Bardex® Lubri-Sil® I.C. All-Silicone Foley Catheter 73018SIRecalls & reported problems
C. R. Bard, Inc. · Bardex® Lubri-Sil® I.C. All-Silicone Coated 30 cc 3 way Foley Catheter · Class 2
All models of Bardex Lubri-Sil I.C. All-Silicone Foley Catheter (26)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00801741025495), received between Apr 23, 2025 and Sep 3, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak3
- Material Puncture/Hole3
Patient problems
- No Clinical Signs, Symptoms or Conditions6
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 3, 2026Material Puncture/Hole
It was reported that during use customer observed leakage at the junction of the foley catheter draining site. This appear to be a product defect. this event happened in Operation theatre. They have discarded the catheter once they find leakage on the catheter 18fr 3way silicone.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50578071 ↗MalfunctionSep 29, 2025Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT, CUSTOMER OBSERVED LEAKAGE AT THE JUNCTION OF THE FOLEY CATHETER DRAINING SITE. THIS APPEAR TO BE A PRODUCT DEFECT. THIS EVENT HAPPENED IN OPERATION THEATRE. LAST EVENT INCIDENT HAPPENED THE SAME LEAKAGE ISSUE WHICH WAS REPORTED ON (B)(6) 2025 IN MEDICAL ICU. THIS INCIDENT WAS SECOND TIME IN THIS HOSPITAL. CATHETER WAS DISCARDED ONCE USER FIND LEAKAGE ON THE CATHETER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23167317 ↗MalfunctionAug 18, 2025Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT CUSTOMER OBSERVED LEAKAGE AT THE JUNCTION OF THE FOLEY CATHETER CONNECTING SITE. THIS APPEARS TO BE A PRODUCT DEFECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22826980 ↗MalfunctionJun 26, 2025Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT POST PROCEDURE HAD TO INSERT THE FOLEY CATHETER, 3 OUT OF FIRST 2 CATHETERS HAD LEAKAGE AT THE IRRIGATION PORT ACCESS PARTS. FOR LOT#NGJR1639 AND LOT#NGJX6161.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22338865 ↗MalfunctionJun 26, 2025Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT POST PROCEDURE HAD TO INSERT THE FOLEY CATHETER, 3 OUT OF FIRST 2 CATHETERS HAD LEAKAGE AT THE IRRIGATION PORT ACCESS PARTS. FOR LOT#NGJR1639 AND LOT#NGJX6161.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22336715 ↗MalfunctionApr 23, 2025Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT CUSTOMER WAS CONTINUING TO HAD PROBLEMS WITH LEAKS IN THEIR FOLEY CATHETERS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21892868 ↗
Other CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES devices
- Bardex® Lubri-Sil® I.C. Temperature-Sensing All-Silicone Foley Catheter 119314C. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES1 recall3,889 reports
- Bardex® I.C. Foley Catheter 0165SI14C. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES1,994 reports
- Bardex® I.C. Foley Catheter 0165SI16C. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES1,052 reports
- Bardex® Lubri-Sil® I.C. All-Silicone Foley Catheter 1758SI14C. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES778 reports
- Bardex® I.C. Temperature Sensing Foley Catheter 129414MC. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES436 reports
- Bardex® Lubri-Sil® I.C. All-Silicone Temp Sensing Foley Catheter 119316MC. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES231 reports
- Bardex® Lubri-Sil® I.C. Temperature-Sensing All-Silicone Foley Catheter 119316C. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES198 reports
- Bardex® I.C. Foley Catheter 0165SI18C. R. Bard, Inc. · CATHETER, UROLOGICAL (ANTIMICROBIAL) AND ACCESSORIES181 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page