Sentrant™ SENSH1628W (UDI 00763000716417)Recalls & reported problems

Medtronic, Inc. · SENTRANT INTRODUCER SHEATH 16 FR X 28 CM · Class 2

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00763000716417), received between Jan 26, 2026 and Jan 26, 2026 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Perforation of Vessels1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 26, 2026Adverse Event Without Identified Device or Use Problem

    AN ETBF2813C124EJ STENT GRAFT WAS IMPLANTED DURING THE ENDOVASCULAR TREATMENT OF A 63MM AAA. IT WAS REPORTED THAT DURING THE INDEX PROCEDURE THE PATIENT HAD BARE-METAL STENTS PLACED FROM BOTH CIAS TO THE EIAS, WITH THE EIA OCCLUDED. ALTHOUGH STENOSIS WAS OBSERVED IN THE LEFT ACCESS, IT WAS DETERMINED THAT EVAR COULD PROCEED IF PTA WAS PERFORMED FIRST. AFTER APPLYING A 6MM PTA BALLOON TO THE LEFT ACCESS, AN ATTEMPT WAS MADE TO ADVANCE THE ETBF2813C124EJ FROM THE RIGHT ACCESS, BUT IT GOT STUCK AROUND THE CIA AND WAS DIFFICULT TO ADVANCE. IT WAS EVENTUALLY ADVANCED, AND THE MAIN BODY WAS DEPLOYED. AN NON-MEDTRONIC LIMB WAS PLACED ON THE CONTRALATERAL SIDE, DEPLOYED UP TO THE MAIN BODY ON THE IPSILATERAL SIDE, AND THEN REMOVED. DURING REMOVAL, ACCESS DAMAGE WAS A CONCERN, SO BLOOD PRESSURE WAS MONITORED. ALTHOUGH IT DROPPED SLIGHTLY, THE REPLACEMENT OF A SENTRANT SHEATH MADE IT UNCLEAR WHETHER DAMAGE HAD OCCURRED. AN NON-MEDTRONIC LIMB WAS PLACED ON THE IPSILATERAL DISTAL SIDE AND A TOUCH-UP WAS PERFORMED. FINAL ANGIOGRAPHY CONFIRMED THE ABSENCE OF ANY ENDOLEAK. A NON-MEDTRONIC SHEATH WAS INSERTED INTO THE LEFT FA WAS LOWERED TO THE FEMORAL HEAD AREA, AND ANGIOGRAPHY REVEALED A LOCALIZ

    Patient problems: Perforation of Vessels

    MAUDE report 24176301 ↗

Other Introducer, catheter devices

All Introducer, catheter devices →