GORE® DrySeal Flex Introducer Sheath GDSF1233Recalls & reported problems

W. L. Gore & Associates, Inc. · DrySeal Hydro Flex Sheath Ao 33cmx12Fr · Class 2

All models of GORE DRYSEAL FLEX Introducer Sheath (29)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
1
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00733132658893), received between Mar 24, 2025 and Sep 30, 2026 — classified as 1 death, 3 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).

1 other recall cover devices cleared under the same FDA submission (K160254); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information2
  • Adverse Event Without Identified Device or Use Problem1
  • Patient Device Interaction Problem1

Patient problems

  • Vascular Dissection3
  • Perforation of Vessels1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Patient Device Interaction Problem

    Patient problems: Perforation of Vessels

    MAUDE report 50941531 ↗
  • DeathOct 15, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE FOLLOWING INFORMATION WAS REPORTED: ON (B)(6) 2025, THE PATIENT UNDERWENT TREATMENT OF AN ABDOMINAL AORTIC ANEURYSM USING A GORE® EXCLUDER® CONFORMABLE AAA ENDOPROSTHESIS AND A GORE®DRYSEAL FLEX INTRODUCER SHEATH. IT WAS REPORTED THE PATIENT¿S ACCESS SITES WERE OUTSIDE OF INSTRUCTIONS FOR USE, THE ILIAC ARTERIES WERE SMALL (MEASUREMENT IS UNAVAILABLE) AND HIGHLY CALCIFIED. WHILE REMOVING THE GORE®DRYSEAL FLEX INTRODUCER SHEATH (DSF1233/(B)(6)) THE ILIAC ARTERY RUPTURED. THE PATIENT CODED, BLOOD LOSS WAS EXCESSIVE (AMOUNT IS UNKNOWN), AND BLOOD PRODUCTS WERE GIVEN DURING CARDIOPULMONARY RESUSCITATION (CPR). THE PATIENT EXPIRED.

    Patient problems: Vascular Dissection

    MAUDE report 23293157 ↗
  • InjuryMar 24, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    ON (B)(6) 2025, PATIENT UNDERWENT AN ENDOVASCULAR PROCEDURE (GORE® EXCLUDER® THORACOABDOMINAL BRANCH ENDOPROSTHESIS) WAS IMPLANTED TO TREAT AN ANEURYSM, UTILIZING TWO 12FR SHEATHS. DURING THIS PROCEDURE, GORE® VIABAHN® VBX BALLOON EXPANDABLE ENDOPROSTHESIS (VBX DEVICE/STENT) WERE IMPLANTED AS BRANCH DEVICES. ON (B)(6) 2025, POST-PROCEDURE, A CT IMAGE REVEALED THE PATIENT DEVELOPED A TYPE 1B DISSECTION AROUND THE LEFT SUBCLAVIAN ARTERY (LSA). IT IS UNKNOWN WHICH 12FR SHEATH WAS USED IN THE LSA. ON THE SAME DAY, A REINTERVENTION SURGERY WAS PERFORMED, IN WHICH A GORE® TAG® THORACIC BRANCH ENDOPROSTHESIS GRAFT DEVICE WAS IMPLANTED IN ZONE 2. THE CT IMAGING ALSO SHOWED THROMBOSED VBX STENTS THAT WERE IMPLANTED IN THE RIGHT RENAL ARTERY (RRA). DISTAL DISSECTION WAS ALSO NOTED FOR THE RRA. ON THE SAME DAY, THE DISSECTION AND THE THROMBOSED RRA STENTS WERE TREATED DURING THE INTERVENTION. THROMBECTOMY WAS DONE, AND A BARE METAL STENT WAS USED FOR 2CM DISTAL EXTENSION. THE IMPLANTED VBX STENTS WERE ALSO RELINED FOR RADIAL STRENGTH WITH IMPLANTATION OF A 7X79 VBX DEVICE. THE 6 X 79 VBX DEVICE WAS IMPLANTED MOST DISTAL IN THE RIGHT RRA. AS REPORTED, THE CAUSE OF THROMBOSIS IS UNKNOWN; HOWEVE

    Patient problems: Vascular Dissection

    MAUDE report 21684774 ↗
  • InjuryMar 24, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    ON (B)(6) 2025, PATIENT UNDERWENT AN ENDOVASCULAR PROCEDURE (GORE® EXCLUDER® THORACOABDOMINAL BRANCH ENDOPROSTHESIS) WAS IMPLANTED TO TREAT AN ANEURYSM, UTILIZING TWO 12FR SHEATHS. DURING THIS PROCEDURE, GORE® VIABAHN® VBX BALLOON EXPANDABLE ENDOPROSTHESIS (VBX DEVICE/STENT) WERE IMPLANTED AS BRANCH DEVICES. ON (B)(6)2025, POST-PROCEDURE, A CT IMAGE REVEALED THE PATIENT DEVELOPED A TYPE 1B DISSECTION AROUND THE LEFT SUBCLAVIAN ARTERY (LSA). IT IS UNKNOWN WHICH 12FR SHEATH WAS USED IN THE LSA. ON THE SAME DAY, A REINTERVENTION SURGERY WAS PERFORMED, IN WHICH A GORE® TAG® THORACIC BRANCH ENDOPROSTHESIS GRAFT DEVICE WAS IMPLANTED IN ZONE 2. THE CT IMAGING ALSO SHOWED THROMBOSED VBX STENTS THAT WERE IMPLANTED IN THE RIGHT RENAL ARTERY (RRA). DISTAL DISSECTION WAS ALSO NOTED FOR THE RRA. ON THE SAME DAY, THE DISSECTION AND THE THROMBOSED RRA STENTS WERE TREATED DURING THE INTERVENTION. THROMBECTOMY WAS DONE, AND A BARE METAL STENT WAS USED FOR 2CM DISTAL EXTENSION. THE IMPLANTED VBX STENTS WERE ALSO RELINED FOR RADIAL STRENGTH WITH IMPLANTATION OF A 7X79 VBX DEVICE. THE 6 X 79 VBX DEVICE WAS IMPLANTED MOST DISTAL IN THE RIGHT RRA. AS REPORTED, THE CAUSE OF THROMBOSIS IS UNKNOWN; HOWEVER

    Patient problems: Vascular Dissection

    MAUDE report 21684725 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K160254. One submission often covers many models, so check the product and lot details in each record.

  • Z-1962-2020 · Nov 18, 2019 · Terminated
    Gore DrySeal Flex Introducer Sheath, Catalog #DSF1433, 33cm 14FR, Sterile. The responsible firm on the label is W. L. Gore & Associates, Inc., Flagstaff, AZ.

Other Introducer, catheter devices