Skip to content

Handicare 323101Recalls & reported problems

Handicare USA, Inc. · C450 Manual Traverse - Quick Curve · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810045510453), received between Jul 26, 2023 and Jul 26, 2023 — classified as 1 injury.

The most frequently reported specific device problem is “Component Misassembled” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Component Misassembled1
  • Component Missing1

Patient problems

  • Abrasion1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 26, 2023Component Missing; Component Misassembled; Component Missing; Component Misassembled

    MOTOR CAME OUT OF THE END OF THE TRACK WHEN THE CARE AID WAS RETURNING THE MOTOR TO THE DOCKING STATION. THE MOTOR HIT THE CARE AID CAUSING BRUISING ON THE BACK OF RIGHT HAND AND KNEE, NO HOSPITALIZATION. EMPLOYEE PUT ICE ON THE AREA AND WAS ABLE TO KEEP WORKING FOR HER ENTIRE SHIFT. UPON INSPECTION OF THE TRACK, THERE WERE NO SAFETY PINS INSTALLED.

    Patient problems: Abrasion

    MAUDE report 17402284 ↗

FDA clearance and classification

The FDA regulates product code FSA (lift, patient, non-ac-powered) under 21 CFR 880.5510 as a Class I device. 21 CFR 880.5510 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Handicare 323101

Has the Handicare 323101 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00810045510453), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Handicare 323101?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 26, 2023. That report lists device problems “Component Misassembled” (1) and “Component Missing” (1); patient problem “Abrasion” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Handicare 323101?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Handicare 323101 FDA approved?

Devices of this type (product code FSA) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Handicare USA, Inc.

Who makes the Handicare 323101, and is it still sold?

The FDA's device database lists Handicare USA, Inc. as the company responsible for it (brand Handicare, model 323101). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Lift, Patient, Non-Ac-Powered devices

All Lift, Patient, Non-Ac-Powered devices →

Sources and updates