FREESTYLE® 995MS21Recalls & reported problems
Medtronic, Inc. · VALVE 995MS21 FREESTYLE MS US · Class 3 · Implant
All models of FREESTYLE (33)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00721902316159), received between Apr 4, 2023 and Apr 4, 2023 — classified as 1 death.
The most frequently reported specific device problem is “Calcified” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Calcified1
- Gradient Increase1
Patient problems
- Aortic Valve Insufficiency/ Regurgitation1
- Aortic Valve Stenosis1
- Calcium Deposits/Calcification1
- Heart Failure/Congestive Heart Failure1
- Pulmonary Edema1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathApr 4, 2023Calcified; Gradient Increase; Calcified; Gradient Increase
MEDTRONIC RECEIVED INFORMATION THAT 14 YEARS AND 1 MONTH POST IMPLANT OF THIS 21MM AORTIC BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER VALVE-IN-VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS REPORTED AS SEVERE AORTIC REGURGITATION. IT WAS REPORTED THAT FOUR DAYS LATER, THE PATIENT DIED. THE CAUSE OF DEATH WAS ACUTE ON CHRONIC COMBINED SYSTOLIC AND DIASTOLIC CONGESTIVE HEART FAILURE AND FLASH PULMONARY EDEMA RELATED TO SEVERE VALVULAR HEART DISEASE. IT WAS NOTED THAT THE PATIENT WAS EXPERIENCING SEVERE DEGENERATIVE, SYMPTOMATIC BIOPROSTHETIC AORTIC VALVE STENOSIS WITH A MEAN GRADIENT OF 46MMHG AND FLOW VELOCITY OF 4.3M/S. IT WAS STATED THAT SEVERE AORTIC VALVULAR CALCIFICATION AND PROXIMAL AORTIC ROOT CALCIFICATION WERE OBSERVED ON COMPUTED TOMOGRAPHY ANGIOGRAPHY (CTA).
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Aortic Valve Stenosis; Calcium Deposits/Calcification; Heart Failure/Congestive Heart Failure; Pulmonary Edema
MAUDE report 16675092 ↗
Other heart-valve, non-allograft tissue devices
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue2 deaths404 reports
- INSPIRIS RESILIA AORTIC VALVE 11500AEdwards Lifesciences LLC · Heart-Valve, Non-Allograft Tissue385 reports
- PERCEVAL PVS23Corcym Canada Corp · heart-valve, non-allograft tissue26 deaths337 reports
- MOSAIC® 305C23Medtronic, Inc. · heart-valve, non-allograft tissue327 reports
- MOSAIC® 305C25Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths324 reports
- FREESTYLE® FR995-27Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths318 reports
- FREESTYLE® FR995-29Medtronic, Inc. · heart-valve, non-allograft tissue288 reports
- FREESTYLE® FR99525Medtronic, Inc. · heart-valve, non-allograft tissue2 deaths280 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page