DeRoyal 81-040409Recalls & reported problems
Deroyal Industries, Inc. · Esophageal Stethoscope w/Temperature Sensor · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00749756046008), received between Aug 7, 2024 and Aug 7, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Laceration(s) of Esophagus1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 7, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
PRIOR TO SURGERY VITALS WERE NORMAL. WHEN THE PATIENT ENTERED THE SURGICAL ROOM A DEROYAL ESOPHAGEAL STETHOSCOPE WAS PLACED FOLLOWING ANESTHESIA. SLIGHT RESISTANCE WAS OBSERVED AT THE OROPHARYNX BUT OVERALL, THE INSERTION WAS NOT VERY DIFFICULT. SURG-JELLE WAS USED AS A LUBRICANT TO EASE INSERTION. THE ESOPHAGEAL STETHOSCOPE WAS PLACED TO 30CM FROM THE UPPER LIP AND SECURED ONCE NO STRANGULATION OR BLEEDING ON THE ORAL CAVITY WAS CONFIRMED. AFTER 2HR 25 MINS OF SURGERY THE STETHOSCOPE WAS REMOVED, AND RED BLOOD WAS OBSERVED ON THE TIP OF THE STETHOSCOPE. NO BLOOD WAS FOUND DURING ENDOTRACHEAL SUCTION. A SMALL AMOUNT OF BLOOD WAS FOUND DURING INTRAORAL SUCTION. THERE WAS NO VISIBLE BLOOD ON THE TRACHEAL TUBE ONCE REMOVED. DURING POST OP THE PATIENT INTERMITTENTLY COUGHED AN INSIGNIFICANT AMOUNT OF BLOOD WHICH DECREASED OVER TIME. THE PATIENT WAS RELEASED TO THE GENERAL WARD BUT CONTINUED TO HAVE UNCLEAR COMPLAINTS THE PATIENT BEGAN COUGHING OUT BLOODY SPUTUM AND HIS BP DROPPED. $ HOURS AND 30 MINS POST OP A L TUBE WAS INSERTED, AND IRRIGATION PRESENTED BLOODY. THE LARYNGOSCOPIC EXAMINATION LED TO THE IDENTIFICATION OF A LINEAR LACERATION (1CM WIDE BY 1-2 MM DEEP). THE LACERATION WAS
Patient problems: Laceration(s) of Esophagus
MAUDE report 19929635 ↗
Other STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS devices
- Mon-a-Therm 90042Covidien LP · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS1 recall0 reports
- DeRoyal 81-040418Deroyal Industries, Inc. · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS3 reports
- DeRoyal 81-040412Deroyal Industries, Inc. · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS3 reports
- Medline DYNJAER4009Medline Industries, Inc. · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS2 reports
- DeRoyal 81-050409Deroyal Industries, Inc. · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS1 report
- Mon-a-Therm 90041Covidien LP · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS1 report
- DeRoyal 81-050418Deroyal Industries, Inc. · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS1 report
- Mon-a-Therm 90049Covidien LP · STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS1 report
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.