C. R. Bard, Inc. · Magic3 Go 6 Fr Pediatric Catheter with SureGrip · Class 2

All models of Magic3 Go Pediatric Catheter with SureGrip (3)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00801741136856), received between Apr 4, 2019 and Jun 23, 2025 — classified as 9 malfunctions.

The most frequently reported specific device problem is “Inadequacy of Device Shape and/or Size” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 2 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Inadequacy of Device Shape and/or Size2
  • Incorrect Measurement2
  • Component Misassembled1
  • Deformation Due to Compressive Stress1
  • Device Damaged Prior to Receipt by User1
  • Device Markings/Labelling Problem1
  • Difficult to Insert1
  • Fluid/Blood Leak1

Patient problems

  • No Consequences Or Impact To Patient6
  • No Known Impact Or Consequence To Patient5
  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 23, 2025Component Misassembled; Component Misassembled

    IT WAS REPORTED THAT ONE OF THE CATHETERS WERE IN A KNOT AND THE OTHER ONE WAS BROKEN IN HALF. PER CUSTOMER VIA PHONE ON 11JUN2025, IT WAS REPORTED THAT SOME OF THE CATHETERS HAD NO HOLES AT THE END, SOME WERE BROKEN, AND SOME WERE TWISTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22307114 ↗
  • MalfunctionMay 16, 2025Material Fragmentation; Material Fragmentation

    IT WAS REPORTED THAT ONE OF THE INTERMITTENT CATHETERS WERE IN A KNOT AND THE OTHER ONE WAS BROKEN IN HALF.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22034844 ↗
  • MalfunctionMay 16, 2025Deformation Due to Compressive Stress; Deformation Due to Compressive Stress

    IT WAS REPORTED THAT ONE OF THE INTERMITTENT CATHETERS WERE IN A KNOT AND THE OTHER ONE WAS BROKEN IN HALF. PER CUSTOMER VIA PHONE ON (B)(4) 2025, IT WAS REPORTED THAT SOME OF THE CATHETERS HAD NO HOLES AT THE END, SOME WERE BROKEN, AND SOME WERE TWISTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22034843 ↗
  • MalfunctionSep 23, 2020Device Damaged Prior to Receipt by User; Manufacturing, Packaging or Shipping Problem; Device Damaged Prior to Receipt by User

    IT WAS REPORTED THAT THE PACKAGES WERE MARKED WITH 6FR, BUT THE CATHETER INSIDE WAS 8FR.

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 10573430 ↗
  • MalfunctionMay 26, 2020Fluid/Blood Leak; Fluid/Blood Leak; Leak/Splash; Inadequacy of Device Shape and/or Size

    IT WAS REPORTED BY THE PATIENT'S MOTHER THAT THEY NEEDED A LARGER FRENCH SIZED CATHETER SINCE IT WAS LEAKING.

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 10088472 ↗
  • MalfunctionApr 4, 2020Inaccurate Flow Rate; Improper Flow or Infusion; Inaccurate Flow Rate

    IT WAS REPORTED THAT URINE DID NOT ALWAYS DRAIN FROM THE PATIENT'S BLADDER WITH USE OF THE CATHETER.

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 9925893 ↗
  • MalfunctionJul 18, 2019Difficult to Insert; Difficult to Insert

    IT WAS REPORTED DIFFICULT TO INSERT THE CATHETER AS IT WAS LARGER THAN USUAL. THE PATIENT WAS NOT ABLE TO FULLY INSERT THE CATHETER FOR USE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8804617 ↗
  • MalfunctionMay 8, 2019Incorrect Measurement; Device Markings/Labelling Problem; Incorrect Measurement

    IT WAS REPORTED THAT THE MAGIC 3 GO PEDIATRIC CATHETERS WERE LABELED 6 FRENCH, HOWEVER THE PATIENT ADVISED MANY WERE LARGER THAN THAT.

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 8593638 ↗
  • MalfunctionApr 4, 2019Incorrect Measurement; Inadequacy of Device Shape and/or Size; Incorrect Measurement

    IT WAS REPORTED THAT THE PEDIATRIC MAGIC 3 CATHETER WAS BIGGER THAN USUAL.

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient