION OF PATIENT INJURY. THE DEVICE IS NOT AVAILABLE FOR EVALUATION AS IT WAS DISCARDED BY THE HOSPITAL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22577999 ↗
  • MalfunctionJun 26, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING USE OF THE HYDRAJAW CLAMP THERE WAS A GAP BETWEEN THE CLAMP AND HYDRAJAW SIDE OF THE INSERT SINCE THE HYDRAJAW WAS BENT. WHEN THE TISSUE COMES INTO CONTACT WITH THIS GAP, HYDRAJAW SIDE OF A HYDRAJAW CLAMP INSERT GOT DETACHED AND FELL INTO THE SURGICAL FIELD. THERE WAS NO ALLEGATION OF PATIENT INJURY. THE DEVICES IS NOT AVAILABLE FOR EVALUATION AS IT WAS DISCARDED BY THE HOSPITAL.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22341475 ↗
  • MalfunctionJun 19, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING USE OF THE HYDRAJAW CLAMP THERE WAS A GAP BETWEEN THE CLAMP AND HYDRAJAW SIDE OF THE INSERT SINCE THE HYDRAJAW WAS BENT. THIS HYDRAJAW CLAMP INSERT EASILY GOT DETACHED FROM THE CLAMP. THERE WAS NO ALLEGATION OF PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22290018 ↗
  • MalfunctionJul 12, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED, THESE HYDRAJAW CLAMP INSERTS WERE FALLING OFF. THERE WAS NO ALLEGATION OF PATIENT INJURY. THE INSERTS WERE NOT AVAILABLE FOR EVALUATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19728061 ↗

Other CLAMP, VASCULAR devices

All CLAMP, VASCULAR devices →