Azur Detachable Helical HydroCoil 45-480815Recalls & reported problems
Microvention, Inc. · Azur · Class 2 · Implant
All models of Azur Detachable Helical HydroCoil (42)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00810170017971), received between Aug 31, 2018 and Nov 4, 2021 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component3
- Device-Device Incompatibility1
- Migration1
- Premature Separation1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 4, 2021Premature Separation; Premature Separation
IT WAS REPORTED THAT THE EMBOLIZATION COIL DETACHED WITHIN THE MICROCATHETER. A NEW COIL WAS USED TO COMPLETE THE PROCEDURE SUCCESSFULLY AND AS INTENDED. NO HARM OR SEQUELAE WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12755291 ↗MalfunctionJul 21, 2021Detachment of Device or Device Component; Device-Device Incompatibility; Detachment of Device or Device Component; Device-Device Incompatibility
IT WAS REPORTED THAT DURING EMBOLIZATION OF A SPLENIC ARTERY EMBOLIZATION, THE PHYSICIAN ENCOUNTERED RESISTANCE DURING ADVANCEMENT. UPON RETRACTION, THE COIL HAD DETACHED. THE COIL WAS REMOVED WITHOUT INTERVENTION. THERE WAS NO REPORTED PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12207978 ↗MalfunctionJun 2, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING TREATMENT OF A SPLENIC ARTERY ANEURYSM EMBOLIZATION, ACCESS ACHIEVED INTO SPLENIC ANEURYSM AND SUCCESSFULLY DELIVERED MULTIPLE EMBOLIZATION COILS. AN AZUR 45-480815 WAS INTRODUCED. THE COIL ADVANCED WITHOUT ISSUE TO DISTAL PORTION OF MICROCATHETER. ABOUT 1CM OF COIL WAS ADVANCED OUT OF MICROCATHETER BEFORE MICROCATHETER KICKED BACK. COIL RETRACTED AND RE-ADVANCED MULTIPLE TIMES TO ALLOW COIL TO SOFTEN. THE COIL BECAME STUCK AND WOULD NOT ADVANCE FURTHER. DURING ATTEMPT TO WITHDRAW THE COIL, IT DETACHED IN MICROCATHETER. MICROCATHETER AND COIL WERE REMOVED TOGETHER SUCCESSFULLY. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH ADDITIONAL COILS. NO PATIENT HARM OR INTERVENTION WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11926002 ↗InjurySep 27, 2018Migration; Migration
IT WAS REPORTED THAT NINE (9) COILS WERE IMPLANTED IN AN ARTERIOVENOUS (AV) FISTULA OFF THE RIGHT ILIAC ARTERY IN (B)(6) 2018. APPROXIMATELY THREE (3) MONTHS LATER IN (B)(6) THE PATIENT HAD SYMPTOMATIC COMPLAINTS IN HER PELVIS AGAIN. ANGIOGRAPHIC EXAMINATION REVEALED THE COIL PACK WAS NO LONGER IN THE AREA OF THE AV FISTULA, AND HAD MIGRATED TO THE PATIENT'S LUNG. ATTEMPTS WERE MADE TO RETRIEVE THE COIL PACK OVER A PERIOD OF 1.5 HOURS; HOWEVER, THEY WERE UNSUCCESSFUL. THE PATIENT HAS HAD NO SYMPTOMS OF COMPLICATIONS IN THE RESPIRATORY SYSTEM. THE PATIENT HAS BEEN REFERRED TO A CT SURGEON. THE PATIENT IS CURRENTLY REPORTED TO BE STABLE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7916753 ↗MalfunctionAug 31, 2018Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT DURING POSITIONING OF AN EMBOLIZATION COIL, THE COIL DETACHED FROM THE PUSHER WHILE BEING RETRACTED. THE COIL WAS REMOVED IN ITS ENTIRETY TOGETHER WITH THE CATHETER. THERE WAS NO REPORTED PATIENT INJURY OR INTERVENTION. THE PATIENT WAS REPORTED TO BE STABLE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7840098 ↗
Other Device, Neurovascular Embolization devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page