MISSION 1810MSRecalls & reported problems

Bard Peripheral Vascular, Inc. · Mission Disposable Core Biopsy Instrument - 18Gx10cm · Class 2

All models of MISSION (20)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 00801741096983), received between Oct 17, 2023 and Feb 24, 2026 — classified as 8 malfunctions.

The most frequently reported specific device problem is “Difficult to Remove” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 3 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove5
  • Material Twisted/Bent5
  • Break1
  • Detachment of Device or Device Component1
  • Device Contamination with Chemical or Other Material1
  • Self-Activation or Keying1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 24, 2026Self-Activation or Keying

    ON (B)(6) 2026, A PATIENT UNDERWENT AN ULTRASOUND GUIDED KIDNEY BIOPSY PROCEDURE THROUGH NORMAL DENSITY TISSUE USING A MISSION INSTRUMENT. AFTER FIRING THE DEVICE, AN ISSUE OCCURRED WITH THE INSTRUMENTS LOCKING SYSTEM FOLLOWING PUSHING THE INNER NEEDLE TO RETRIEVE THE SPECIMEN. SLIGHT NEEDLE MOVEMENT OCCURRED CRUSHING THE SPECIMEN. IT WAS FURTHER REPORTED THAT, WITHOUT PRESSING THE TRIGGER BUTTON, THE OUTER CANNULA RELEASED FROM THE PRIME POSITION. THE PROCEDURE WAS COMPLETED BY ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24427087 ↗
  • MalfunctionSep 29, 2025Difficult to Remove; Material Twisted/Bent; Difficult to Remove; Material Twisted/Bent

    ON (B)(6) 2025, A PATIENT UNDERWENT AN ULTRASOUND GUIDED LYMPHATIC BIOPSY THROUGH NORMAL DENSITY TISSUE USING THE MISSION. DURING THE PROCEDURE, THE DEVICE NEEDLE WAS FOUND TO BE BENT. FURTHERMORE, IT WAS REPORTED THAT IT IS DIFFICULT TO REMOVE FROM A PATIENT. NO COAXIAL NEEDLE WAS USED, AND THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WERE NO REPORTED PATIENT INJURIES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23165330 ↗
  • MalfunctionSep 29, 2025Difficult to Remove; Material Twisted/Bent; Difficult to Remove; Material Twisted/Bent

    ON (B)(6) 2025, A PATIENT UNDERWENT AN ULTRASOUND GUIDED LYMPHATIC BIOPSY THROUGH NORMAL DENSITY TISSUE USING THE MISSION. DURING THE PROCEDURE, THE DEVICE NEEDLE WAS FOUND TO BE BENT. FURTHERMORE, IT WAS REPORTED THAT IT IS DIFFICULT TO REMOVE FROM A PATIENT. NO COAXIAL NEEDLE WAS USED, AND THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WERE NO REPORTED PATIENT INJURIES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23165328 ↗
  • MalfunctionSep 29, 2025Difficult to Remove; Material Twisted/Bent; Difficult to Remove; Material Twisted/Bent

    ON (B)(6) 2025, A PATIENT UNDERWENT AN ULTRASOUND GUIDE LYMPHATIC BIOPSY PROCEDURE VIA NORMAL DENSITY TISSUE USING THE MISSION. DURING THE PROCEDURE, THE DEVICE NEEDLE WAS FOUND TO BE BENT. FURTHER IT WAS REPORTED THAT DIFFICULT TO REMOVE FROM PATIENT. NO COAXIAL NEEDLE WAS USED. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23165052 ↗
  • MalfunctionJul 29, 2025Difficult to Remove; Material Twisted/Bent; Difficult to Remove; Material Twisted/Bent

    ON (B)(6) 2025 A PATIENT UNDERWENT AN ULTRASOUND GUIDED BREAST BIOPSY THROUGH HARD DENSITY TISSUE USING MISSION KIT. DURING THE PROCEDURE, THE NEEDLE WAS BENT AND DIFFICULT TO REMOVE FROM THE PATIENT. THE PROCEDURE WAS COMPLETED BY ANOTHER DEVICE. THERE WAS NO PATIENT REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22640141 ↗
  • MalfunctionJul 29, 2025Difficult to Remove; Material Twisted/Bent; Difficult to Remove; Material Twisted/Bent

    (B)(6) 2025 A PATIENT UNDERWENT AN ULTRASOUND GUIDED BREAST BIOPSY THROUGH HARD DENSITY TISSUE USING MISSION KIT. DURING THE PROCEDURE, THE NEEDLE WAS BENT AND DIFFICULT TO REMOVE FROM THE PATIENT. THE PROCEDURE WAS COMPLETED BY ANOTHER DEVICE. THERE WAS NO PATIENT REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22640133 ↗
  • MalfunctionAug 27, 2024Break; Device Contamination with Chemical or Other Material; Break; Device Contamination with Chemical or Other Material

    IT WAS REPORTED THAT DURING A BIOPSY PROCEDURE, A PLASTIC ALLEGEDLY COMES OUT FROM THE INSIDE OF THE PRODUCT. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20075251 ↗
  • MalfunctionOct 17, 2023Detachment of Device or Device Component; Detachment of Device or Device Component

    IT WAS REPORTED THAT DURING A BIOPSY PROCEDURE, THE DEVICE SPRING ALLEGEDLY CAME OUT WHILE PRIMING. THE PROCEDURE WAS COMPLETED WITH ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17947682 ↗

Other INSTRUMENT, BIOPSY devices

All INSTRUMENT, BIOPSY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page