InterStim™ Micro SureScan™ 97810Recalls & reported problems
Medtronic, Inc. · INS 97810 ISTM MICRO SSMRI RC EMAN US · Class 3 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This InterStim Micro neurostimulator from Medtronic is an implanted device used for incontinence. Its 2,764 reports mostly describe charging trouble, battery problems, and chargers or communicators that cannot find the implant. The reports include no deaths and 806 injuries, and some mention electric shocks or pain. Reports in the last 12 months (269) are well below the previous 12 months (466). No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 2,762
- Deaths reported
- 0
- Injuries reported
- 807
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2,762 adverse event reports that list this exact device (DI 00763000203849), received between Sep 4, 2020 and Sep 30, 2026 — classified as 807 injuries, 1,955 malfunctions.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (938 reports).
7 other recalls cover devices cleared under the same FDA submission (P080025, P970004); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information938
- Charging Problem739
- Battery Problem659
- Communication or Transmission Problem596
- Failure to Deliver Energy443
- Inappropriate/Inadequate Shock/Stimulation334
- Migration or Expulsion of Device317
- Failure to Interrogate279
Patient problems
- No Clinical Signs, Symptoms or Conditions1,414
- Insufficient Information632
- Pain354
- Electric Shock350
- Incontinence244
- Discomfort195
- Urinary Frequency / Polyuria121
- Undesired Nerve Stimulation113
Recent adverse event reports
The 25 most recent of 2,762 reports, in the reporter's own words as published by the FDA.
InjurySep 30, 2026Inappropriate/Inadequate Shock/Stimulation
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for gastrointestinal/pelvic floor therapy, urinary dysfunction/sacral nerve stim and bladder issues. It was reported that patient noticed a couple of months ago shocking sensation when they use the wireless recharger and the communicator. The pt mentioned is doesn't happen often every time but for about 3 times now when they use the external device the issue have occured. The agent reviewed general therapy and device-use information and advised the pt to turn their INS off if the shocking continued and discontinue the use of the external devices. The agent also redirected th ept to their HCP to have their INS checked.
Patient problems: Electric Shock
MAUDE report 50946853 ↗InjurySep 29, 2026Failure to Interrogate; Malposition of Device; Communication or Transmission Problem; Insufficient Device Problem Information
Information was received from a healthcare provider (HCP) and a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim and gastrointestinal/ pelvic floor. It was reported that they were trying to put the device into MRI mode, but they were getting "Device not responding". The caller stated that the patient indicated they hadn't used the implant or external equipment for a long time. The agent walked the caller through repositioning the communicator but they continued to receive "Device not responding." The agent walked the caller through using the recharger and they described seeing open loop charging screen with the battery in the red and Antenna Locate numbers. The caller repositioned the recharger multiple times and the hi ghest value they were able to obtain was 15 and noted recharger was warm. While working with the recharger, the agent heard the patient in the background say "it hurts." The agent asked if the caller could palpate the implant and they were not able to feel it. The agent reviewed that the caller could continue to reposition the recharger to try and get higher numbers to see if they could obtain better conne
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50937696 ↗MalfunctionSep 29, 2026Failure to Power Up; Battery Problem; Charging Problem; Insufficient Device Problem Information
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50934166 ↗MalfunctionSep 29, 2026Display or Visual Feedback Problem; Insufficient Device Problem Information
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50933466 ↗MalfunctionSep 28, 2026Battery Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50925362 ↗InjurySep 28, 2026Migration or Expulsion of Device; Unintended Collision; Energy Output Problem; Insufficient Device Problem Information
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim, gastrointestinal/pelvic floor. It was reported that the reason for the call was the patient reported they had a fall on the 14th and slipped or fell off their porch onto cement and hit their left hip to their mid back near their stimulator. They started having pain in the stimulator area so they went to the ER on the 18th and they did x-rays and said everything there checked out fine but patient was still feeling stiff. The patient did not know if it caused any device damage or migration but suspected this might be the case because the patient was in pain all night and was up half the night on a heating pad because it was the only thing that would relieve the pain. They were feeling burning pain from one hip to the other. The pain improved and they were able to sleep once turning the stimulator off but they were still feeling a sensation. The patient had an appointment with their new managing physician on October 21st at 11am in Midland, MI. The patient will leave therapy off until that time. Reviewed general risks of falls and notified fiel
Patient problems: Burning Sensation; Muscular Rigidity; Pain; Sleep Dysfunction
MAUDE report 50913942 ↗MalfunctionSep 28, 2026Battery Problem
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for urinary/bowel dysfunction, fecal incontinence. It was reported that the reason for the call was the patient said they changed the time on the handset from New Zealand time back to the US time and when they opened the Micro My Therapy app to check the battery status they saw a message that said data has been lost contact your physician. The patient said this was what happened before (see (b)(6)). The patient was redirected to their healthcare provider to further address the issue. The patient said they didn't have a doctor they were currently working with. The patient said when this happened in the past they spoke with someone over the phone who gave them a password to get into the app where they could see all their programs and they were able to clear this message and get therapy turned back on. The patient said they would like that to be done again. Patient services reviewed the patient app vs clinician app. The patient asked for an exception and to speak with a supervisor. The agent reviewed the password could not be given to patients. The patient said they were a retired Oncol
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50913858 ↗InjurySep 21, 2026Battery Problem
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim and gastrointestinal/pelvic floor. It was reported that their INS doesn't stay charged for a week, and doesn't work, meaning they were not getting therapeutic effect and having urinary incontinence no matter how they program it. The symptoms have been getting worse the last 3 months and patient has tried 3 different programs. The patient services (PS) reviewed handset charging frequency has no impact on therapeutic effect and INS charging frequency varies depending on device programming. The patient indicated their primary concern was that the therapy was not helping with their urinary control and they could not make it to the bathroom without peeing through the house. The patient reported they have had a few falls. They spoke with a physician's assistant at doctor's (dr) office and they directed the patient to contact manufacturer. Patient did not know dr's first name. Reviewed general theory and use of programs. Reviewed possible risks of falls and recommended patient work with managing physician's office to determine the cause of the loss
Patient problems: Urinary Incontinence
MAUDE report 50842413 ↗MalfunctionSep 17, 2026Battery Problem
Additional information was received from the patient. They reported that they received a new device on (B)(6) 2026 that they never have to charge.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50810566 ↗InjurySep 16, 2026Intermittent Continuity; Insufficient Device Problem Information
Information was received from a patient (pt) who was implanted with an implantable neurostimulator (INS) for gastrointestinal/ pelvic floor. It was reported that within the last 1- days they had cramping in their stomach and thought it was due to amoxicillin they took for a dental procedure but now they did not know because starting 3 days ago, they noticed blood where their anus was and blood on their tissue when they urinated. Pt also noticed feeling intermittent throbbing in the front, between their legs and the front labia, not their anus area which had woken them up in the middle of the night and caused them to leave church. Pt said the activity of the battery had become erratic and shifted from their anus to between their legs and it was throbbing very hard. Pt said they called the doctor's office yesterday and was told they could turn it off so they did but the throbbing did not stop and after 3 hours they turned it back on, they decreased it from 1.7 or 1.9 down to 0.5 and that was much more manageable. Pt said the doctor's office told them their battery was not acting properly and the patient should coordinate a manufacturer's representative (rep) appointment at the office
Patient problems: Abdominal Cramps; Hematuria; Hemorrhage/Blood Loss/Bleeding; Pain; Sleep Dysfunction
MAUDE report 50794719 ↗MalfunctionSep 7, 2026Unstable; Charging Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50655610 ↗MalfunctionSep 4, 2026Malposition of Device
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50610442 ↗MalfunctionSep 3, 2026Charging Problem; Insufficient Device Problem Information
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for gastrointestinal/pelvic floor therapy. It was reported that they are having trouble charging the recharger. All three lights are blinking green. It was noted in the repair request that there was scrolling lights on the recharger. The issue started this week. Walked caller through resetting the recharging device. The troubleshooting steps that were taken on the call did not resolve the issue. Agent asked if they store the recharger in the dock when not using it. They said they try to. Sent request to repair to replace the Wireless Recharger.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50579111 ↗InjurySep 2, 2026Charging Problem; Insufficient Device Problem Information
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for gastrointestinal/pelvic floor, urinary dysfunction/sacral nerve stim. It was reported that the patient reported for the past 5 months they felt uncomfortable since the INS was not working because their wireless recharger was not charging and was not able to recharge their INS. The patient mentioned they saw the scrolling battery lights on the recharger and it was not emitting any tones. The patient added their doctor redirected them to call the manufacturer for assistance. The agent reviewed how to attempt a hard reset, but did not resolved the issue. The agent sent repair request. On 2026-Jul-13 additional information was received from the patient. The patient stated that the replacement recharger resolved their issues.
Patient problems: Discomfort; No Clinical Signs, Symptoms or Conditions
MAUDE report 50566206 ↗InjurySep 2, 2026Failure to Deliver Energy; Electromagnetic Compatibility Problem
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for Gastrointestinal/Pelvic Floor and Urinary Dysfunction/Sacral Nerve Stim. It was reported that for the last 2-3 months they experienced a loss of therapeutic benefit. The patient said they were bed wetting and going through at least 3 nighttime pads because they couldn't hold it anymore. The patient mentioned they were taking a medication as well, but that wasn't helping either. A couple of days ago the patient increased the amplitude on program 1 from 1.5 mA to 1.6 mA, but they didn't feel any stimulation. The patient mentioned that they just had hip surgery and were numbed "down there," so they wondered if that was why they couldn't feel stimulation. Agent reviewed stimulation expectations and considerations for therapy optimization. The patient decided to increase the amplitude and confirmed they felt comfortable stimulation. The patient will maintain stimulation level and continue to monitor symptoms.
Patient problems: Incontinence; Urinary Incontinence
MAUDE report 50558998 ↗MalfunctionSep 1, 2026Battery Problem; Charging Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50544727 ↗InjurySep 1, 2026Charging Problem; Communication or Transmission Problem
Additional information was received from a manufacturer representative (rep). The rep reported that they did not ask the customer to return the patient's previous INS as they were not aware of this situation. Device was discarded at time of replacement per implanting Physician's direction.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50543123 ↗InjurySep 1, 2026Insufficient Device Problem Information; Data Problem
Information was received from a patient with an implanted neurostimulator (INS) for urinary dysfunction/sacral nerve stim and gastrointestinal/pelvic floor therapy. It was reported that the reason for the call was patient reported therapy issue. The patient stated that they had a fall in the driveway after receiving the implant in 2020, and the INS had been working well until this year. The patient mentioned that the communicator battery would drop over 2 to 3 hours. The patient confirmed that they charged the INS to 100% a day before. The patient confirmed that they had not consulted their HCP and stated they were making adjustments themselves with the help of their daughter, who is a nurse. The agent sent a replacement request to repair for the communicator and transferred the call to HCIT to address the handset issue. The patient was redirected to their healthcare provider to further address the issue. Upon further review, the patient mentioned that they do not know if the INS was getting weak, gradually going down, or shutting off and causing them to urinate all over themselves. The patient stated that when they connected to the INS, they saw that they were in Program 6 at 0.6
Patient problems: Incontinence; Insufficient Information
MAUDE report 50535903 ↗MalfunctionSep 1, 2026Failure to Deliver Energy
Information was received from a patient with an implanted neurostimulator (INS) for urinary dysfunction/sacral nerve stim and gastrointestinal/pelvic floor therapy. It was reported that they have been experiencing when the handset or the communicator goes dead the therapy shuts off. Agent explained that the therapy shouldn't shut off because the handset or communicator goes dead. Patient said they have been getting a message indicating the therapy was off, but they don't remember the message that they have received on the handset. The issue with the therapy shutting off they have been really experiencing in the last month. The patient was redirected to their healthcare provider to further address the issue.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50535882 ↗InjuryAug 28, 2026Energy Output Problem; Therapeutic or Diagnostic Output Failure; Insufficient Device Problem Information
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for unknown indications for use. It was reported that ever since they got their new wireless recharger, they unable to further increase their stimulation in their current program. Patient stated that every time they go to a certain level off stimulation on their current program, they were seeing the OOR message. Patient added that the OOR message was only showing on their current program and not on the other programs. Agent reviewed information and redirected the patient to their HCP to further address the issue. Patient stated that they currently don't have a HCP and refused when agent offered to send physician listing indicating they would contact the manufacturing representative (rep) to set up an appointment. On 2026-Aug-27 additional information was received from the patient. The patient stated that they received a new implant couple of weeks ago because the previous implant failed.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50497292 ↗InjuryAug 21, 2026Break; High impedance; Energy Output Problem; Therapeutic or Diagnostic Output Failure; Insufficient Device Problem Information
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for urinary/bowel dysfunction, urge incontinence. It was reported that the reason for call was patient reported when they tried to increase stimulation on any program they were not able to due to getting system is operating at maximum settings message. Patient reported therapy was at 0.5 and will not go any higher. Patient stated they have 7 programs and they cannot increase on most programs beyond 0.3. Patient mentioned they had a suspicion this might be a wire issue, but stated they were hoping that was not the case. Reviewed meaning of message and redirected patient to healthcare provider to further address the issue. Patient reported they got checked out on the 18th and they went into their bladder with a scope to check patient out and patient reported over the weekend they could not pass any urine so they ended up in the hospital and they had to \"bag\" patient so right now they have a bag hanging off the side of them with a catheter because they couldn't urinate. Patient checked to see if this unit was working when they got home because they thought it was working but reported
Patient problems: Urinary Retention
MAUDE report 50380528 ↗InjuryAug 20, 2026Insufficient Device Problem Information
Information was received from a healthcare provider regarding a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim and gastrointestinal/pelvic floor. It was reported that the patient's (pt) system was explanted today due to a malfunction. When asked, the caller had no further details about the malfunction or when it started. They also did not know the name of the healthcare provider (HCP). The agent reviewed pertinent disposal information.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50357771 ↗InjuryAug 20, 2026Adverse Event Without Identified Device or Use Problem
Information was received from a friend/family member regarding a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim;gastrointestinal/pelvic floor It was reported that the INS is no longer working. Caller stated that the patient is in a nursing home, and is totally incontinent. Caller added that the INS was not helping at all, and at the very best they had 30-40% symptom improvement. 's, and the INS is not making any change anymore, and added that the leaking is just so bad the device is no longer working and is no longer needed because he is totally incontinent The agent documented reported events. Additional information was received from the patient representative. They reported that they had contacted their doctor about this on (b)(6) 2026. They stated that the device not working was describing that the implanted device did not seem to be helping with urinary incontinence. The unit was charged and appeared ok, put Parkinson's was worse. They stated that it was not caused by normal battery depletion. They stated that advancing Parkinson's disease was the likely cause of the device not working. They stated that they were s
Patient problems: Urinary Incontinence
MAUDE report 50351882 ↗InjuryAug 7, 2026Failure to Interrogate; Battery Problem; Charging Problem; Communication or Transmission Problem
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim, gastrointestinal/pelvic floor. It was reported that the patient reported that they were having an issue with their handset. The patient stated that the handset screen displays the handset battery level as 100%, but they couldn't get it to show anything else and they can see horizontal and vertical lines on the screen. As a result, the patient was unable to connect to the INS as needed. The patient thought the issue might have been the charging cable for the handset because the handset wouldn't charge at one point. The patient called their doctor's office, and they called a manufacturer rep. The rep called the patient and advised the patient to call Patient Services for assistance. The patient denied dropping the handset, but they thought the screen might have gotten cracked somehow. The patient was driving at the time of the call, so they could not confirm if the screen was actually cracked. The patient said they would call back when they weren't driving to provide more detail. The patient mentioned that their INS battery was dead because it
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50176872 ↗InjuryAug 5, 2026Failure to Power Up; Charging Problem; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
Information was received from a patient who was implanted with an implantable neurostimulator (INS) for urinary dysfunction/sacral nerve stim, gastrointestinal/pelvic floor. It was reported that the reason for the call was the recharger will not take a charge. Patient states this issue has been for about 2 weeks and patient was having trouble urinating . Patient states the recharger has 3 blinking green lights but when they go to turn it on, nothing happens, it does not power on and it does not start beeping. . Agent had patient hold down the power button and try a different outlet . The issue was not resolved through troubleshooting. An email was sent to the repair department to replace the device. On 2026-Jun-08 additional information was received from the patient. Patient called back requesting assistance with pairing the recharger. Agent walked caller through successful pairing. Agent reviewed they need to charge INS and then use the therapy app to turn therapy back on.
Patient problems: Dysuria; No Clinical Signs, Symptoms or Conditions
MAUDE report 50144633 ↗
FDA clearance and classification
Approved through premarket approval (PMA) P080025 on Mar 14, 2011. Submitted by Medtronic Neuromodulation as “Medtronic Interstim Sacral Nerve Stimulation Therapy System”. The FDA review took 899 days. The FDA has since approved 350 supplements (changes to the device or its labeling), most recently on Oct 29, 2026. FDA record ↗
Approved through premarket approval (PMA) P970004 on Sep 29, 1997. Submitted by Medtronic Neuromodulation as “Medtronic Interstim Therapy System For Urinary Control”. The FDA review took 242 days. The FDA has since approved 449 supplements (changes to the device or its labeling), most recently on Oct 29, 2026. FDA record ↗
The FDA regulates product code EZW (stimulator, electrical, implantable, for incontinence) under 21 CFR 876.5270 as a Class III device. 21 CFR 876.5270 ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under P080025, P970004. One submission often covers many models, so check the product and lot details in each record.
- Z-1704-2025 · Apr 3, 2025 · Open, ClassifiedEnhanced Verify Evaluation Handset (CFN HH90130FA)
- Z-0372-2025 · Sep 18, 2024 · Open, ClassifiedMedtronic Recharger Kits, RS6230, RS7230, and RS5220A, containing components WR9230 and WR9220A Recharger for rechargeable implantable neurostimulators. The Rechargers are used wi
- Z-2365-2023 · Jul 6, 2023 · Open, ClassifiedMedtronic InterStim Ground Pad REF 041826
- Z-0998-2022 · Feb 28, 2022 · TerminatedMEDTRONIC INTERSTIM THERAPY SYSTEM FOR URINARY CONTROL, which includes the following: a) Handset with Communicator, Model Numbers: 1) TH90Q01, 2) TH90QFA, 3) TH90PFA, 4) TH90GFA,
- Z-1147-2015 · Jan 9, 2015 · TerminatedThe Medtronic, Quadripolar ITREL 3 IPG, Model 7425, is a multiprogrammable device designed for use in the Stimulation of the Central Nervous System, Peripheral Nervous System, or m
- Z-0040-2008 · Jun 25, 2007 · TerminatedMedtronic InterStim INS (Model 3023) with N'Vision Inter Stim-B software supplied on the Model 8870 Version MMB_01/NNB_01 with N'Vision Clinician Programmer Model 8840 or InterStim
- Z-0037-2008 · Jun 25, 2007 · TerminatedMedtronic InterStim II INS Model 3058 with N'Vision InterStim-B Software supplied on the Model 8870 Version MMB_01/NNB_01 N'Vision with a Clinic an Programmer Model 8840. Implanta
Common questions about the InterStim™ Micro SureScan™ 97810
Has the InterStim™ Micro SureScan™ 97810 been recalled?
No FDA recall record in our data names this exact device identifier (DI 00763000203849), based on the FDA recall file dated Nov 27, 2026. However, 7 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the InterStim™ Micro SureScan™ 97810?
The FDA's MAUDE database lists 2,762 adverse event reports for this device, received between Sep 4, 2020 and Sep 30, 2026. In those reports, the most common specific device problems are “Charging Problem” (739), “Battery Problem” (659) and “Communication or Transmission Problem” (596); the most common patient problems are “Pain” (354), “Electric Shock” (350) and “Incontinence” (244). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the InterStim™ Micro SureScan™ 97810?
None of the reports are classified as deaths, 807 as injuries and 1,955 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the InterStim™ Micro SureScan™ 97810 FDA approved?
It was approved through premarket approval (PMA) P970004 on Sep 29, 1997; its record lists 2 FDA submissions in total.
Is the InterStim™ Micro SureScan™ 97810 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the InterStim™ Micro SureScan™ 97810, and is it still sold?
The FDA's device database lists Medtronic, Inc. as the company responsible for it (brand InterStim™ Micro SureScan™, model 97810). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Stimulator, electrical, implantable, for incontinence devices
- INTERSTIM® 3058Medtronic, Inc. · Stimulator, electrical, implantable, for incontinence6 deaths23,076 reports
- InterStim™ X 97800Medtronic, Inc. · Stimulator, electrical, implantable, for incontinence1,840 reports
- Axonics 4101Axonics Modulation Technologies, Inc. · Stimulator, Electrical, Implantable, For Incontinence1 death818 reports
- INTERSTIM® 3058Medtronic, Inc. · Stimulator, electrical, implantable, for incontinence818 reports
- Axonics 1101Axonics Modulation Technologies, Inc. · Stimulator, Electrical, Implantable, For Incontinence1 death399 reports
- Axonics 5101Axonics Modulation Technologies, Inc. · Stimulator, Electrical, Implantable, For Incontinence162 reports
- INTERSTIM® 3023Medtronic, Inc. · Stimulator, electrical, implantable, for incontinence1 death147 reports
- INTERSTIM® 3023Medtronic, Inc. · Stimulator, electrical, implantable, for incontinence110 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page