COMPOSIX 0144680Recalls & reported problems

Davol Inc. · Composix L/P Mesh with PS Echo PS Positioning System, 6.2" x 8.2" (15.9 cm x 21.0 cm), Ellipse · Class 2 · Implant

Adverse event reports
7
Deaths reported
0
Injuries reported
6
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 00801741031359), received between Oct 5, 2018 and Apr 21, 2026 — classified as 6 injuries, 1 malfunction.

The most frequently reported specific device problem is “Defective Device” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Defective Device4
  • Insufficient Device Problem Information4
  • Patient-Device Incompatibility3
  • Detachment of Device or Device Component1
  • Patient Device Interaction Problem1

Patient problems

  • Adhesion(s)5
  • Hernia5
  • Disability3
  • Injury3
  • Pain2
  • Abdominal Pain1
  • Device Embedded In Tissue or Plaque1
  • Erosion1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 21, 2026Patient-Device Incompatibility

    PER INFORMATION PROVIDED: ON (B)(6) 2020 - PATIENT WAS DIAGNOSED WITH INCISIONAL HERNIA THEREBY UNDERWENT LAPAROSCOPIC REPAIR WITH IMPLANT OF COMPOSIX L/P USING ECHO MESH (DEVICE 1). PER OP NOTES, ¿OMENTAL ADHESIONS WERE TAKEN DOWN. THE HERNIA DEFECT WAS NOTED AND REDUCED. A COMPOSIX L/P USING ECHO MESH (DEVICE 1) WAS PLACED AND TACKED CIRCUMFERENTIALLY USING SPIRAL TACKS.¿ ON (B)(6) 2020 - PATIENT WAS DIAGNOSED WITH RECURRENT INCISIONAL HERNIA THEREBY UNDERWENT LAPAROSCOPIC REPAIR WITH IMPLANT OF COMPOSIX L/P MESH (DEVICE 2). PER OP NOTES, ¿OMENTAL ADHESIONS WERE TAKEN DOWN. THE PRIOR MESH (DEVICE 1) WAS NOTED TO BE JUST BELOW THE FASCIAL DEFECT. THE HERNIA DEFECT WAS REDUCED. A COMPOSIX L/P MESH (DEVICE 2) WAS PLACED AND TACKED CIRCUMFERENTIALLY.¿ ON (B)(6) 2021 - PATIENT WAS DIAGNOSED WITH RECURRENT INCISIONAL HERNIA AND DIVERTICULOSIS THEREBY UNDERWENT LAPAROSCOPIC CONVERTED TO OPEN REPAIR WITH EXCISION OF COMPOSIX L/P USING ECHO MESH (DEVICE 1) AND COMPOSIX L/P (DEVICE 2). PER OP NOTES, ¿DENSE ADHESIONS BETWEEN OMENTUM AND PRIOR MESHES (DEVICE 1 AND 2) WERE LYSED. THERE WAS A RECURRENT HERNIA AND REDUCED. ALL THE PRIOR ABDOMINAL MESHES (DEVICE 1 AND 2) WERE EXCISED END REMOVED

    Patient problems: Adhesion(s); Hernia

    MAUDE report 24939503 ↗
  • InjurySep 5, 2025Patient-Device Incompatibility; Patient-Device Incompatibility

    PER INFORMATION PROVIDED: (B)(6) 2012 - PATIENT WAS DIAGNOSED WITH INCARCERATED INCISIONAL HERNIA THEREBY UNDERWENT LAPAROSCOPIC REPAIR WITH IMPLANT OF COMPOSIX L/P MESH WITH ECHO (DEVICE 1) AND COMPOSIX L/P MESH (DEVICE 2). PER OP NOTES, "A COMPOSIX L/P MESH WITH ECHO (DEVICE 1) AND COMPOSIX L/P MESH (DEVICE 2) WERE PLACED INTO THE ANTERIOR ABDOMINAL WALL USING TACKS." (B)(6) 2019 - PATIENT WAS DIAGNOSED WITH MULTIPLE RECURRENCE OF VENTRAL HERNIA AND EXTENSIVE LYSIS OF ADHESIONS THEREBY UNDERWENT REPAIR WITH REMOVAL OF OLD MESH (DEVICE 1 AND DEVICE 2). PER OP NOTES, "LYSIS OF ADHESIONS WAS PERFORMED. THE ENTIRE OLD MESHES (DEVICE 1 AND DEVICE 2) WERE REMOVED. DISSECTION WAS CARRIED TO THE DENSE SCAR TISSUE. A SYNTHETIC MESH WAS PLACED."

    Patient problems: Adhesion(s); Hernia; Scar Tissue

    MAUDE report 22975579 ↗
  • InjuryNov 8, 2020Defective Device; Patient-Device Incompatibility; Insufficient Device Problem Information; Defective Device; Patient-Device Incompatibility; Insufficient Device Problem Information

    ATTORNEY ALLEGES THAT THE PATIENT UNDERWENT SURGERY FOR IMPLANT OF AN UNSPECIFIED BARD/DAVOL COMPOSIX L/P ON (B)(6) 2011. AS REPORTED, THE PATIENT IS MAKING A CLAIM FOR AN ADVERSE PATIENT OUTCOME AGAINST THE COMPOSIX L/P. ATTORNEY ALLEGES THAT THE PATIENT HAD SUBSEQUENT SURGICAL INTERVENTION DUE TO THE HERNIA MESH DEVICE. IT IS ALSO ALLEGED THAT THE PATIENT EXPERIENCED EMOTIONAL DISTRESS AND THE DEVICE WAS DEFECTIVE.

    Patient problems: Abdominal Pain; Adhesion(s); Erosion; Hernia; Injury

    MAUDE report 10806728 ↗
  • MalfunctionApr 10, 2020Detachment of Device or Device Component; Detachment of Device or Device Component

    AS REPORTED PER MEDWATCH FORM (B)(4): "WHEN USING THE MESH WITH THE ECHO POSITIONING SYSTEM, THE YELLOW PLASTIC ANCHOR FELL OFF OF THE BLUE TUBING INSIDE OF THE PATIENT (IT FELL OFF AFTER THE TUBING WAS CUT). THE SURGICAL TEAM SEARCHED THE ABDOMEN EXTENSIVELY WITH THE LAPAROSCOPE AND CHECKED THE TROCARS, INCLUDING CHECKING UNDER THE RUBBER GASKET OF THE 11MM OPTIVIEW TROCAR THAT WAS USED WITH THE MESH SYSTEM. RADIOLOGY WAS CALLED AND A FLAT PLATE WAS TAKEN OF A SECOND PIECE OF THE SAME MESH/POSITIONING SYSTEM. THE PIECE WAS NOT RADIOPAQUE AND DID NOT HAVE A MARKER, SO THE SURGEON OPTED NOT TO X-RAY THAT PATIENT'S ABDOMEN. THE SECOND PIECE WAS TAKEN BY THE SURGEON TO SHOW THE PATIENT'S FAMILY." THIS WAS A HERNIA REPAIR SURGERY. THE FOLLOWING WAS PROVIDED IN FOLLOW UP WITH THE HOSPITAL CONTACT: THE CASE WAS A LAPAROSCOPIC INCISIONAL REPAIR. THE INFLATION TUBE WAS GRASPED AT THE RETRIEVAL LOOP WITH A CARTER THOMASON GRASPER. THE INFLATION ASSEMBLY WAS USED SUCCESSFULLY TO PLACE THE MESH. AS REPORTED, THE YELLOW ANCHOR WAS NOT VISUALIZED DURING THE INFLATION PROCESS. AS THE SURGEON WAS REMOVING THE INFLATION ASSEMBLY "IT GOT STUCK IN A PORT AND AS THE SURGEON ATTEMPTED TO REMOVE IT THE

    Patient problems: Device Embedded In Tissue or Plaque; No Known Impact Or Consequence To Patient

    MAUDE report 9948776 ↗
  • InjuryNov 8, 2019Defective Device; Insufficient Device Problem Information; Patient Device Interaction Problem; Defective Device; Insufficient Device Problem Information; Patient Device Interaction Problem

    ATTORNEY ALLEGES THAT THE PATIENT UNDERWENT SURGERY FOR IMPLANT OF TWO (2) UNSPECIFIED BARD/DAVOL VENTRIO (DEVICE #1) AND (DEVICE #2) ON (B)(6) 2010 AND UNSPECIFIED BARD/DAVOL COMPOSIX L/P (DEVICE #3) ON (B)(6) 2011. AS REPORTED, THE PATIENT IS MAKING A CLAIM FOR AN ADVERSE PATIENT OUTCOME AGAINST THE TWO (2) VENTRIO (DEVICE #1) AND (DEVICE #2) AND THE COMPOSIX L/P (DEVICE #3). AS REPORTED, THE ATTORNEY ALLEGES GENERAL ALLEGATIONS FOR "PAST, PRESENT, AND FUTURE DAMAGES, INCLUDING BUT NOT LIMITED TO, MENTAL AND PHYSICAL PAIN AND SUFFERING FOR SEVERE AND PERMANENT PERSONAL INJURIES SUSTAINED BY THE PATIENT."

    Patient problems: Adhesion(s); Disability; Hernia; Injury; Pain

    MAUDE report 9298228 ↗
  • InjuryOct 18, 2018Defective Device; Insufficient Device Problem Information; Defective Device; Insufficient Device Problem Information

    THE FOLLOWING WAS ALLEGED BY THE PATIENT'S ATTORNEY: ON (B)(6) 2011: THE PATIENT UNDERWENT SURGERY FOR IMPLANT OF A BARD/DAVOL VENTRALIGHT ST(DEVICE #1). ON (B)(6) 2013: THE PATIENT UNDERWENT SURGERY FOR IMPLANT OF A BARD/DAVOL COMPOSIX L/P(DEVICE #2). ON (B)(6) 2015: THE PATIENT UNDERWENT SURGERY FOR IMPLANT OF A BARD/DAVOL VENTRALIGHT ST(DEVICE #3). ON (B)(6) 2016: THE PATIENT UNDERWENT SURGERY FOR IMPLANT OF A BARD/DAVOL VENTRIO ST(DEVICE #4). THE PATIENT IS MAKING A CLAIM FOR AN ADVERSE PATIENT OUTCOME AGAINST THE VENTRALIGHT ST(DEVICE #1), COMPOSIX L/P (DEVICE #2), VENTRALIGHT ST (DEVICE #3), AND VENTRIO ST (DEVICE #4). THE ATTORNEY ALLEGES GENERAL ALLEGATIONS FOR "PAST, PRESENT, AND FUTURE DAMAGES, INCLUDING BUT NOT LIMITED TO, MENTAL AND PHYSICAL PAIN AND SUFFERING FOR SEVERE AND PERMANENT PERSONAL INJURIES SUSTAINED BY THE PATIENT.

    Patient problems: Disability; Injury; Pain

    MAUDE report 7981487 ↗
  • InjuryOct 5, 2018Defective Device; Insufficient Device Problem Information; Defective Device; Insufficient Device Problem Information

    THE FOLLOWING WAS ALLEGED BY THE PATIENT'S ATTORNEY: (B)(6) 2012: THE PATIENT UNDERWENT REPAIR OF A VENTRAL HERNIA. A BARD/DAVOL COMPOSIX L/P HERNIA MESH 6.2" X 6.8", LOT NUMBER HUVH1102 WAS IMPLANTED IN THE PATIENT DURING THIS REPAIR. (B)(6) 2014: THE PATIENT UNDERWENT SURGERY DUE TO CHRONIC ABDOMINAL WALL PAIN. DURING THE SURGERY, THE SURGEON NOTED, "SEVERE INTRA-ABDOMINAL ADHESIONS, MESH INGROWTH INTO LIVER." THE COMPOSIX L/P IMPLANTED IN PLAINTIFF FAILED TO REASONABLY PERFORM AS INTENDED.THE PRODUCT CAUSED SERIOUS INJURY AND HAD TO BE SURGICALLY REMOVED VIA INVASIVE SURGERY,NECESSITATING ADDITIONAL INVASIVE SURGERY TO REPAIR THE HERNIA THAT THE PRODUCT HAD INITIALLY BEEN IMPLANTED TO TREAT. THE PATIENT CONTINUES TO EXPERIENCE COMPLICATIONS RELATED TO THE BARD/DAVOL COMPOSIX L/P. THE PATIENT WILL LIKELY REQUIRE ADDITIONAL SURGERIES TO REPAIR THE DAMAGE FROM THE PRODUCT. THE BARD/DAVOL COMPOSIX L/P CAUSED SERIOUS INJURY AND HAD TO BE SURGICALLY REMOVED VIA INVASIVE SURGERY, NECESSITATING ADDITIONAL INVASIVE SURGERY TO REPAIR THE HERNIA THAT THE PRODUCT HAD INITIALLY BEEN IMPLANTED TO TREAT. IT IS ALLEGED THAT THE BARD/DAVOL COMPOSIX L/P IS DEFECTIVE. THE ATTORNEY ALLEGES THE PATI

    Patient problems: Adhesion(s); Disability; Hernia

    MAUDE report 7939570 ↗

Other Laparoscope, general & plastic surgery devices