MIDAS REX MR8 MR8-AA10DKRecalls & reported problems

Medtronic Powered Surgical Solutions · ATT MR8-AA10DK MR8 10CM ANGLED DK 2.4MM · Class 2

Adverse event reports
10
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00763000440855), received between Sep 17, 2024 and Jun 24, 2026 — classified as 10 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 5 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component7
  • Vibration4
  • Naturally Worn2
  • Overheating of Device2

Patient problems

  • No Clinical Signs, Symptoms or Conditions10
  • Insufficient Information1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 24, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING PRE-OP A DROPPED BEARING WAS OBSERVED IN THE DEVICE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25604507 ↗
  • MalfunctionJun 18, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT PRIOR TO USE, ATTACHMENT HAD BEARING DROPPED. IT WAS REPORTED THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25542415 ↗
  • MalfunctionJun 17, 2026Overheating of Device

    IT WAS REPORTED THAT THE ATTACHMENT WAS OVERHEATING PRIOR TO USE. IT WAS REPORTED THAT THERE WAS NO PATIENT INVOLVEMENT. ADDITIONAL INFORMATION WAS RECEIVED STATING THAT BEARING FALL OUT WERE FOUND DURING EVALUATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25529784 ↗
  • MalfunctionJun 17, 2026Naturally Worn

    IT WAS REPORTED THAT THE ATTACHMENT HAD A NOISY BEARING. IT WAS REPORTED THAT THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25528146 ↗
  • MalfunctionJun 5, 2026Detachment of Device or Device Component

    IT WAS REPORTED THAT PRIOR TO USE, BEARING DISLODGED. AT THE TIME OF REPORT THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25403297 ↗
  • MalfunctionSep 2, 2025Vibration; Detachment of Device or Device Component; Vibration; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING MICROVASCULAR DECOMPRESSION SURGEON DESCRIBED SOME CHATTERING OF THE BURR AND THE BALL BEARINGS AND RINGS FELL OUT OF THE ATTACHMENT. NO PATIENT IMPACT REPORTED. IT WAS ALSO REPORTED THAT THE SURGICAL TEAM CHANGED THE ATTACHMENT FOR A NEW ONE AND THE CASE CONTINUED.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 22932098 ↗
  • MalfunctionJun 20, 2025Vibration; Detachment of Device or Device Component; Vibration; Detachment of Device or Device Component

    IT WAS REPORTED THAT THAT DURING SPINAL DECOMPRESSION PROCEDURE THE ATTACHMENT WAS DISPLAYING EXCESSIVE VIBRATION AND WHEN THE TOOL WAS REMOVED A METAL RING CAME OUT FROM ATTACHMENT. NO PATIENT IMPACT REPORTED. THE PROCEDURE WAS COMPLETED WITH BACKUP PRODUCT. ADD ITIONAL INFORMATION REGARDING THE PATIENT IMPACT WAS BEING FOLLOWED UP FROM THE FACILITY. ON ADDITIONAL FOLLOW UP THERE WAS NO PATIENT IMPACT ASSOCIATED WITH THIS EVENT. THE PROCEDURE WAS COMPLETED WITH BACKUP PRODUCT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22296086 ↗
  • MalfunctionMay 7, 2025Vibration; Detachment of Device or Device Component; Vibration; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING THE SPINAL DECOMPRESSION PROCEDURE, SURGEON NOTED EXCESSIVE VIBRATION AND CHATTER DURING A SPINAL DECOMPRESSION PROCEDURE. WHEN THE ATTACHMENT WAS REMOVED IT WAS NOTED THAT THE DISTAL BEARING WAS DISLODGED AND STILL SITTING ON THE SHAFT OF THE DISSECTION TOOL. NO PATIENT IMPACT REPORTED. IT WAS ALSO REPORTED THAT THERE WAS NO INTERVENTION PERFORMED, NO DAMAGED PIECE REMAINED IN THE PATIENT'S BODY, AND THERE WAS NO DELAY IN PROCEDURE. THE PROCEDURE WAS COMPLETED WITH BACKUP PRODUCT(S). ON FOLLOW-UP IT WAS REPORTED THAT THERE WAS NO PATIENT OR STAFF IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21975347 ↗
  • MalfunctionMar 7, 2025Overheating of Device; Vibration; Naturally Worn; Overheating of Device; Vibration; Naturally Worn

    IT WAS REPORTED THAT DURING A PROCEDURE, DRILL WAS DESCRIBED AS SHUDDERING OR JUMPING WHEN APPLIED TO BONE. APPEARS TO BE A DISTAL B EARING ISSUE AS HAS BEEN PREVIOUSLY NOTED AT THIS SITE. THIS ATTACHMENT WAS A WARRANTY REPLACEMENT FOR A PREVIOUS INCIDENT. IT WAS REPORTED THAT THERE WAS NO PATIENT IMPACT. IT WAS ALSO REPORTED THAT THERE WAS NO INTERVENTION PERFORMED, NO DAMAGED PIECE REMAINED IN THE PATIENT'S BODY, AND THERE WAS NO DELAY IN PROCEDURE. THE PROCEDURE WAS COMPLETED WITH BACKUP PRODUCT(S). ON FURTHER INFORMATION IT WAS STATED AS DEVICE OVERHEATING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21543766 ↗
  • MalfunctionSep 17, 2024Detachment of Device or Device Component; Detachment of Device or Device Component

    REPAIR REQUEST INITIATED FOR DEVICE WITH THE REPORT OF BEARING DETACHMENT. IT WAS REPORTED THERE WAS NO PATIENT INVOLVEMENT. REPAIR IS BEING ESCALATED TO PRODUCT EVENT DUE TO REASON FOR THE RETURN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20234401 ↗