Magic3 Go Pediatric Catheter with SureGripRecalls & reported problems across all models
C. R. Bard, Inc. · 3 models in the FDA device registry
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names at least one Magic3 Go Pediatric Catheter with SureGrip model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 27
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls
- 1
We found 3 models of Magic3 Go Pediatric Catheter with SureGrip by C. R. Bard, Inc. in the FDA's device registry (GUDID). Together they are named in 27 adverse event reports in the FDA's MAUDE database, received between Sep 14, 2018 and Oct 29, 2025 — classified as 3 injuries, 24 malfunctions.
The most frequently reported specific device problem is “Difficult to Insert” (4 reports).
1 FDA recall record name at least one of these models by its device identifier, 1 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Magic3 Go Pediatric Catheter with SureGrip recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Apr 20, 2023Class IIOpen, Classified
Some catheters had a manufacturing defect where the clear resealing label separating from the product foil pouch, resulting in a possible opening into the product packaging that could impact product sterility.
Z-1700-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗
Most reported Magic3 Go Pediatric Catheter with SureGrip problems
Device problems
- Difficult to Insert4
- Fluid/Blood Leak4
- Incorrect Measurement4
- Inadequacy of Device Shape and/or Size3
- Component Misassembled2
- Inadequate Instructions for Healthcare Professional2
- Insufficient Device Problem Information2
- Leak/Splash2
Patient problems
- No Consequences Or Impact To Patient12
- No Clinical Signs, Symptoms or Conditions11
- No Known Impact Or Consequence To Patient10
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available4
- Urinary Tract Infection3
- Burning Sensation2
- Hemorrhage/Blood Loss/Bleeding2
- Abrasion1
Magic3 Go Pediatric Catheter with SureGrip models
3 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Magic3 Go Pediatric Catheter with SureGrip 52810GCATHETER, STRAIGHT1 recall3 reports
- Magic3 Go Pediatric Catheter with SureGrip 52808GCATHETER, STRAIGHT15 reports
- Magic3 Go Pediatric Catheter with SureGrip 52806GCATHETER, STRAIGHT9 reports
Recent Magic3 Go Pediatric Catheter with SureGrip adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionOct 29, 2025Incorrect Measurement; Incorrect Measurement
IT WAS REPORTED THAT THE PATIENT SAID THE CATHETERS THEY RECEIVED WERE TOO LONG. NO MEDICAL INTERVENTION OR PATIENT IMPACT WAS REPORTED. NO ADDITIONAL INFORMATION PROVIDED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23415245 ↗MalfunctionJun 23, 2025Component Misassembled; Component Misassembled
IT WAS REPORTED THAT ONE OF THE CATHETERS WERE IN A KNOT AND THE OTHER ONE WAS BROKEN IN HALF. PER CUSTOMER VIA PHONE ON 11JUN2025, IT WAS REPORTED THAT SOME OF THE CATHETERS HAD NO HOLES AT THE END, SOME WERE BROKEN, AND SOME WERE TWISTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22307114 ↗MalfunctionMay 16, 2025Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT ONE OF THE INTERMITTENT CATHETERS WERE IN A KNOT AND THE OTHER ONE WAS BROKEN IN HALF.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22034844 ↗MalfunctionMay 16, 2025Deformation Due to Compressive Stress; Deformation Due to Compressive Stress
IT WAS REPORTED THAT ONE OF THE INTERMITTENT CATHETERS WERE IN A KNOT AND THE OTHER ONE WAS BROKEN IN HALF. PER CUSTOMER VIA PHONE ON (B)(4) 2025, IT WAS REPORTED THAT SOME OF THE CATHETERS HAD NO HOLES AT THE END, SOME WERE BROKEN, AND SOME WERE TWISTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22034843 ↗MalfunctionJul 27, 2023Improper Chemical Reaction; Improper Chemical Reaction
IT WAS REPORTED THAT THE PATIENT'S ADAPTATION TO THE MAGIC 3 (HYDROPHILIC) WAS VERY BAD AND COMPLAINTS WERE RECEIVED ON ACTIVATION AND LUBRICATION OF THE CATHETER. AS PER THE ADDITIONAL INFORMATION RECEIVED ON (B)(6) 2023 STATED THAT IT WAS NOT A DEFECT OR ANY DEVIATION FROM THE QUALITY OF THE PRODUCTS. THE PURPOSE OF THE REPORT WAS TO INFORM THAT DUE TO THE POOR MANUAL DEXTERITY OF MOST USERS (WHEELCHAIR USERS WITH SPINAL CORD INJURIES ¿ PARAPLEGICS AND QUADRIPLEGICS), THEY ENCOUNTERED DIFFICULTIES IN ACTIVATING THE HYDROPHILIC MAGIC3 CATHETER, FAILING TO PERFORM THE PROCEDURE, IN REGARDS TO A LIMITATION DUE TO THE CHARACTERISTIC OF THE PRODUCT AND NOT ANY MANUFACTURING DEFECT. AS PER THE ADDITIONAL INFORMATION RECEIVED ON (B)(6) 2023, THE CUSTOMER PROVIDED THE REASONS FOR DIFFICULTIES WITH ACTIVATION IN DETAIL AS FOLLOWS: AS PREVIOUSLY REPORTED, MANY OF THE USERS WERE QUADRIPLEGIC, THAT IS, FOR SOME REASON THEY HAD A HIGH SPINAL CORD INJURY COMPROMISING TOTALLY OR PARTIALLY THE MOVEMENTS OF THE UPPER LIMBS. IN THE CASE OF TOTAL LOSS, THERE WAS A NEED FOR ANOTHER PERSON TO PERFORM THE PROCEDURE. HOWEVER, OTHERS MANAGE, ALBEIT WITH A LOT OF EFFORT, TO PERFORM THE TWEEZING MOVEMENT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17404863 ↗InjuryJun 6, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE INTERMITTENT CATHETER POSSIBLY CAUSED URINARY TRACT INFECTION. IT TOOK PLACE A MONTH AGO AND HAD RECEIVED ANTIBIOTICS ABOUT 3 TIMES TO OVERCOME URINARY TRACT INFECTION. PER FOLLOW UP VIA PHONE ON (B)(6) 2023, IT WAS REPORTED THAT THE CUSTOMER RECEIVED A VOLUNTARY EMERGENCY NOTICE FROM BD REGARDING A RECALL FOR A NONCONFORMITY WITH THE MAGIC GO 14 FR CATHETERS. THEY WERE REPORTED IN A COMPANY-WIDE NOTICE AS HAVING NONSTERILE COUDE, AND THEY HAPPENED TO BE ONE OF THOSE IMPACTED BY IT. AT THE TIME, THEY WERE SENT OUT FROM 180 MEDICAL. THIS LED TO NUMEROUS BLADDER INFECTIONS AND SEPSIS, AND THIS MADE THINGS DIFFICULT FOR THEM AS THEY COULD NOT WALK. THEY STILL HAD SAMPLES AVAILABLE AND PROVIDED THE LOT# JUGW1445.
Patient problems: Sepsis; Unspecified Infection; Urinary Tract Infection
MAUDE report 17071263 ↗MalfunctionSep 1, 2022Component Misassembled; Component Misassembled
IT WAS REPORTED THAT THE EYELET END OF THE MAGIC 3 GO INTERMITTENT CATHETER WAS SKINNY AND HAD A CURVE TO THEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15342458 ↗MalfunctionSep 1, 2022Material Twisted/Bent; Material Twisted/Bent
IT WAS REPORTED THAT THE EYELET END OF THE MAGIC 3 GO INTERMITTENT CATHETER WAS SKINNY AND HAD A CURVE TO THEM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15335849 ↗MalfunctionAug 22, 2022Difficult to Insert; Sharp Edges; Difficult to Insert; Sharp Edges
IT WAS REPORTED THAT THE PATIENT COULD NOT USE INTERMITTENT CATHETER AND WHEN INSERTED THEY SCRAPED PATIENT. IT WAS STATED THAT THE INTERMITTENT CATHETER CAUSED A LOT OF BLEEDING AND PATIENT WAS USING 10 NOW. IT WAS STATED THAT THE DOCTOR WOULD SEND MEDICAL PRESCRIPTION. NO MEDICAL INTERVENTION WAS REPORTED.
Patient problems: Abrasion; Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 15265102 ↗InjuryAug 2, 2022Inadequacy of Device Shape and/or Size; Patient Device Interaction Problem; Inadequacy of Device Shape and/or Size; Patient Device Interaction Problem
IT WAS REPORTED THAT THE INTERMITTENT CATHETERS CAUSED THE PATIENT TO BLEED. PER FOLLOW UP INFORMATION RECEIVED VIA PHONE ON 19JUL2022, THE PATIENT WAS IN GOOD HEALTH AND FELT THE BLEEDING WAS CAUSED BY THE SIZE OF THE INTERMITTENT CATHETERS THAT WERE BEING USED. THE PATIENT WENT FROM USING A SIZE 8 DOWN TO A SIZE 5. THE SIZE 8 INTERMITTENT CATHETERS CAUSED THE PATIENT TO DEVELOP URINARY TRACT INFECTION (UTI) AND WAS PRESCRIBED AMOXICILLIN TO ALLEVIATE IT. ALSO USED SOAP AND WATER TO CLEAN THE AFFECTED AREA.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Urinary Tract Infection
MAUDE report 15148640 ↗MalfunctionApr 26, 2022Difficult to Insert; Insufficient Device Problem Information; Difficult to Insert; Insufficient Device Problem Information
IT WAS REPORTED THAT THE INTERMITTENT CATHETER WAS HARD TO USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14208143 ↗MalfunctionDec 28, 2021Incorrect Measurement; Incorrect Measurement
IT WAS REPORTED THAT WRONG LABEL WAS ATTACHED ON THE MAGIC 3 INTERMITTENT CATHETER. PER FOLLOW UP VIA EMAIL ON 29NOV2021, CUSTOMER STATED THAT THEY COULD FIND CATHETERS OF DIFFERENT SIZE IN THE BOX. THE BIGGEST CATHETERS CAUSED THE PATIENT TO EXPERIENCE BURNING AND BLEEDING SENSATION DURING THE PROCEDURE. NO MEDICAL INTERVENTION WAS REPORTED. PER FOLLOW UP VIA EMAIL ON 01DEC021, THE COMPLAINANT WAS NOT SATISFIED WITH THE DIAMETER OF THE CATHETER, LEADING TO THE PATIENT EXPERIENCING BLEEDING AND BURNING FEELING, AND ASSUMED IT MUST BE A DIFFERENT FRENCH SIZE THAN WHAT IS ON THE LABEL, WHICH LED TO THE ALLEGATION OF THE LABELING BEING WRONG. THE USER FELT THAT THE LABELING MUST BE INCORRECT SINCE THE FRENCH SIZE WAS NOT WHAT THEY EXPECTED. PER FOLLOW UP VIA EMAIL ON 03JAN022, THE ISSUE OCCURRED IN 2 UNITS FROM SAME LOT NUMBER JUFR2087.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Burning Sensation
MAUDE report 13093689 ↗MalfunctionDec 14, 2021Inadequate Instructions for Healthcare Professional; Illegible Information; Inadequate Instructions for Healthcare Professional; Illegible Information
IT WAS REPORTED THAT WRONG LABEL WAS ATTACHED TO THE MAGIC 3 INTERMITTENT CATHETER. PER FOLLOW UP VIA EMAIL ON 29NOV2021 THE CUSTOMER STATED THAT THEY COULD FIND THE CATHETERS OF DIFFERENT SIZE IN THE BOX. THE BIGGEST CATHETERS CAUSED THE PATIENT TO EXPERIENCE BURNING AND BLEEDING SENSATION DURING THE PROCEDURE. NO MEDICAL INTERVENTION WAS REPORTED. PER FOLLOW UP VIA EMAIL ON 01DEC2021 THE COMPLAINANT WAS NOT SATISFIED WITH THE DIAMETER OF THE CATHETER WHICH LEADS TO THE PATIENT TO EXPERIENCE BLEEDING AND BURNING FEELING AND ASSUMED IT MUST BE A DIFFERENT FRENCH SIZE THAN WHAT IS ON THE LABEL WHICH LEADS TO THE ALLEGATION OF THE LABELING BEING WRONG. THE USER FELT THAT THE LABELING MUST BE INCORRECT SINCE THE FRENCH SIZE WAS NOT WHAT THEY EXPECTED. PER FOLLOW UP VIA EMAIL ON 03JAN022, THE ISSUE OCCURRED IN 2 UNITS FROM SAME LOT NUMBER JUFR2087.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Burning Sensation; Hemorrhage/Blood Loss/Bleeding; No Clinical Signs, Symptoms or Conditions
MAUDE report 13003144 ↗MalfunctionApr 2, 2021Inadequate Instructions for Healthcare Professional; Insufficient Device Problem Information; Inadequate Instructions for Healthcare Professional; Insufficient Device Problem Information
IT WAS REPORTED THAT FROM THE PICS AND DESCRIPTION, THE USER SEEMS THAT DIFFERENT GAUGE OF THE CATHETERS WERE INTO THE PACKAGING . THEY FOUND THIS IN 10 UNITS THAT ARE NOT USED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11611077 ↗MalfunctionDec 21, 2020Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED THAT THE CATHETERS DID NOT WORK FOR THE PATIENT SINCE THE PATIENT EXPERIENCED A LEAK.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 11044467 ↗
Other C. R. Bard, Inc. products
- Bardex I.C. Foley Catheter26 models · 3,607 reports
- Bardex Lubricath Foley Catheter38 models · 1,670 reports · 1 recall
- Bardex Lubri-Sil I.C. All-Silicone Foley Catheter26 models · 1,518 reports
- Magic3 Coude Intermittent Catheter with Sure-Grip Sleeve5 models · 1,466 reports
- Magic3 Intermittent Catheter with Sure-Grip Sleeve14 models · 1,310 reports
- Bardia Foley Catheter Silicone Coated19 models · 1,283 reports
- PureWick Female External Catheter5 models · 1,184 reports
- Bardex All-Silicone Foley Catheter12 models · 1,170 reports
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page