KYPHON LATITUDE II Curette A11BRecalls & reported problems
Medtronic Sofamor Danek, Inc. · CURETTE A11B KYPHX CURETTE II T-TIP · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00763000031909), received between Oct 27, 2019 and May 6, 2022 — classified as 4 malfunctions.
The most frequently reported specific device problem is “Break” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break3
- Mechanical Problem2
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 6, 2022Break; Break
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A CURETTE USED IN BKP FOR VERTE BRAL FRACTURE. PREOPERATIVE DIAGNOSIS OF THIS SURGERY WAS PRIMARY OSTEOPOROSIS. IT WAS REPORTED THAT IT BROKE JUST BY GRIPPING THE CURETTE TWICE DURING THE PROCEDURE. THERE WAS NO PATIENT SYMPTOM REPORTED. THE PROCEDURE WAS COMPLETED USING A NEW PRODUCT. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14302384 ↗MalfunctionDec 28, 2021Mechanical Problem; Mechanical Jam; Mechanical Problem; Mechanical Jam
MDR DECISION CORRECTED TO NOT REPORTABLE. NO ADDITIONAL SUPPLEMENTALS REQUIRED UNLESS ADDITIONAL INFORMATION RECEIVED INDICATES REPORTABLE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13091784 ↗MalfunctionNov 29, 2021Break; Break
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER (HCP) VIA A MEDTRONIC REPRESENTATIVE REGARDING A PATIENT IMPLANTED WITH A SPINAL PRODUCT USING A CURETTE IN A BKP FOR A COMPRESSION FRACTURE DUE TO PRIMARY OSTEOPOROSIS. IT WAS REPORTED THAT THE CURETTE HANDLE AND TIP NO LONGER INTERLOCK. THE TIP BECAME IMMOBILE FROM THE MIDDLE. WHEN CHECKING THE CURETTE, IT SEEMED THAT THE PRODUCT WAS SEPARATED AT THE NOTCH PART. IT IS UNKNOWN IF THERE WERE PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THE EVENT. NO FURTHER COMPLICATIONS WERE REPORTED/ ANTICIPATED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12880405 ↗MalfunctionOct 27, 2019Break; Mechanical Problem; Break; Mechanical Problem
PRE-OPERATIVE DIAGNOSIS: PRIMARY OSTEOPOROSIS TYPE OF FRACTURE: COMPRESSION FRACTURE IT WAS REPORTED THAT INTRA-OP, AFTER THE CURETTE WAS INSERTED INTO THE VERTEBRAL BODY, THE ANGLE DID NOT CHANGE EVEN WHEN THE LEVER WAS GRASPED. THE CURETTE WAS BEING USED IN ACCORDANCE WITH THE SURGICAL TECHNIQUE. THE TIP OF THE CURETTE DID NOT MOVE EVEN WHEN THE SURGEON WAS CHECKING OUTSIDE THE PATIENT¿S BODY. HENCE, ANOTHER CURETTE WAS OPENED AND WAS USED TO COMPLETE THE PROCEDURE SUCCESSFULLY. THERE WAS A DELAY OF LESS THAN 60 MINUTES IN THE OVERALL PROCEDURE DUE TO THIS EVENT. NO PATIENT COMPLICATIONS WERE REPORTED. WHEN THE CURETTE WAS CHECKED, IT WAS FOUND THAT A PART OF THE CURETTE HAD SEPARATED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9243341 ↗
Other ORTHOPEDIC MANUAL SURGICAL INSTRUMENT devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page