8.0 X 165mm Cann Screw Fastener Full Thd 380-5165-001Recalls & reported problems
Osteocentric Technologies, Inc. · 8.0 X 165mm Cann Screw Fastener Full Thd · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810074306720), received between May 22, 2025 and May 22, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 22, 2025Break; Break
DR. (B)(6) PERFORMED A REVISION SURGERY AT (B)(6) HOSPITAL TO ADDRESS A BROKEN 8.0MM FULLY THREADED PELVIC SCREW MANUFACTURED BY A COMPANY OTHER THAN OSTEOCENTRIC. THE SURGICAL TEAM BEGAN BY REMOVING THE DAMAGED SCREW. THEY ATTEMPTED TO PLACE AN OSTEOCENTRIC 8.0 X 165MM CAN SCREW FASTENER FULL THD, USING THE SAME PATH. HOWEVER, THEY WERE UNABLE TO FULLY SEAT THE FASTENER. THE FASTENER BECAME BENT, AND THE K-WIRE SNAPPED DURING REMOVAL. THE SYSTEM INCLUDES A TAP FOR USE IN DENSE BONE, HOWEVER IT WAS NOT USED IN THIS INSTANCE. THE SECOND ATTEMPT WITH ANOTHER OSTEOCENTRIC 8.0 X 165MM CANN SCREW FASTENER FULL THD THEY TRIED PLACING THE FASTENER, AND THIS TIME DRILLED AND TAPPED THE BONE TO REDUCE RESISTANCE. DESPITE THAT, THERE WAS STILL ENOUGH RESISTANCE NEAR THE END THAT THE FASTENER HEAD SNAPPED OFF WHEN ATTEMPTING TO SEAT IT AT THE ILIAC CREST. AFTER REMOVING THE BROKEN FASTENER, THE SURGEON RE-DRILLED AND TAPPED AGAIN, AND WAS THEN ABLE TO SUCCESSFULLY PLACE AN OSTEOCENTRIC 170MM, 8.0MM CANNULATED FASTENER. THERE WAS NO HARM TO THE PATIENT. THE BENT AND BROKEN FASTENER AND K-WIRE WERE FULLY REMOVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22073586 ↗
Other Screw, Fixation, Bone devices
- NA 03.043.029Synthes GmbH · Screw, fixation, bone503 reports
- OSTEORAPTOR 72201995Smith & Nephew, Inc. · Screw, fixation, bone253 reports
- Control 360 SK12Treace Medical Concepts, Inc. · Screw, Fixation, Bone195 reports
- HEALIX PEEK ORTHOCORD 222205Medos International Sàrl · Screw, fixation, bone186 reports
- PRECICE® Bone Transport System STP3.5-400Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-225Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-350Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
- PRECICE® Bone Transport System STP3.5-300Nuvasive Specialized Orthopedics, Inc. · Screw, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.