Bard Peripheral Vascular, Inc. · TRUE™ DILATATION Balloon Valvuloplasty Catheter, 23 mm x 4.5 cm,110 cm catheter · Class 2

All models of TRUE DILATATION (10)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
10
Deaths reported
1
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 00801741097454), received between Mar 5, 2020 and Sep 15, 2026 — classified as 1 death, 1 injury, 8 malfunctions.

The most frequently reported specific device problem is “Difficult to Remove” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 2 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Remove4
  • Improper or Incorrect Procedure or Method2
  • Leak/Splash2
  • Material Rupture2
  • Adverse Event Without Identified Device or Use Problem1
  • Air/Gas in Device1
  • Deflation Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
  • Death1

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjurySep 15, 2026Difficult to Remove

    On (b)(6), 2026, a patient underwent a valvuloplasty procedure using a True Balloon Catheter. During the procedure, the balloon catheter could not be retracted into the sheath as intended, resulting in difficulty removing the sheath. To facilitate device retrieval, the balloon catheter was snared through a secondary sheath via contralateral femoral access and externalized through the left femoral access site. The balloon catheter was subsequently cut, and the remaining catheter shaft was extracted through the RFA sheath. The procedure was completed using another device. The patient's current status is unknown.

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 50766770 ↗
  • MalfunctionAug 4, 2026Difficult to Remove

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50126718 ↗
  • MalfunctionMay 23, 2026Difficult to Remove; Improper or Incorrect Procedure or Method

    A PATIENT UNDERWENT A VALVULOPLASTY PROCEDURE USING THE TRUE PTA BALLOON. IT WAS FURTHER DURING THE PROCEDURE, IT WAS DIFFICULT TO REMOVE THE BALLOON FROM THE INTRODUCER. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25264746 ↗
  • MalfunctionMay 21, 2026Difficult to Remove; Improper or Incorrect Procedure or Method

    ON (B)(6) 2026, A PATIENT UNDERWENT VALVULOPLASTY PROCEDURE USING THE TRUE PTA BALLOON. POST PROCEDURE, IT WAS DIFFICULT TO REMOVE THE BALLOON FROM THE INTRODUCER. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25239535 ↗
  • MalfunctionDec 26, 2025Deflation Problem; Air/Gas in Device; Deflation Problem; Air/Gas in Device

    ON (B)(6) 2025, A PATIENT UNDERWENT A VALVULOPLASTY PROCEDURE, IT WAS REPORTED THAT DURING THE PREPARATION OF A TRUE BALLOON, ALLEGEDLY FOUND IT COULD NOT BE DEFLATED. FURTHER, AIR BUBBLES WERE COMING OUT OF THE CATHETER ALL THE TIME. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23894831 ↗
  • MalfunctionDec 8, 2025Material Rupture; Material Rupture

    ON (B)(6) 2025, A PATIENT PREPPED FOR A PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA) PROCEDURE USING THE TRUE VALVULOPLASTY BALLOON CATHETER. PRIOR TO THE PROCEDURE, DURING PREPARATION, THE BALLOON CATHETER ALLEGEDLY RUPTURED. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23741364 ↗
  • MalfunctionAug 12, 2024Material Rupture; Material Rupture

    IT WAS REPORTED THAT DURING AN ANGIOPLASTY PROCEDURE, THE BALLOON ALLEGEDLY HAD A HOLE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19959148 ↗
  • MalfunctionJun 30, 2023Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT DURING A VALVULOPLASTY PROCEDURE, THE DEVICE ALLEGEDLY HAD LEAK AT 2 ATM. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO REPORTED PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17236505 ↗
  • MalfunctionFeb 22, 2022Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT PRIOR TO AN ANGIOPLASTY PROCEDURE, AIR WAS ALLEGEDLY FLOWING TO THE SYRINGE CONSTANTLY AS A RESULT IT WAS UNABLE TO CHECK THE BALLOON. THE PROCEDURE WAS COMPLETED USING ANOTHER DEVICE. THERE WAS NO PATIENT CONTACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13577348 ↗
  • DeathMar 5, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT FOLLOWING VALVULOPLASTY PROCEDURE, THE PATIENT EXPERIENCED LOSS OF CONSCIOUSNESS AND CARDIO-PULMONARY ARREST, WHICH REQUIRED CARDIOPULMONARY RESUSCITATION (CPR). IT WAS FURTHER REPORTED THAT AORTOGRAPHY CONFIRMED SEVERE AORTIC INSUFFICIENCY (AI), HOWEVER, AFTER IMPLANTATION OF BIOLOGIC AORTIC VALVE, VENTRICULAR FIBRILLATION (VF) WAS RESISTANT TO DEFIBRILLATION AND CPR. REPORTEDLY, THE PATIENT EXPIRED. THERE WAS NO DEVICE DEFICIENCY OR MALFUNCTION.

    Patient problems: Death

    MAUDE report 9794980 ↗

Other Balloon aortic valvuloplasty devices

All Balloon aortic valvuloplasty devices →