PowerPICC Catheter with Sherlock Tip Location System (TLS) Stylet 9174108DRecalls & reported problems
Bard Access Systems, Inc. · PowerPICC Catheter with Sherlock Tip Location System (TLS) Stylet 4F Maximal Barrier Tray · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00801741035555), received between Apr 7, 2017 and May 15, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).
1 FDA recall record name this device's identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Recalls naming this device
- Mar 11, 2025Class IOpen, Classified
Catheters indicated for short-or-long term access to the central venous system have tubing that exceeded melt flow index specification (higher), which could lead to increased material fatigue leaks, which could lead to infiltration, extravasation, discomfort, phlebitis, bleeding, air embolism, foreign body embolism, infection and interruption to therapy.
Z-1507-2025 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Fluid/Blood Leak3
- Air Leak1
- Connection Problem1
- Difficult or Delayed Separation1
- Leak/Splash1
- Material Deformation1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient2
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 15, 2025Material Deformation; Difficult or Delayed Separation; Material Deformation; Difficult or Delayed Separation
ADDITIONAL INFORMATION RECEIVED ON 21-MAY-2025: DURING THE PROCEDURE. THE NURSE HAD THREADED THE LINE. WHEN SHE WENT TO "PEEL" AWAY THE SHEATH THE ORANGE PORTION ON ONE SIDE SNAPPED OFF INTO HER HAND. THE NURSE WAS ABLE TO CAREFULLY REMOVE THE REST OF THE INTRODUCER FROM THE PATIENT. NO PORTION WAS RETAINED. NO HARM AND NO INTERVENTION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22031931 ↗MalfunctionMar 14, 2023Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED BY THE CUSTOMER THAT "BLOOD RETURN NOTED ON FLOW SHEETS FOR MULTIPLE DAYS. NO TPA ADMINISTRATIONS OR POWER INJECTIONS NOTED IN CHART. PATIENT REQUIRED NO ADDITIONAL TREATMENT OR INTERVENTION ONCE LINE REMOVED. UPON REMOVAL, TEAR IN EXTERNAL PORTION OF THE LINE BETWEEN 35-40CM MARKINGS. THE TEAR SEEMS TO BE 5CM LONG."
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16542239 ↗MalfunctionNov 21, 2019Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT POWERPICC WAS FOUND LEAKING. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9354482 ↗MalfunctionNov 20, 2019Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT POWERPICC WAS FOUND LEAKING. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9349486 ↗MalfunctionApr 7, 2017Air Leak; Leak/Splash; Connection Problem
PER SALES REP, THE PRIMARY NURSE AT THE FACILITY STATED THE PICC LINE WAS LEAKING AT THE HUB TUBING CONNECTION. IT WAS REPORTED THAT THE RN NOTED AIR IN THE LINE WHEN TRYING TO DRAW BLOOD. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6474185 ↗
Other Catheter,intravascular,therapeutic,long-term greater than 30 days devices
- Groshong NXT ClearVue Catheter 7617405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,708 reports
- Groshong NXT ClearVue Catheter 7655405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 deaths1,536 reports
- PowerPICC Catheter 3174118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall402 reports
- L-Cath™ S/L PICC S/L 26GA (1.9F) x 30cmArgon Medical Devices, Inc. · Catheter,Intravascular,Therapeutic,Long-Term Greater Than 30 Days2 recalls245 reports
- PowerPICC SOLO2 Catheter 1194108DBard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days2 recalls216 reports
- Broviac 0600520Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days1 recall265 reports
- Groshong® Catheter 7717405Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days279 reports
- PowerPICC Catheter 3275118Bard Access Systems, Inc. · Catheter,intravascular,therapeutic,long-term greater than 30 days272 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.