Axonics Modulation Technologies, Inc. · Neurostimulator · Class 3 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Axonics neurostimulator is an implanted nerve stimulator used to treat incontinence. Its 825 reports include 1 death and 802 injuries. Many describe pain and discomfort at the implant site, and some describe infections, skin erosion, or the device moving, often leading to surgery. Reports fell to 272 in the last 12 months, down from 416 in the 12 months before. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
818
Deaths reported
1
Injuries reported
795
Recalls naming it
0

Summary

The FDA's MAUDE database contains 818 adverse event reports that list this exact device (DI 10810005340455), received between Jun 29, 2022 and Sep 30, 2026 — classified as 1 death, 795 injuries, 22 malfunctions.

The most frequently reported specific device problem is “Migration” (114 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 8 reportsJan 2024: 1 reportsFeb 2024: 12 reportsMar 2024: 11 reportsApr 2024: 6 reportsMay 2024: 6 reportsJun 2024: 9 reportsJul 2024: 9 reportsAug 2024: 5 reportsSep 2024: 16 reportsOct 2024: 11 reportsNov 2024: 12 reportsDec 2024: 8 reportsJan 2025: 19 reportsFeb 2025: 8 reportsMar 2025: 10 reportsApr 2025: 9 reportsMay 2025: 29 reportsJun 2025: 53 reportsJul 2025: 52 reportsAug 2025: 52 reportsSep 2025: 83 reportsOct 2025: 81 reportsNov 2025: 52 reportsDec 2025: 46 reportsJan 2026: 25 reportsFeb 2026: 33 reportsMar 2026: 21 reportsApr 2026: 4 reportsMay 2026: 12 reportsJun 2026: 12 reportsJul 2026: 22 reportsAug 2026: 15 reportsSep 2026: 23 reportsOct 2026: 0 reportsNov 2026: 0 reports20242025202683
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem612
  • Migration114
  • Lack of Effect45
  • High impedance32
  • Communication or Transmission Problem27
  • Impedance Problem11
  • Nonstandard Device8
  • Fracture6

Patient problems

  • Pain185
  • Discomfort162
  • Unspecified Infection152
  • Incontinence149
  • Implant Pain119
  • No Clinical Signs, Symptoms or Conditions117
  • Urinary Tract Infection87
  • Undesired Nerve Stimulation64

Recent adverse event reports

The 25 most recent of 818 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Fracture; High impedance; Communication or Transmission Problem

    It was reported that the patient with this Neurostimulator (INS) had a solid red light on their remote control. The Therapy Support Specialist (TSS) tried assist in changing programs, but the red light was on both programs. Additional information reported when the patient was seen in-office, it was discovered the patient had high impedance. Then the patient had surgery to replace their Tined Lead and INS. During the revision, the physician disconnected the INS from the lead and had the lead tested and yellow impedance was present. Then the physician reinserted the lead into the INS and there was red impedance. The physician requested a new INS, but red impedances were still noted when connected to the lead. An x-ray image showed the lead was fractured leading to the physician to replace the lead on the contralateral side. There was no patient complications reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50951311 ↗
  • InjurySep 30, 2026Migration

    It was reported that the patient with this implantable Neurostimulator fell on their back about a month ago. The patient began to experience constant pain at the implant site about two weeks ago and worsens with activity; therefore, stimulation was turned off. It was observed that the Neurostimulator easily moves within the pocket site. Impedances were also checked and found within normal ranges on all electrodes. Patient stated in preop that she still has some urgency. The patient had a pocket revision, and the physician was able to palpate the INS superficially under the skin and shifted it vertically in the pocket, so that it is not protruding or tilted at all. The physician kept the original INS implanted in the same incision site but buried the INS deeper under the skin. The INS and Lead were both in good condition per the physician and did not need replacement at time of revision. The patient's system was reprogrammed and placed on a comfortable setting. There were no additional patient complications reported.

    Patient problems: Discomfort; Implant Pain; Micturition Urgency

    MAUDE report 50951302 ↗
  • InjurySep 30, 2026Communication or Transmission Problem; Power Problem

    It was reported that the patient with this Recharge-Free SNM IPG noticed a red light on their remote and could not adjust their stimulation. The red light could not be cleared. The patient later underwent a revision. There were no reported patient complications.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50950616 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with this Neurostimulator (INS) requested a device removal. The patient did not specify why they wanted their device explanted. The procedure was completed as planned with no patient complications reported.

    Patient problems: Micturition Urgency; Urinary Frequency / Polyuria

    MAUDE report 50941050 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with the neurostimulator underwent tined lead and INS revision due to pocket site pain and sensation in the leg. An x-ray was taken to see if the battery or lead have moved. Both the tined lead and the INS were revised from the left to the right. The tined lead was replaced and the INS was moved.

    Patient problems: Discomfort; Pain

    MAUDE report 50934074 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with the neurostimulator underwent a revision due to the device not working after an unrelated surgery.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50933966 ↗
  • InjurySep 23, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with this Implantable Neurostimulator (INS) was scheduled for a revision procedure involving the lead and INS pocket due to discomfort and intermittent pain at the lead insertion site and implant site. It was reported that the patient could feel the implanted components, which rubbed against surrounding tissue when sitting in certain positions. The patient denied any trauma or falls near the affected area. The physician's plan was to retain the existing lead and INS and reposition them deeper beneath the skin during the revision procedure. Additional information received indicated that no device related issue was identified. The patient underwent the revision procedure as scheduled. During the procedure, the INS was relocated to the patient's left side, and the existing lead was retained and tunneled to the new implant location. No further patient complications were reported.

    Patient problems: Discomfort; Pain

    MAUDE report 50862961 ↗
  • InjurySep 18, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG experienced device protrusion at the implant site. A full system explant was performed. The physician reported that there was no evidence of infection and no signs of device damage at the time of explantation. No further patient complications were reported.

    Patient problems: Wound Dehiscence

    MAUDE report 50823953 ↗
  • InjurySep 18, 2026Communication or Transmission Problem

    It was reported that the patient with this Recharge-Free SNM IPG noticed a yellow light on their remote and could not feel stimulation. Upon assessment with their physician, their incision site was drained of fluid and the patient was able to connect and reset their device, then felt stimulation accordingly. The patient later tested positive for a STAPH infection. The patient was explanted.

    Patient problems: Unspecified Infection

    MAUDE report 50822421 ↗
  • InjurySep 18, 2026Migration

    It was reported that the patient with this Neurostimulator (INS) lost 30 pounds and noticed their INS was protruding and caused pain. An x-ray showed that it twisted in the pocket. Due to the weight loss, the patient wanted to switch to the smaller rechargeable INS. The patient had surgery to switch their non-rechargeable INS for the smaller rechargeable version. The Tined Lead stayed in place and was not revised. The patient is doing well.

    Patient problems: Pain; Weight Changes

    MAUDE report 50817286 ↗
  • InjurySep 17, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG experienced pain and discomfort at the incision site. Stimulation had been turned off to assess whether the device was contributing to the symptoms. The patient reported having X rays performed; however, results were not available to the current physician at the time of evaluation. Clinical evaluation of the implant site showed tenderness without redness or swelling. A topical analgesic patch was used, after which the discomfort resolved. Additional information received indicated that troubleshooting included turning stimulation off for approximately two weeks; however, pain persisted. Impedance testing was performed and results were reported as normal. The physician reported that no abnormalities were identified during physical examination and planned to review the X rays at the time of explantation. Follow up information confirmed that the patient underwent explantation. The patient was reported to be stable. No further patient complications were reported.

    Patient problems: Discomfort; Inappropriate Device Stimulation of Tissue; Pain

    MAUDE report 50812199 ↗
  • InjurySep 15, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG observed leakage at the incision site. Subsequently, the physician explanted the device. No further patient complications were reported as a result of this event.

    Patient problems: Fluid Discharge; Purulent Discharge; Unspecified Infection

    MAUDE report 50779520 ↗
  • InjurySep 15, 2026Migration

    It was reported that the patient with this Neurostimulator (INS) was kicked in their pocket site by their son when lying next to them. Afterwards, the INS moved in the pocket, causing the patient pain. This did not cause any change in bladder symptoms. The patient had surgery to move the INS to the other side of their body. During the post-revision follow-up call, patient stated they are doing well.

    Patient problems: Discomfort; Pain

    MAUDE report 50777145 ↗
  • InjurySep 9, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient was implanted with a Recharge-Free SNM IPG, but their incision was not healing, so a battery swap was performed as the previous battery site was open and exposed. X-rays were taken to show the integrity of the lead and their motor responses were tested and all were under 2 amps. The device was explanted entirely on (b)(6) 2025 because their incision was not healing. The patient stated that they felt fine but was frustrated because their trial worked well. The patient was on numerous doses of antibiotics.

    Patient problems: Impaired Healing; Pocket Erosion; Unspecified Kidney or Urinary Problem; Wound Dehiscence

    MAUDE report 50699222 ↗
  • InjurySep 9, 2026Adverse Event Without Identified Device or Use Problem

    It was reported the patient said they want their device out due to discomfort. The patient had a two-week stimulation holiday to rule out the stimulation as the cause of the discomfort and reported doing well afterwards. The patient said they have not had as many accidents as before, and their symptoms were doing well despite the stimulation being off. The local care team member advised the patient they contact the affiliated urologist to discuss the explant. The patient denied they told the local care team member the device was uncomfortable, despite it being noted that they reported discomfort. The patient said they were doing okay, but wanted their device explanted due to it not working for them and not interested in turning their device back on to try the therapy again. The patient had surgery to explant their Neurostimulator and Tined Lead. The patient is doing well. They stated they had some bruising related to the surgery but denied any pain. It was recommended to the patient that they reach out to the physician if they have any medical-related questions or concerns moving forward.

    Patient problems: Discomfort; Pain

    MAUDE report 50698800 ↗
  • InjurySep 8, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG noted their stitches were bothering them post implant. A non-implanting physician removed these stiches from the incision site and replaced with new sutures. The patient later returned to the office as their incision site had opened 1 cm. The site was redressed and the patient was given antibiotics. After meeting with their implanting physician, it was noted that the incision site was healing properly and did not open any further. The patient was advised to continue the antibiotics and follow up in one week. There was no additional patient complications reported.

    Patient problems: Wound Dehiscence

    MAUDE report 50679297 ↗
  • InjurySep 8, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG had their device explanted due to pain and discomfort at their implant site that was exacerbated by their spinal arthritis. Their surgeon explanted the patient's IPG from the right pocket and implanted a smaller rechargeable SNM IPG in the left pocket. The procedure was completed and the patient is recovering. There was no additional patient complications reported.

    Patient problems: Discomfort; Implant Pain

    MAUDE report 50678890 ↗
  • InjurySep 8, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with this Neurostimulator (INS) experienced pocket pain. The physician planned to use the rechargeable INS since it is smaller for the body habitus of the patient and place it on the opposite side of the body. Additional information reported that the patient swapped their INS for the rechargeable version. The patient is doing well post procedure with no additional patient complications.

    Patient problems: Implant Pain

    MAUDE report 50676594 ↗
  • InjurySep 4, 2026Migration

    It was reported that the patient with this Implantable Neurostimulator (INS) experienced discomfort at the battery implant site. Additional information received indicated that the patient had experienced weight loss, resulting in the battery becoming more superficial and causing discomfort. The patient subsequently underwent device explantation. No further patient complications were reported.

    Patient problems: Discomfort; Weight Changes

    MAUDE report 50600337 ↗
  • InjurySep 4, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG underwent device explantation due to a pocket site infection. The patient had undergone multiple reprogramming sessions prior to explantation. Follow up information confirmed that the reprogramming was performed due to a lack of symptom relief. The infection was treated with antibiotics and explantation of the device. At the time of follow-up, the patient was reported to be stable. No further patient complications were reported.

    Patient problems: Unspecified Infection

    MAUDE report 50600332 ↗
  • InjurySep 3, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Recharge-Free SNM IPG elected to have their device explanted after it being turned off for some time. The patient noted that another unrelated procedure has been helping their overactive bladder symptoms, and their device was no longer needed. The procedure was completed. No patient complications were reported as a result of this event.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50599878 ↗
  • InjurySep 3, 2026High impedance; Migration

    It was reported that the patient with the neurostimulator had a Clinician Programmer (CP) error showing red open impedances from the device. The patient reported that the symptoms returned. No reprogramming was performed because of the open impedances. The device was left off, and the physician ordered an X-ray. The images did not show that there was any damage to the stimulator. The patient had surgery to have their Neurostimulator and Tined Lead replaced. During the procedure, the physician noted that due to implant location and patient anatomy of the loose pocket and skin, the physician believed the Tined Lead got twisted on itself from movement in pocket and that is what caused damage. The physician said it was the patient anatomy or external damage, not product error.

    Patient problems: Incontinence

    MAUDE report 50599754 ↗
  • InjurySep 3, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with this Recharge-Free SNM internal programmer was feeling heat during their MRI, but the technician confirmed that their device was turned off. An MRI readiness check was performed, but the MRI was aborted. The patient later underwent a pocket revision. Their stimulation settings remained the same and the patient did not need any additional changes.

    Patient problems: Burning Sensation

    MAUDE report 50599748 ↗
  • InjuryAug 31, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that a patient with a Neurostimulator and an SNM Tined Lead was experiencing redness and itchiness in the implant site with \"dots all over.\" Their doctor advised the patient was having a reaction to the suture used and should monitor for symptoms of infection. The patient went to the emergency room after noticing their incision had opened and the device was visible. This was caused by infection, and they were given antibiotics. The patient's doctor reached out to confirm the patient would have their implant removed due to wound dehiscence. The explant was successfully completed. There was no additional patient complications reported.

    Patient problems: Erythema; Itching Sensation; Post Operative Wound Infection; Wound Dehiscence

    MAUDE report 50515471 ↗
  • InjuryAug 31, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient with this Neurostimulator (INS) went to the emergency department due to pain. Upon examination, it was noted that the patient's INS had eroded through the skin. Then the patient had surgery to explant their INS and Tined Lead. There was no infection noted at the time, but they were waiting for the report on the intra-op swab. The patient was closed up and sent home. Additionally, per the physician, there was no infection present from the swab.

    Patient problems: Erosion; Pain

    MAUDE report 50515465 ↗

FDA clearance and classification

The FDA regulates product code EZW (stimulator, electrical, implantable, for incontinence) under 21 CFR 876.5270 as a Class III device. 21 CFR 876.5270 ↗

Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Axonics 4101

Has the Axonics 4101 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10810005340455), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Axonics 4101?

The FDA's MAUDE database lists 818 adverse event reports for this device, received between Jun 29, 2022 and Sep 30, 2026. In those reports, the most common specific device problems are “Migration” (114), “Lack of Effect” (45) and “High impedance” (32); the most common patient problems are “Pain” (185), “Discomfort” (162) and “Unspecified Infection” (152). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Axonics 4101?

1 report is classified as a death, 795 as injuries and 22 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Axonics 4101 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the Axonics 4101, and is it still sold?

The FDA's device database lists Axonics Modulation Technologies, Inc. as the company responsible for it (brand Axonics, model 4101). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Stimulator, Electrical, Implantable, For Incontinence devices