Midline Catheter Kit P4153108DGRecalls & reported problems
Bard Access Systems, Inc. · 3Fr SL PowerMidline catheter Max Kit w/GuardIVa · Class 2
All models of Midline Catheter Kit (31)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00801741140952), received between Oct 22, 2024 and Oct 22, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fluid/Blood Leak1
Patient problems
- Extravasation1
- Swelling/ Edema1
- Unspecified Tissue Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 22, 2024Fluid/Blood Leak; Fluid/Blood Leak
IT WAS REPORTED LINE FRACTURE AND LEAKING DURING ADMINISTRATION OF OXALIPLATIN AT 12 CM CAUSED LINE TO BE REMOVED. PICC WAS 15 DAYS IN SITU. TRIM LENGTH 50 CM, 8 CM EXTERNAL, 42 CM INTERNAL. INSERTED IN RIGHT BASILIC VEIN. PATIENT REPORTED THAT PICC WAS LEAKING DURING ADMINISTRATION OF OXALIPLATIN. THE LEAK OCCURRED INSIDE THE SKIN OF THE PATIENT WITH INFILTRATION/EXTRAVASATION OF THE FLUID IN THE PATIENT¿S TISSUE AND COMING OUT THROUGH THE EXIT SITE OF THE PICC. PATIENT EXPERIENCED, SWELLING, OEDEMA AND PAIN. (25 % OXALIPLATIN INFUSION HAD BEEN ADMINISTERED WHEN EVENT HAPPENED). EXTRAVASATION OF OXALIPLATIN OCCURRED. PICC WAS REMOVED AND FRACTURE OF THE LINE WAS SEEN AT 12 CM MARK OF THE CATHETER. PATIENT HAD TO GO THROUGH EXTRAVASATION PATHWAY. SWELLING, PAIN, OEDEMA AN TISSUE INJURY OCCURRED. PATIENT COULD NOT COMPLETE HER CHEMOTHERAPY CYCLE WHICH WAS DELAYED. PATIENT WILL NEED A NEW PICC INSERTED TO RESUME THEIR ANTICANCER TREATMENT. NO OTHER INFORMATION WAS PROVIDED.
Patient problems: Extravasation; Swelling/ Edema; Unspecified Tissue Injury
MAUDE report 20509866 ↗
Other Midline catheter devices
- Midline Catheter Kit P4154108DBard Access Systems, Inc. · Midline catheter1 recall1 death126 reports
- ARROW IPN921959Teleflex Incorporated · Midline catheter2 recalls0 reports
- Midline Catheter Kit S4153108BDPBard Access Systems, Inc. · Midline catheter1 recall36 reports
- Midline Catheter Kit S4153108DBard Access Systems, Inc. · Midline catheter1 recall32 reports
- Midline Catheter Kit S4153108DGPBard Access Systems, Inc. · Midline catheter1 recall15 reports
- Midline Catheter Kit S4254108BDPBard Access Systems, Inc. · Midline catheter1 recall11 reports
- Midline Catheter Kit P4154108Bard Access Systems, Inc. · Midline catheter1 recall10 reports
- ARROW IPN037698Teleflex Incorporated · Midline catheter1 recall9 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page