Intellis™ AdaptiveStim™ 97715Recalls & reported problems

Medtronic, Inc. · INS 97715 INTELLIS US EMAN CARDIO · Class 3 · Implant

All models of Intellis AdaptiveStim (3)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00763000849047), received between May 7, 2025 and Jul 13, 2026 — classified as 4 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Communication or Transmission Problem” (3 reports).

9 other recalls cover devices cleared under the same FDA submission (P840001); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 1 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Communication or Transmission Problem3
  • Failure to Interrogate3
  • Insufficient Device Problem Information3
  • Charging Problem2
  • Energy Output Problem2
  • Therapeutic or Diagnostic Output Failure2
  • Battery Problem1
  • Failure to Deliver Energy1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • Insufficient Information1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 13, 2026Failure to Interrogate; Overheating of Device; Communication or Transmission Problem; Insufficient Device Problem Information

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25804800 ↗
  • InjuryDec 11, 2025Failure to Interrogate; Energy Output Problem; Charging Problem; Communication or Transmission Problem; Therapeutic or Diagnostic Output Failure; Failure to Interrogate; Energy Output Problem; Charging Problem; Communication or Transmission Problem; Therapeutic or Diagnostic Output Failure

    CALLER REPORTS PATIENT CANNOT INCREASE OR DECREASE IS SETTING. PATIENT CAME ONLINE, PATIENT INDICATED HE HAS BEEN SEEING AN ERROR MESSAGE: SETTING NOT AVAILABLE. CANNOT PROVIDE YOUR DESIRED INTENSITY SETTINGS SINCE (B)(6) 2025. PATIENT INDICATED HE NOTIFIED MANUFACTURER REPRESENTATIVE (REP) SINCE THEN. PATIENT ALSO INDICATED HE IS HAVING A HARD TIME CONNECTING AND CHARGING HIS IMPLANT. INS CURRENTLY AT 30% CHARGE. PATIENT DID NOT BRING HIS CHARGING EQUIPMENT FOR FURTHER TROUBLESHOOTING. SUGGEST PATIENT CALL TO PS FOR FURTHER TROUBLESHOOTING ON CHARGING. CALLER REPORTS PATIENT USING THE FOLLOWING ELECTRODES. ELECTRODE IMPEDANCE PERFORMED: GROUP A: PROGRAM 1. ELECTRODES: 3+5- : 2170 OHMS PROGRAM 2. ELECTRODES: 9/10: 1680 OHMS PROGRAM 3. 10, 11, 12, 13, 14, 15 REFERENCE 10: ELECTRODE 11: 1610 OHMS ELECTRODE 12: 2080 OHMS ELECTRODE 13: 2130 OHMS ELECTRODE 14: 2280 OHMS ELECTRODE 15: 2160 OHMS REFERENCE 11 ELECTRODE 12: 1530 OHMS ELECTRODE 13: 1810 OHMS ELECTRODE 14: 2030 OHMS ELECTRODE 15: 1950 OHMS REFERENCE 12: ELECTRODE 13: 1630 OHMS ELECTRODE 14: 2050 OHMS ELECTRODE 15: 2050 OHMS REFERENCE 13: ELECTRODE 14: 1680 OHMS ELECTRODE 15: 1910 OHMS REFERENCE 14 ELECTRODE 15: 1640 OHMS GROU

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23777221 ↗
  • InjuryNov 4, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    INFORMATION WAS RECEIVED FROM A PATIENT (PT) WITH AN IMPLANTABLE NEUROSTIMULATOR (INS). THE REASON FOR CALL WAS 3 OR 4 MONTHS AGO THEIR INS BATTERY FAILED; PT WAS TOLD ONLY 4 BATTERIES FAILED WITHIN 100,000 BATTERIES. NO SYMPTOMS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23465699 ↗
  • InjurySep 9, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    INFORMATION WAS RECEIVED FROM A PATIENT (PT) WITH AN IMPLANTABLE NEUROSTIMULATOR (INS). THE REASON FOR CALL WAS 3 OR 4 MONTHS AGO THEIR INS BATTERY FAILED; PT WAS TOLD ONLY 4 BATTERIES FAILED WITHIN 100,000 BATTERIES. NO SYMPTOMS WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23006567 ↗
  • InjuryJul 17, 2025Failure to Interrogate; Battery Problem; Charging Problem; Communication or Transmission Problem; Failure to Interrogate; Battery Problem; Charging Problem; Communication or Transmission Problem

    ADDITIONAL INFORMATION WAS RECEIVED FROM PATIENT (PT) STATING THE BATTERY FAILURE ¿ CHARGE WAS DONE WITH NO CONNECTIONS LOOSE. WE CHANGED ALL THE OUTSIDE COMPONENTS AND BATTERY, CHANGING OUT ALL THE OUTSIDE COMPONENTS + BATTERY. TO BE HONEST WITH YOU, THE PROCESS IS LESS THAN DESIRED. I DON¿T HAVE FAITH IN YOUR FACTORY AGENT. DON¿T APPEAR TO BE VERY QUALIFIED, JUST KEEP SENDING FOR PARTS. I UNDERSTAND THIS IS AN ODD PROBLEM BUT THAT IS STILL NOT AN ACCEPTABLE EXCUSE. I SELECTED THIS BECAUSE I THOUGHT YOU WERE THE BEST DECISION. SEEMS LIKE A POOR DECISION NOW. WE SUPPOSEDLY HAVE AN NEW INTERNAL BATTERY COMING, SURGERY TO REPLACE IS ON AUGUST 5TH. I SINCERELY HOPE WE GET IT BY THEN, IF NOT I WILL BE FORCED TO TAKE LEGAL ACTION. JUST TO GIVE YOU MORE BACKGROUND, THE STIMULATOR HAS REDUCED MY PAIN SUBSTANTIALLY AND NOW I AM IN WORSE SHAPE THAN EVER. I CHOSE THIS BECAUSE MY OLDEST SON HAS A DEVICE THAT REDUCED SEIZURES FROM A BRAIN INJURY AND WAS VERY IMPRESSED WITH THE DEVICE¿S PERFORMANCE AND THE LOCAL REPS. ON A POSITIVE NOTE, THE REP HAS BEEN VERY GOOD TO WORK WITH. LAST BUT NOT LEAST, I WANT YOU TO KNOW I AM IN THE HVAC SERVICE BUSINESS AND WOULD BE VERY DISAPPOINTED IF MY PEOPLE W

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22528436 ↗
  • MalfunctionMay 7, 2025Failure to Deliver Energy; High impedance; Energy Output Problem; Therapeutic or Diagnostic Output Failure; Failure to Deliver Energy; High impedance; Energy Output Problem; Therapeutic or Diagnostic Output Failure

    CALLER TOLD BY PT THAT PT SEEING SETTINGS NOT AVAILABLE ON THEIR CONTROLLER STARTING ON MAY 4. CALLER SAW PT MAY 5 TO DO REPROGRAMMING. PT DID HAVE HIGH IMPEDENCE'S ON ONE ELECTRODE (WHICH ONE IS UNKNOWN BY CALLER) BUT THIS WASN'T BEING USED IN PROGRAMMING. PT USING DTM STYLE OF PROGRAMMING BUT WAS FEELING STIMULATION YESTERDAY DURING REPROGRAMMING SESSION. CALLER MADE SOME CHANGES TO PT'S SETTINGS INCLUDING LOWERING PULSE WIDTH TO A MUCH LOWER LEVEL. PER CALLER, PT USING ABOUT 4MA FOR INTENSITY. THE PT HAS ONLY BEEN USING GROUP B SO UNKNOWN IF GETTING OUT OF REGULATION (OOR) ON OTHER GROUPS. CALLER IS GOING TO TRY TO SEE PT TOMORROW AGAIN.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 21976820 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under P840001. One submission often covers many models, so check the product and lot details in each record.

  • Z-0372-2025 · Sep 18, 2024 · Open, Classified
    Medtronic Recharger Kits, RS6230, RS7230, and RS5220A, containing components WR9230 and WR9220A Recharger for rechargeable implantable neurostimulators. The Rechargers are used wi
  • Z-1691-2024 · Mar 28, 2024 · Open, Classified
    Intellis AdaptiveStim Product Number 97715, Spinal Cord Stimulator
  • Z-0780-2024 · Dec 19, 2023 · Open, Classified
    Model A710 Intellis Clinician Programmer Application, version 2.0.97
  • Z-2159-2021 · Jul 9, 2021 · Open, Classified
    Medtronic Vectris SureScan MRI, Catalog Numbers: a) 977A260 b) 977A275 c) 977A290
  • Z-1926-2016 · May 3, 2016 · Terminated
    Medtronic RestoreSensor, Model 37714; and, RestoreSensor SureScan, (MRI), Model 97714, Implantable Neurostimulators. Used to treat chronic, intractable pain of the trunk and/or li
  • Z-1147-2015 · Jan 9, 2015 · Terminated
    The Medtronic, Quadripolar ITREL 3 IPG, Model 7425, is a multiprogrammable device designed for use in the Stimulation of the Central Nervous System, Peripheral Nervous System, or m
  • Z-1524-2014 · Feb 27, 2014 · Terminated
    Medtronic neurostimulators. Restore (37711), RestoreADVANCED (37713), RestoreADVANCED SureScan MRI (97713), RestoreSENSOR (37714), RestoreSENSOR SureScan MRI (97714), PrimeAdvanced
  • Z-0278-2014 · Sep 30, 2013 · Terminated
    Medtronic RestoreUltra, model 37712, and RestoreSensor, model 37714, Multi-program Rechargeable Neurostimulator for Spinal Cord Stimulation.
  • Z-1536-06 · Aug 2, 2006 · Terminated
    Medtronic 3777 Lead Kit, 1x8 Low Impedance Lead Kit for Spinal Cord Stimulation (SCS). Manufactured at: Medtronic, Inc., Villalba, Puerto Rico USA. Medtronic, Inc., Minneapolis

Other Stimulator, spinal-cord, totally implanted for pain relief devices

All Stimulator, spinal-cord, totally implanted for pain relief devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page