Medtronic Reusable Instruments 5485930Recalls & reported problems
Medtronic Sofamor Danek, Inc. · EXTENDER 5485930 5.5/6.0 ROCKER EXTENDER · Class 1
All models of Medtronic Reusable Instruments (36)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00763000572808), received between Jan 6, 2025 and Apr 3, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Mechanical Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Mechanical Problem2
- Product Quality Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 3, 2025Mechanical Problem; Product Quality Problem; Mechanical Problem; Product Quality Problem
INFORMATION RECEIVED FROM MANUFACTURER REPRESENTATIVE REGARDING A PRODUCT USED FOR THE SPINAL THERAPY. IT WAS REPORTED THAT, UPON TESTING THE REDUCERS, PRIOR TO USE IN THE OPERATING ROOM, IT WAS FOUND THAT THE INNER SLEEVE DOES NOT REDUCE ENTIRELY. IT APPEARS THAT EITHER THE INNER SLEEVE GETS CAUGHT ON THE LIP OF THE OUTER REDUCER OR THE OUTER REDUCER HAS TOO NARROW OF AN OPENING FOR THE INNER REDUCER TO PASS THROUGH. THERE WAS NO PATIENT INVOLVED, NO FURTHER COMPLICATIONS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21759845 ↗MalfunctionJan 6, 2025Mechanical Problem; Mechanical Problem
INFORMATION WAS RECEIVED FROM A USER FACILITY VIA MANUFACTURING REPRESENTATIVE REGARDING DEVICES USED FOR THORACOLUMBAR FUSIONS. IT WAS REPORTED THAT THE REDUCER WAS BROKEN, IT DOESN'T GRAB TO THE TULIPS HEADS. WHEN IT DOES GRAB, IT DOESN'T LET GO OF THE TULIP. ALSO, WHEN REDUCING, IT CATCHES AND DOESN'T WANT TO REDUCE. THE EXTENDER WAS BROKEN AS WELL. THEY ARE NOT FUNCTIONING HOW THEY SHOULD BE AND WERE NOT USABLE IN SURGERY. NO SURGEON USED THESE AND THEY WERE NOT USED IN A CASE. NO PATIENT WAS INVOLVED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21076872 ↗
Other Orthopedic manual surgical instrument devices
- AML EXCEL 2001-42-000Depuy (Ireland) · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT2,009 reports
- NA 03.010.523Synthes GmbH · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,208 reports
- EXPRESSEW 214141Medos International Sàrl · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT1,166 reports
- N/A 9560524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT866 reports
- INHANCE 6500-11-104Depuy (Ireland) · Orthopedic manual surgical instrument831 reports
- INHANCE 6500-11-102Depuy (Ireland) · Orthopedic manual surgical instrument567 reports
- R3 71364450Smith & Nephew, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT520 reports
- N/A 9561524Medtronic Sofamor Danek, Inc. · ORTHOPEDIC MANUAL SURGICAL INSTRUMENT494 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page