Anteralign Spinal System with Titan nanoLock Surface technology 46831220Recalls & reported problems
Medtronic Sofamor Danek, Inc. · MINIPLATE 46831220 SMALL 12X20MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000510763), received between Feb 24, 2023 and Feb 24, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 24, 2023Use of Device Problem; Migration; Use of Device Problem; Migration
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER (HCP) VIA A MEDTRONIC REPRESENTATIVE REGARDING A PATIENT WHO WAS IMPLANTED WITH A CAGE, BONE SCREW AND MINIPLATE USED FOR CONTINUED USE. IT WAS REPORTED THAT THE CAGE INSERTED INTO L4/5 HAS BACKED OUT. LEVELS IMPLANTED WAS L3/4, L4/5. IT WAS ALSO UNDERSTOOD THAT PATIENT WAS SUFFERING ADULT SPINAL DEFORMITY. THERE WERE NO FURTHER COMPLICATIONS THAT WERE REPORTED. CAGE WAS IMPLANTED AT THE SURGERY ON JANUARY 25 FOR L3/4 AND L4/5, AND BACK-OUT WAS DETECTED IN L4/5 ON JANUARY 27. ON JANUARY 30, REOPERATION WAS PERFORMED AND THE CAGE WAS REMOVED AND A SLIGHTLY LARGER SIZE WAS PLACED AGAIN WITHOUT A MINI PLATE. POSTERIOR FIXATION WAS ADDED, AND THE OPERATION WAS COMPLETED SUCCESSFULLY. A REAR FIXATION WAS ADDED. THEIR WAS ALSO A HUMAN ERROR IN THE EVENT. ALSO, BONE SCREW AND MINIPLATE WERE ATTACHED AND IMPLANTED WITH THE REPORTED CAGE ON 25TH JAN. BOTH MINIPLATE AND BONE SCREW MIGRATED ALONG WITH THE CAGE. IN THE REVISION OP ON JAN/30, THE CAGE WAS REMOVED WITH THE BONE SCREW AND MINIPLATE, AND THEN A LITTLE LARGER CAGE WAS IMPLANTED WITHOUT MINIPLATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16437484 ↗
Other Intervertebral fusion device with integrated fixation, lumbar devices
- PIVOX™ Oblique Lateral Spinal System 2161001Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with integrated fixation, lumbar182 reports
- IdentiTi 232-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall8 reports
- IdentiTi 232-10-85-250Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall5 reports
- IdentiTi 132-10-85-300Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall3 reports
- MectaLIF Anterior 03.30.301Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall2 reports
- IdentiTi 232-10-85-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall2 reports
- IdentiTi 232-11-90-350Alphatec Spine, Inc. · Intervertebral fusion device with integrated fixation, lumbar1 recall1 report
- MectaLIF Anterior 03.30.302Medacta International SA · Intervertebral Fusion Device With Integrated Fixation, Lumbar1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page