TriLeap Lower Extremity Anatomic Plating System NC Ti Fusion 5 hole, Long, RightRecalls & reported problems
Crossroads Extremity Systems · NC Ti Fusion 5 hole, Long, Right · Class 2 · Implant
All models of TriLeap Lower Extremity Anatomic Plating System (57)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00810112596007), received between Mar 11, 2025 and Mar 11, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Crack” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Crack1
- Improper or Incorrect Procedure or Method1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 11, 2025Crack; Improper or Incorrect Procedure or Method; Crack; Improper or Incorrect Procedure or Method
IT WAS REPORTED THAT WHEN INSERTING A SCREW INTO THE PLATE AFTER CONTOURING, THE PLATE WAS CRACKED AND THE SCREW WENT UNDERNEATH THE PLATE. THE PLATE WAS USED FOR AN NC FUSION TO ADDRESS ARTHRITIS ¿ NO DEFORMITY. THE DOCTOR NEEDED TO CONTOUR THE PLATE TO BRING THE PLATE CLOSER TO THE MEDIAL CUNEIFORM. HE CONTOURED THE PLATE USING BENDING PLIERS, CHECKED THE FIT, FOUND HE OVER BENT THE PLATE, THEN BENT IT IN THE REVERSE DIRECTION TO GET THE FIT HE WANTED. THERE WAS NO SURGICAL DELAY OR PATIENT CONSEQUENCE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO ADDITIONAL MEDICAL INTERVENTION WAS REQUIRED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21575519 ↗
Other Plate, Fixation, Bone devices
- Lapiplasty System 2 SK14Treace Medical Concepts, Inc. · Plate, Fixation, Bone260 reports
- PRECICE® Plating System LP4.5-PRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls6 reports
- PRECICE® Plating System LP4.5-MLT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls5 reports
- PRECICE® Plating System LP4.5-MRT4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-PLF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls3 reports
- PRECICE® Plating System LP4.5-DRF4BNuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls1 report
- PRECICE® Plating System LP4.5-MLT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
- PRECICE® Plating System LP4.5-MRT42Nuvasive Specialized Orthopedics, Inc. · Plate, Fixation, Bone3 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page