Proxis™ Ureteral Access Sheath 231245Recalls & reported problems
C. R. Bard, Inc. · Proxis™ Ureteral Access Sheath · Class 2
All models of Proxis Ureteral Access Sheath (9)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00801741101724), received between Oct 2, 2018 and Mar 21, 2026 — classified as 1 injury, 8 malfunctions.
The most frequently reported specific device problem is “Flaked” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Flaked3
- Device Contamination with Chemical or Other Material2
- Adverse Event Without Identified Device or Use Problem1
- Break1
- Detachment of Device or Device Component1
- Device Damaged Prior to Use1
- Material Integrity Problem1
- Material Separation1
Patient problems
- No Known Impact Or Consequence To Patient4
- No Clinical Signs, Symptoms or Conditions3
- No Consequences Or Impact To Patient3
- Foreign Body In Patient2
- Injury1
- No Patient Involvement1
- Patient Problem/Medical Problem1
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 21, 2026Flaked; Material Separation
IT WAS REPORTED THAT AFTER REMOVING THE DILATOR, THE SHEATH WAS PEELING LIKE A SPLINTER ON THE INSIDE OF THE SHEATH TIP, END POINT. PER FOLLOW UP INFORMATION RECEIVED VIA RCC ON 19MAR2026, STATED THAT RATHER THAN COMPLETE DETACHMENT, IT APPEARS TO BE A FRAYING OR SPLITTING CONDITION, THOUGH THE EXACT NATURE WAS UNCLEAR AND ITS USE WAS DISCONTINUED IMMEDIATELY UPON NOTICING THE ISSUE, SO THERE WERE NO RESIDUAL FRAGMENTS LEFT IN THE BODY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24656979 ↗MalfunctionFeb 7, 2023Flaked; Flaked
IT WAS REPORTED THAT THE INSIDE LINER OF PROXIS STARTED TO SHRED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16317278 ↗MalfunctionFeb 9, 2021Device Contamination with Chemical or Other Material; Scratched Material; Device Contamination with Chemical or Other Material; Scratched Material
IT WAS REPORTED THAT THE TRANSURETHRAL LITHOTRIPSY (TUL) IMPLEMENTATION CONFIRMED THAT THE LUMEN WAS SEEN LINT-LIKE UPON BLADDER STONE RETRIEVAL. PER ADDITIONAL INFORMATION RECEIVED VIA IBC ON 31JAN2021, THE FIBERS LIKE THREAD WERE ALLEGEDLY OBSERVED IN THE LUMEN.
Patient problems: Foreign Body In Patient
MAUDE report 11301620 ↗MalfunctionJan 26, 2021Flaked; Flaked
IT WAS REPORTED THAT A URETHRAL CATHETER SHEATH WAS INSERTED TO ESTABLISH ACCESS, WHEN PERFORMING LITHOTRIPSY UNDER FLEXIBLE URETEROSCOPE. IT WAS STATED THAT AFTER THE FLEXIBLE URETEROSCOPE WAS INSERTED, MATERIALS ON THE INNER WALL OF THE SHEATH CAME OFF.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 11229323 ↗InjuryDec 9, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem; Positioning Problem
IT WAS REPORTED THAT THE ACCESS SHEATH WAS NOT ABLE TO MOVE SMOOTHLY DURING THE PROCEDURE. THE USER REMOVED THE DEVICE TO FIND THE PATIENT HAD URETHRAL MUCOSAL DAMAGE. PER ADDITIONAL INFORMATION FROM THE IBC VIA EMAIL 25NOV2019, IT IS UNKNOWN IF THE PATIENT REQUIRED ANY FURTHER MEDICAL INTERVENTION, AND IT IS UNKNOWN THE CONDITION OF THE ACCESS SHEATH BEFORE THE PROCEDURE OCCURRED (WAS THE SHEATH SMOOTH, ROUGH, ETC.).
Patient problems: Injury; Patient Problem/Medical Problem
MAUDE report 9440115 ↗MalfunctionNov 11, 2019Device Contamination with Chemical or Other Material
IT WAS REPORTED THAT THERE WAS A LONG HAIR INSIDE OF THE SHEATH UPON OPENING THE PACKAGING.
Patient problems: No Known Impact Or Consequence To Patient; No Patient Involvement
MAUDE report 9305412 ↗MalfunctionJan 10, 2019Device Damaged Prior to Use; Material Integrity Problem; Device Damaged Prior to Use
IT WAS REPORTED THAT THERE WAS A BURR ON THE INNER CEASE. WHEN THE USER FOUND IT, THE SURGERY WAS COMPLETED AND NO ADDITIONAL DEVICE WAS USED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8233339 ↗MalfunctionNov 9, 2018Use of Device Problem; Use of Device Problem; Detachment of Device or Device Component
IT WAS REPORTED THAT WHILE EXTRACTING STONE THROUGH THE SHEATH, THE LINING ON THE INNER SHEATH SCRAPED AND A THIN STRAND FELL OFF INTO THE RENAL PELVIS. THIS PIECE WAS REMOVED BY THE STONE BASKET WITH NO INJURY TO THE PATIENT.
Patient problems: Foreign Body In Patient; No Known Impact Or Consequence To Patient
MAUDE report 8056929 ↗MalfunctionOct 2, 2018Break
IT WAS REPORTED THAT THE URETERAL ACCESS SHEATH CAME APART WHILE INSIDE OF THE PATIENT.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 7926652 ↗
Other endoscopic access overtube, gastroenterology-urology devices
- EVIS EXERA II SMALL INTESTINAL VIDEOSCOPE OLYMPUS SIF TYPE Q180Olympus Medical Systems Corp. · endoscopic access overtube, gastroenterology-urology1 recall42 reports
- Trokamed WA2PS20STROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall2 deaths2 reports
- Trokamed WA2PS20LTROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall2 deaths2 reports
- Trokamed WA2PS18LTROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall0 reports
- Trokamed WA2PS18STROKAMED GmbH · Endoscopic Access Overtube, Gastroenterology-Urology1 recall0 reports
- Navigator HD M0062502220Boston Scientific Corporation · endoscopic access overtube, gastroenterology-urology1 death31 reports
- Navigator HD M0062502230Boston Scientific Corporation · endoscopic access overtube, gastroenterology-urology29 reports
- Proxis™ Ureteral Access Sheath 231045C. R. Bard, Inc. · endoscopic access overtube, gastroenterology-urology22 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page